A&D GH-120/GH-200/GH-300/GH-202/GH-252 manual Other options

Page 81

Other options

Order code

Name and description

 

Rechargeable Battery

AD-1682

This option allows use of the balance in a place where AC power is

 

not available.

 

Electrostatic field meter

 

This option measures the amount of the static charge on the

AD-1684

sample, tare or peripheral equipment and displays the result.

 

If those are found to be charged, discharge them using the AD-1683

 

DC static eliminator.

 

Anti-vibration table

 

This option can be used when the balance has difficulty stabilizing,

 

due to vibration coming from the floor.

AD-1685

As the table has a high vibration absorbing property, key operations

 

on the balance may make the top of the table tilt slightly, causing a

 

weighing error. To avoid this, use the AD-8922 remote controller to

 

control the balance.

 

Tweezers for calibration weight

AD-1689

This option is the same as the tweezers provided as a standard

accessory and is used when calibrating the balance using an

 

 

external weight.

 

LAN Converter

 

This option can be used to connect the RS-232C interface of the

AD-8526

balance to the Ethernet (LAN) port of a computer. This allows

 

management of the balance weighing data with a computer

 

connected to a network.

 

Remote Display

AD-8920

This option can be connected to the balance using the RS-232C

 

interface.

 

Remote Controller

 

This option can be connected to the balance using the RS-232C

AD-8922

interface and can control the balance remotely.

 

Various options such as comparator output or analog output are

 

available.

79

Image 81
Contents 1WMPD4000891C GH-120 GH-200 GH-300 GH-202 GH-252Page Contents Interface And Communication Underhook Density MeasurementAbout This Manual IntroductionCompliance FeaturesCompliance With FCC Rules Compliance With EMC DirectivesPage Unpacking the Balance Precautions Installing the BalanceBefore Use Shock During UseAfter Use Power SupplyKey When pressed and released When pressed and held Display Symbols and Key OperationDisplay Key operationUnits Weighing Units101 00001 Changing the Units Counting mode Pcs Percent mode Densitymode Press the PrintExamples Unit Display Gram Balance displaysUnit setting example Basic Operation Gram Mode Precautions for the weighing operationRead . Display symbols and Key operation before operation WeighingWeighing range Available minimum display Dual Range01mg 1mgCounting Mode PCS Storing a sample unit mass Weighing input modeCounting operation Mark turns off after Unit mass is improved Repeat Counting mode using the Acai functionSelecting the percent mode Percent Mode %Storing the 100% reference mass Reading the percentageResponse Adjustment Automatic Response AdjustmentAdvise Key until Manual Response AdjustmentDisplayed, then release the key Press Key again quicklyCalibration Group CalibrationAutomatic Self Calibration Automatic self calibration due to changes in temperatureOne-Touch Calibration MarkPress and hold the CAL Key until is CC Calibration Test Using the Internal MassCalibration Using an External Weight Key................. The key To cancel the operation Calibration Test Using an External WeightKey ..............The key to store the new mass value Even if the AC adapter is removed,Correcting the Internal Mass Value Permit or Inhibit Function Switch and InitializationPress the Print key To cancel this operation, press Initializing the BalanceKey to display Function Table Setting the Function Table Display symbol and keysFunction table is displayed Press Setting procedureKey to select a class Press Key to enter the class Key to select a item PressSetting example Details of the Function Table Int Factory settingsData output Time/Date output ID number outputAK, Error code 5if TimeoutErCd Interface Ct5Description of the Class Environment, Display Key mode Description of the Item Data Output ModeStream mode Auto print modes a and BDescription of the Item Data Format Interval memory modeStandard format DP Dump print formatMT format KF formatNU numerical format Data Unit Terminator Stable value Unstable valueData number CSV formatDate TimeNegative error Space Positive errorData Format Examples Stable Unstable OverloadUnits Clock and Calendar Function Setting the timeOperation Confirming the timeSetting the date Quitting the operationSet the date Store ID Number and GLP Report Setting the ID NumberCalibration report using the internal mass GLP ReportKey operation Calibration test report using an internal mass Balance returns to weighing mode after this testCommad Calibration report using an external weight When using preset target value, proceed to step Calibration test report using an external weightTitle block and end block Title blockWeighing data Data Memory Returns to the weighing modeReleasing Clr or err Press and hold the Print key until the keyStoring the weighing data Data Memory for Weighing DataMemory full Interval memoryParameter settings for each output mode are as follows Setting the function tableAdditional parameter settings, as follows Enabling the data memory functionRecalling the memory data Transmitting all memory data at one timeDeleting all memory data at one time Storing the calibration and calibration test data Data Memory for Calibration and Calibration TestTransmitting the memory data Deleting data stored in memoryUnderhook Formula to obtain the density Density MeasurementPrior to measurement Changing the function table Density of a liquidEntering the density of a liquid Relation between the water temperature and densityOutput or store Density display Turns off. lights Measuring the densityPress the modes Key to proceed to otherStandard Input and Output Interface RS-232C InterfaceSub 25 pin assignments Connection to an AD-8121B printer Connection to Peripheral EquipmentUsing the WinCT software, the balance can do the following Using Windows Communication Tools Software WinCTConnection to a computer and the use of WinCT RsComCommand List CommandsAcknowledge Code and Error Codes Control Using CTS and RTSSettings Related to RS-232C Command Examples On command turning on the balanceCommand Re-zeroing the display Error code CAL command Calibration with internal massWeighing with a tare Command ?PT command Net value Tare valueCommand Execution PT command to set a target weight of 10 g Zero displayZero Maintenance Error CodesTreatment of the Balance Unit mass error Sample mass errorAutomatic response adjustment zero error Automatic response adjustment unstable errorOther Display Checking the Balance Performance and Environment Checking that the balance performs properlyAsking for Repair Specifications Unit mm External DimensionsGH-02 USB interface Options and Peripheral EquipmentGH-08 Ethernet Interface AD-8121B PrinterAD-1683 DC Static Eliminator AD-1653 Density Determination KitAX-USB-9P-EX USB Converter 9970 g/cm3AX-T-314A-S External key Plug AX-SW128 Foot switchOther options Terms Terms/IndexIndex 5pd Out Options5tart Tare PU5eMemo Memo