Panasonic CU-5E36QBU service manual Specifications, Outdoor Unit

Page 5

2. Specifications

 

Item

 

Unit

OUTDOOR UNIT

 

 

 

 

 

Indoor Unit Combination

 

 

 

2.0kW + 2.0kW + 2.0kW + 2.0kW + 2.5kW

 

 

 

 

 

Power Source

 

 

 

1 Phase, 208-230V, 60Hz (Power supply from outdoor unit)

 

 

 

 

 

 

Capacity

 

kW

10.56 (2.9 ~ 11.5)

 

 

 

 

 

 

BTU/h

36000 (9900 ~ 39000)

 

 

 

 

 

 

 

 

 

Electrical

Running Current

A

19.0 - 17.2

 

 

 

 

Cooling Operation

Power Input

kW

3.75 (0.55 ~ 3.86)

Data

 

 

 

 

 

 

EER

W/W

2.82 (5.27 ~ 2.98)

 

 

 

 

 

 

Noise

Sound Pressure Level

dB-A (H/L)

55 / -

 

 

 

 

 

Sound Power Level

dB (H/L)

71 / -

 

 

 

 

 

 

 

 

Capacity

 

kW

11.1 (3.4 ~ 14.5)

 

 

 

 

 

 

BTU/h

37800 (11600 ~ 49500)

 

 

 

 

 

 

 

 

 

Electrical

Running Current

A

14.8 - 13.4

 

 

 

 

Heating Operation

Power Input

kW

2.90 (0.53 ~ 4.24)

Data

 

 

 

 

 

 

COP

W/W

3.82 (6.42 ~ 3.42)

 

 

 

 

 

 

Noise

Sound Pressure Level

dB-A (H/L)

55 / -

 

 

 

 

 

Sound Power Level

dB (H/L)

71 / -

 

 

 

 

 

 

 

Maximum Current

 

 

A

21.3

 

 

 

 

 

Starting Current

 

 

A

19.0

 

 

 

 

 

Circuit Breaker Capacity

 

 

A

30

 

 

 

 

 

 

Height

 

mm (inch)

999 (39-11/32)

 

 

 

 

 

Dimension

Width

 

mm (inch)

940 (37-1/32)

 

 

 

 

 

 

Depth

 

mm (inch)

340 (13-13/32)

 

 

 

 

 

Net Weight

 

 

kg (lb)

83 (183)

 

 

 

 

 

Connection Cable

 

 

 

3 + 1 (Earth) min AWG16

 

 

 

 

 

Pipe Length Range (1 room)

 

 

m (ft)

3 ~ 25 (9.8 ~ 82.0)

 

 

 

 

Maximum Pipe Length (Total Room)

 

m (ft)

80 (262.4)

 

 

 

 

 

Refrigerant Pipe Diameter

Liquid Side

 

mm (inch)

6.35 (1/4)

 

 

 

 

Gas Side

 

mm (inch)

9.52 (3/8), (E24: 12.70 (1/2))

 

 

 

 

 

 

 

 

Type

 

 

Hermetic Motor / Rotary

 

 

 

 

 

Compressor

Motor Type

 

 

Brushless (4-poles)

 

 

 

 

 

 

Rated Output

 

W

1.30k

 

 

 

 

 

 

Type

 

 

Propeller Fan

 

 

 

 

 

Air Circulation

Motor Type

 

 

DC Motor (8-poles)

 

 

 

 

 

 

Rated Output

 

W

90

 

 

 

 

Fan Speed

High (Cooling / Heating)

RPM

750 / 740

 

 

 

 

 

 

Type

 

 

Plate fin configuration forced draft type

 

 

 

 

 

Tube Material

 

Copper

 

 

 

 

 

Heat Exchanger

Fin Material

 

 

Aluminum (Blue Coated)

 

 

 

 

 

 

Row / Stage

 

 

2 / 46

 

 

 

 

 

 

FPI

 

 

19

 

 

 

 

 

Air Volume

High (Cooling / Heating)

m3/min

71.2 (2512) / 70.1 (2475)

(ft3/min)

Refrigerant Control Device

 

 

 

Expansion Valve

 

 

 

 

 

Refrigerant Oil

 

 

 

FV50S

 

 

 

 

 

Refrigerant (R410A)

 

 

g (oz)

3.40k (120)

 

 

 

 

 

5

Image 5
Contents Destination Canada Air Conditioner Outdoor UnitTable of Contents Safety Precautions Page Outdoor Unit SpecificationsOutdoor Unit ∙ Multi Split Combination Possibility Room Indoor Unit Capacity Total Indoor Dimensions Refrigeration Cycle Diagram Block Diagram Electronic Controller Noise Filter WiringElectronic Circuit Diagram Main Printed Circuit Board Printed Circuit BoardPage Check Points Installation InformationSelect The Best Location Installation InstructionConnect The Piping Install The Outdoor UnitCutting and Flaring the Piping Evacuation Of The EquipmentHeat Insulation Connect The Cable To The Outdoor UnitDisposal Of Outdoor Unit Drain Water Operation Control Cooling Powerful OperationCooling Operation Outdoor fan controlHeating Room Temp Sampling Control Powerful OperationHeating Operation Simultaneous Operation Control Electronic Parts Temperature Rise Protection 2 Cool Electronic Parts Temperature Rise Protection 1 CoolProtection Control Freeze Prevention control CoolHeating overload control Heat Cooling overload control CoolIPM power transistor Protection Control Time Delay Safety Control Restart ControlDeice Control 13.10 30 seconds Force OperationCompressor discharge high pressure protection control Compressor Protection Control Gas leak detection controlValve close detection control Test Run Operation Servicing ModePump down operation SW1 Power Save Mode Wiring Error CheckMode priority function Cooling only functionSelf Diagnosis Function Troubleshooting GuidePage Page Outdoor Unit Removal Procedure Disassembly and Assembly InstructionsRemoving the Cabinet Top Plate Remove the Control Board Cover and Particular PlatesRemoving the Cabinet Front Plate Removing the Propeller Fan and Fan Motor Removing the Control P.C. BoardOne Indoor Unit Operation Technical DataOperation Characteristics Page Page Page Page Page Page Page Two Indoor Unit Operation Page Page Page Page Page Page Page Page Page Page Page Three Indoor Unit Operation Page Page Page Page Page Page Page Four Indoor Unit Operation Page Five Indoor Unit Operation Page Exploded View and Replacement Parts List Safety REF.NO Description & Name QTY CU-5E36QBU Remark Installation Instruction