OPERATOR ACTION | DISPLAY |
Turn the scale on. While “START” is displayed on the LCD (for 3 seconds) | “CAL” will appear on the LCD |
press the |
|
|
|
Press “ENTER” | Enter load weight “Load/200.0” |
|
|
Press “ENTER” to calibrate with 200 lb. This can be changed if desired. | “CLEAR” |
To change the calibration weight, press the BMI key. Then, use the arrow keys to change the value of the flashing digit. |
|
Use the BMI key to advance to the next digit, and again use the arrow keys to change the digit to the desired value. |
|
Repeat until you have entered the desired calibration weight. Press “ENTER” |
|
The calibration weight must be no less than 100 lb (45 kg) and no more than 300 lb (135 kg). |
|
|
|
Clear the weight from the platform and press “ENTER” | Zero Calibration |
Wait without touching or shaking the scale until the zero calibration | Weight calibration “Put XXX.X” |
process is finished |
|
Load the platform with the required weight and press “ENTER” | Weight calibration |
|
|
Wait without touching or shaking the scale until the zero calibration process is finished. | Calibration “Factor X.XXXX” |
Note: If the calibration is done in lb, the factor value you should have is |
|
0.9000 – 1.000 If the calibration is done in kg, the factor value should be |
|
0.4000 – 0.4250. If the factor value is different repeat the calibration procedure. |
|
|
|
Press ENTER | “DONE”/“CLEAR”/XXX |
Remove weight from the platform | Rebooting, please wait |
Wait until the scale resumes normal operation | “0.0” |
|
|
Exploded View of Scale
6