A&D GH-120/GH-200/GH-300/GH-202/GH-252 manual Data Format Examples, Stable Unstable Overload

Page 44

10.6.Data Format Examples

Stable

Unstable

Overload

Positive error

Overload

Negative error

A&D

 

S

 

T

 

,

 

+

 

 

0

0

0

.

 

1

 

2

 

7

8

 

 

 

 

 

 

 

 

 

 

 

g

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

DP

W

T

 

 

 

 

 

 

 

 

+

0

.

1

2

7

8

 

 

 

 

 

 

 

 

 

 

 

g

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KF

+

 

 

 

 

 

 

 

 

 

 

0

.

1

2

7

8

 

 

 

 

 

g

 

 

 

 

 

 

 

 

 

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MT

S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

.

1

 

2

 

7

8

 

 

 

 

 

 

 

g

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NU

+

0

0

0

0

.

1

2

7

 

8

 

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A&D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U

 

S

 

,

 

-

 

 

0

 

 

1

 

 

8

 

.

 

3

 

6

 

9

 

0

 

 

 

 

 

 

 

 

 

 

 

g

CR

 

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DP

U

 

S

 

 

 

 

 

 

 

 

 

 

 

-

 

 

1

 

8

 

.

 

3

 

6

 

9

 

0

 

 

 

 

 

 

 

 

 

 

 

g

 

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

KF

-

 

 

 

 

 

 

 

1

 

 

8

 

 

 

 

 

 

3

 

6

 

9

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MT

 

S

 

D

 

 

 

 

 

 

-

 

 

 

 

 

 

8

 

.

 

3

 

6

 

 

 

 

 

0

 

 

 

 

 

 

 

g

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NU

-

 

0

 

0

 

1

 

 

8

 

 

 

 

 

 

3

 

6

 

9

 

0

 

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A&D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

 

L

 

,

 

+

 

 

9

 

 

 

 

 

 

9

 

9

 

9

 

9

 

 

 

 

 

E

+

 

 

1

 

 

 

9

 

CR

 

LF

 

DP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MT

 

S

 

I

 

+

 

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NU

+

 

9

 

9

 

9

 

 

9

 

 

9

 

 

9

 

9

 

9

 

9

 

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A&D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O

 

L

,

 

-

 

 

 

 

 

9

 

 

9

 

9

9

 

9

 

9

 

 

 

 

9

E

+

 

 

1

 

 

 

 

9

CR

LF

 

DP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MT

 

S

 

I

-

 

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NU

 

 

-

 

9

 

9

 

 

9

 

 

 

9

9

 

 

9

 

9

 

9

 

9

 

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Space,

ASCII

20h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Carriage Return,

ASCII 0Dh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Line Feed,

ASCII

 

 

 

 

0Ah

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

42

Image 44
Contents GH-120 GH-200 GH-300 GH-202 GH-252 1WMPD4000891CPage Contents Underhook Density Measurement Interface And CommunicationIntroduction About This ManualFeatures ComplianceCompliance With FCC Rules Compliance With EMC DirectivesPage Unpacking the Balance Before Use PrecautionsInstalling the Balance During Use ShockPower Supply After UseDisplay Symbols and Key Operation Key When pressed and released When pressed and heldDisplay Key operationWeighing Units Units101 00001 Counting mode Pcs Percent mode Densitymode Press the Print Changing the UnitsExamples Unit Display Gram Balance displaysUnit setting example Precautions for the weighing operation Basic Operation Gram ModeRead . Display symbols and Key operation before operation WeighingDual Range Weighing range Available minimum display01mg 1mgCounting operation Counting Mode PCSStoring a sample unit mass Weighing input mode Counting mode using the Acai function Mark turns off after Unit mass is improved RepeatPercent Mode % Selecting the percent modeStoring the 100% reference mass Reading the percentageAdvise Response AdjustmentAutomatic Response Adjustment Manual Response Adjustment Key untilDisplayed, then release the key Press Key again quicklyCalibration Calibration GroupAutomatic self calibration due to changes in temperature Automatic Self CalibrationOne-Touch Calibration MarkCalibration Test Using the Internal Mass Press and hold the CAL Key until is CCCalibration Using an External Weight Calibration Test Using an External Weight Key................. The key To cancel the operationKey ..............The key to store the new mass value Even if the AC adapter is removed,Correcting the Internal Mass Value Function Switch and Initialization Permit or InhibitKey to display Press the Print key To cancel this operation, pressInitializing the Balance Setting the Function Table Display symbol and keys Function TableSetting procedure Function table is displayed PressKey to select a class Press Key to enter the class Key to select a item PressSetting example Details of the Function Table Factory settings IntData output Time/Date output ID number output5if Timeout AK, Error codeErCd Interface Ct5Description of the Class Environment, Display Description of the Item Data Output Mode Key modeStream mode Auto print modes a and BInterval memory mode Description of the Item Data FormatStandard format DP Dump print formatKF format MT formatNU numerical format Data Unit Terminator Stable value Unstable valueCSV format Data numberDate TimePositive error Negative error SpaceData Format Examples Stable Unstable OverloadUnits Setting the time Clock and Calendar FunctionOperation Confirming the timeSet the date Store Setting the dateQuitting the operation Setting the ID Number ID Number and GLP ReportKey operation Calibration report using the internal massGLP Report Commad Calibration test report using an internal massBalance returns to weighing mode after this test Calibration report using an external weight Calibration test report using an external weight When using preset target value, proceed to stepWeighing data Title block and end blockTitle block Returns to the weighing mode Data MemoryReleasing Clr or err Press and hold the Print key until the keyData Memory for Weighing Data Storing the weighing dataMemory full Interval memorySetting the function table Parameter settings for each output mode are as followsAdditional parameter settings, as follows Enabling the data memory functionDeleting all memory data at one time Recalling the memory dataTransmitting all memory data at one time Data Memory for Calibration and Calibration Test Storing the calibration and calibration test dataTransmitting the memory data Deleting data stored in memoryUnderhook Density Measurement Formula to obtain the densityPrior to measurement Changing the function table Density of a liquidRelation between the water temperature and density Entering the density of a liquidMeasuring the density Output or store Density display Turns off. lightsPress the modes Key to proceed to otherSub 25 pin assignments Standard Input and Output InterfaceRS-232C Interface Connection to Peripheral Equipment Connection to an AD-8121B printerUsing Windows Communication Tools Software WinCT Using the WinCT software, the balance can do the followingConnection to a computer and the use of WinCT RsComCommands Command ListSettings Related to RS-232C Acknowledge Code and Error CodesControl Using CTS and RTS Command Re-zeroing the display Command ExamplesOn command turning on the balance CAL command Calibration with internal mass Error codeCommand ?PT command Net value Tare value Weighing with a tareZero Command ExecutionPT command to set a target weight of 10 g Zero display Treatment of the Balance MaintenanceError Codes Sample mass error Unit mass errorAutomatic response adjustment zero error Automatic response adjustment unstable errorOther Display Asking for Repair Checking the Balance Performance and EnvironmentChecking that the balance performs properly Specifications External Dimensions Unit mmOptions and Peripheral Equipment GH-02 USB interfaceGH-08 Ethernet Interface AD-8121B PrinterAD-1653 Density Determination Kit AD-1683 DC Static EliminatorAX-USB-9P-EX USB Converter 9970 g/cm3AX-SW128 Foot switch AX-T-314A-S External key PlugOther options Terms/Index TermsIndex Options 5pd Out5tart Tare PU5eMemo Memo