Panasonic CU-5E36QBU Disassembly and Assembly Instructions, Outdoor Unit Removal Procedure

Page 34

16. Disassembly and Assembly Instructions

WARNING

High voltages are generated in the electrical parts area by the capacitor. Ensure that the capacitor has discharged sufficiently before proceeding with repair work. Failure to heed this caution may result in electric shocks.

16.1 Outdoor Unit Removal Procedure

Caution! When handling electronic controller, be careful of electrostatic discharge.

16.1.1Removing the Cabinet Top Plate

1.Remove the cabinet top plate (remove the 11 screws).

Fig. 1

16.1.2Remove the Control Board Cover and Particular Plates

2.Remove the control board cover (remove the 5 screws).

Fig. 2

34

Image 34
Contents Air Conditioner Outdoor Unit Destination CanadaTable of Contents Safety Precautions Page Specifications Outdoor UnitOutdoor Unit ∙ Multi Split Combination Possibility Room Indoor Unit Capacity Total Indoor Dimensions Refrigeration Cycle Diagram Block Diagram Wiring Electronic Controller Noise FilterElectronic Circuit Diagram Printed Circuit Board Main Printed Circuit BoardPage Installation Information Check PointsInstallation Instruction Select The Best LocationInstall The Outdoor Unit Connect The PipingEvacuation Of The Equipment Cutting and Flaring the PipingConnect The Cable To The Outdoor Unit Heat InsulationDisposal Of Outdoor Unit Drain Water Cooling Operation Cooling Powerful OperationOperation Control Outdoor fan controlHeating Operation Powerful OperationHeating Room Temp Sampling Control Simultaneous Operation Control Protection Control Electronic Parts Temperature Rise Protection 1 CoolElectronic Parts Temperature Rise Protection 2 Cool Freeze Prevention control CoolCooling overload control Cool Heating overload control HeatDeice Control Time Delay Safety Control Restart ControlIPM power transistor Protection Control 13.10 30 seconds Force OperationValve close detection control Compressor Protection Control Gas leak detection controlCompressor discharge high pressure protection control Pump down operation SW1 Servicing ModeTest Run Operation Mode priority function Wiring Error CheckPower Save Mode Cooling only functionTroubleshooting Guide Self Diagnosis FunctionPage Page Removing the Cabinet Top Plate Disassembly and Assembly InstructionsOutdoor Unit Removal Procedure Remove the Control Board Cover and Particular PlatesRemoving the Cabinet Front Plate Removing the Control P.C. Board Removing the Propeller Fan and Fan MotorOperation Characteristics Technical DataOne Indoor Unit Operation Page Page Page Page Page Page Page Two Indoor Unit Operation Page Page Page Page Page Page Page Page Page Page Page Three Indoor Unit Operation Page Page Page Page Page Page Page Four Indoor Unit Operation Page Five Indoor Unit Operation Page Exploded View and Replacement Parts List Safety REF.NO Description & Name QTY CU-5E36QBU Remark Installation Instruction