SECTION 11—BATTERIES
Disconnecting Battery Cables
WARNING
The use of rubber gloves is recommended when working with batteries.
NEVER allow any of your tools and/or battery cables to contact both battery terminals at the same time. An electrical short may occur and serious personal injury or damage may occur.
NOTE: For this procedure, refer to FIGURE 11.3 on page 65.
1.Remove the seat. Perform one of the following:
•Van Seat ‐ Refer to Removing/Installing the Seat Assembly on page 48.
•ASBA Seat ‐ Refer to Removing/Installing the Seat Assembly on page 57.
2.Remove the batteries. Refer to Removing/Installing Batteries from/into Battery Tray on page 61.
3.Cut the tie‐wrap that secures the battery terminal cap in place (Detail “B” of FIGURE 11.3).
4.Slide terminal caps up onto the battery cables (FIGURE 11.3).
5.Disconnect POSITIVE (+) battery cable from the POSITIVE (+) battery terminal (FIGURE 11.3).
6.Disconnect NEGATIVE (‐) battery cable from NEGATIVE (‐) battery terminal (FIGURE 11.3).
Charging Batteries
WARNING
NEVER attempt to recharge the batteries by attaching cables directly to the battery terminals.
DO NOT attempt to recharge the batteries and operate the wheelchair at the same time.
DO NOT attempt to recharge the batteries when the wheelchair has been exposed to any type of moisture.
DO NOT attempt to recharge the batteries when the wheelchair is outside. DO NOT sit in the wheelchair while recharging the batteries.
DO NOT attempt to recharge the batteries using both the
Read and carefully follow the individual instructions for each charger (supplied or purchased). If charging instructions are not supplied, consult a qualified technician for proper procedures.
Pronto® M51™and M61™with SureStep® | 66 | Part No 1125085 |