Panasonic CU-5E36QBU service manual Outdoor Unit

Page 6

 

Item

Unit

 

 

OUTDOOR UNIT

 

 

 

 

 

 

 

 

 

 

 

 

 

Dry Bulb

 

Wet Bulb

 

 

 

 

 

 

 

 

 

Cooling

Maximum

°C (°F)

32 (89.6)

 

23 (73.4)

 

 

 

 

 

 

 

Indoor Operation Range

Minimum

°C (°F)

16 (60.8)

 

11 (51.8)

 

 

 

 

 

 

 

 

 

Heating

Maximum

°C (°F)

30 (86.0)

 

 

 

 

 

 

 

 

 

 

 

Minimum

°C (°F)

16 (60.8)

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

Maximum

°C (°F)

46 (114.8)

 

26 (78.8)

 

 

 

 

 

 

 

Outdoor Operation Range

Minimum

°C (°F)

-10 (14.0)

 

 

 

 

 

 

 

 

 

 

Heating

Maximum

°C (°F)

24 (75.2)

 

18 (64.4)

 

 

 

 

 

 

 

 

 

 

Minimum

°C (°F)

-15 (5.0)

 

-16 (3.2)

 

 

 

 

 

 

 

 

 

 

 

Note

Specifications are subject to change without notice for further improvement.

6

Image 6
Contents Air Conditioner Outdoor Unit Destination CanadaTable of Contents Safety Precautions Page Specifications Outdoor UnitOutdoor Unit ∙ Multi Split Combination Possibility Room Indoor Unit Capacity Total Indoor Dimensions Refrigeration Cycle Diagram Block Diagram Wiring Electronic Controller Noise FilterElectronic Circuit Diagram Printed Circuit Board Main Printed Circuit BoardPage Installation Information Check PointsInstallation Instruction Select The Best LocationInstall The Outdoor Unit Connect The PipingEvacuation Of The Equipment Cutting and Flaring the PipingConnect The Cable To The Outdoor Unit Heat InsulationDisposal Of Outdoor Unit Drain Water Cooling Operation Cooling Powerful OperationOperation Control Outdoor fan controlPowerful Operation Heating OperationHeating Room Temp Sampling Control Simultaneous Operation Control Protection Control Electronic Parts Temperature Rise Protection 1 CoolElectronic Parts Temperature Rise Protection 2 Cool Freeze Prevention control CoolCooling overload control Cool Heating overload control HeatDeice Control Time Delay Safety Control Restart ControlIPM power transistor Protection Control 13.10 30 seconds Force OperationCompressor Protection Control Gas leak detection control Valve close detection controlCompressor discharge high pressure protection control Servicing Mode Pump down operation SW1Test Run Operation Mode priority function Wiring Error CheckPower Save Mode Cooling only functionTroubleshooting Guide Self Diagnosis FunctionPage Page Removing the Cabinet Top Plate Disassembly and Assembly InstructionsOutdoor Unit Removal Procedure Remove the Control Board Cover and Particular PlatesRemoving the Cabinet Front Plate Removing the Control P.C. Board Removing the Propeller Fan and Fan MotorTechnical Data Operation CharacteristicsOne Indoor Unit Operation Page Page Page Page Page Page Page Two Indoor Unit Operation Page Page Page Page Page Page Page Page Page Page Page Three Indoor Unit Operation Page Page Page Page Page Page Page Four Indoor Unit Operation Page Five Indoor Unit Operation Page Exploded View and Replacement Parts List Safety REF.NO Description & Name QTY CU-5E36QBU Remark Installation Instruction