Braun NVL SERIES manual 30787

Page 41

Decals and Antiskid

Decals

32410

LCD Lift Codes

Listed below are codes that the lift controller outputs during lift operation. The codes will be displayed on an LCD screen located on the lift control board inside the pump module.

Non-Flashing Numbers

01 – Platform stowed

02 – Platform unfolding

03 – Platform unfolding paused

04 – Platform at floor level

05 – Platform beginning to lower

06 – Platform lowering (threshold cannot be occupied from this point down)

07 – Outer barrier moving to horizontal position

08 – Platform at ground level

09 – Outer barrier moving to vertical position

10 – Platform raising

11 – Platform raising paused at floor

12 – Platform folding (limited pressure)

13 – Platform folding (full pressure)

14 – Timed fold (cinching lift tite) or (anti-rattle state)

15 – Platform folding stopped

16 – Paused fold

17 – Platform between ground and 3" above ground

18 – Platform above 3"

19 – Outer barrier moving to horizontal postion

20 – The doors are not fully opened (only applicable when door operators are installed)

21 – The doors are opening (only applicable when door operators are installed)

22 – The doors are closing (only applicable when door operators are installed)

28 – Illegal function/not defined

29 – Interlock fault not recognized (or has been cleared but a motion button is still pressed)

30 – Platform location unknown

31 – Platform location transition state; attempting to locate position

35 – Two or more motion buttons are being pressed

36 – The retention belt cannot be buckled while trying to fold or unfold

37 – Motion button being pressed is not a valid motion

50 – Outer barrier is not up above inboard barrier locked position

51 – Threshold is occupied when platform is

1" or more below floor level

52 – Inner rollstop is not up and locked below inner rollstop locked position

53 – Inner rollstop occupied sensor is not activated between floor and inner rollstop up position

54 – Outer barrier is occupied before it is up 55 – Outer barrier is not latched when above the inner rollstop locked position

(Millennium only)

56 – Outer barrier is not up and latched and bridge switch did not deactivate

57 – Outer barrier is not up and latched and ground detect switch did not deactivate (Century and Vista only)

58 – Outer barrier is not up and latched and the platform is 3" above the ground

59 – Outer barrier is not up after pausing platform travel

60 – The kickout gas springs are worn, replace before using

75 – Low voltage detected; must turn off power switch to reset LCD

77 – Vehicle secure interlock has not been activated

90 – Position will be set if you keep holding the button until it beeps

91 – Position is out of a predetermined acceptable range of floor position

92 – Bridge switch is not made, needs adjusting

93 – Inner rollstop occupied switch is not made,

position needs to be moved or switch should be adjusted

94 – Outer barrier is not made, fix and try again 95 – Outer barrier latch is not made (check for jumper on Century and Vista lifts, check

latch on Millennium lifts)

99 – Controller program is not valid; replace controller

Flashing Numbers

Flashing 65 – Unfold button is pressed Flashing 66 – Fold button is pressed Flashing 67 – Down button is pressed Flashing 68 – Up button is pressed Flashing 69 – Bridge switch is activated Flashing 70 – Outer barrier latch switch is

activated

Flashing 71 – Ground detect switch is activated Flashing 72 – Outer barrier up switch is activated Flashing 73 – Inner rollstop up switch is activated Flashing 74 – Inner rollstop occupied switch is

activated

Flashing 76 – Outboard barrier occupied switch is activated

Flashing 78 – Threshold tape switch “A” is activated

Flashing 79 – Threshold tape switch “B” is activated

Flashing 80 – Position set button is pressed Flashing 81 – Single function UP / FOLD /

CLOSE button is pressed Flashing 82 – Single function OPEN / UNFOLD /

DOWN button is pressed Flashing 87 – CLOSE button is pressed Flashing 88 – OPEN button is pressed Flashing 89 – Door full open switch is activated

(or jumper is installed on control board)

31132

WARNING

31132

32201

PLATFORM FOLD RELIEF VALVE ADJUSTMENT

Platform Fold

Relief Valve:

See service manual for adjustment procedure.

30787

CAUTION

Improper handling

and/or servicing

procedures may

result in

electrostatic

discharge (ESD)!

ESD may result in

electronic module

damage.

27154

WARNING

Improper hydraulic pressure switch adjustment may result in serious bodily injury and/or property damage.

HYDRAULIC PRESSURE SWITCH ADJUSTMENT

Adjust switch as specified in installation/service

32410

32201

30787

manual.

27154

Page 39

Image 41
Contents Operators Manual for Congratulations Contents Series No Pump Code Model No Serial No Warranty and Registration InstructionsWarranty and Registration Instructions Illustration Lift TerminologyIntroduction Lift Components Vehicle and Lift Interlocks UP Platform Raise Up is the action of the platform raising Lift Actions and FunctionsDown Platform Lower Safety Symbols Safety FIRST! Know That Lift Operation SafetyLift Operation Safety Precautions RDGDQGXQORDGFOHDURIYHKLFXODUWUDIÀF Lift Operation Safety DXWKRULHG FHUWLÀHG VHUYLFHSHUVRQQHO Operation Notes and Details Press the switch labeled for the intended function Lift Features Disengaged Lift-Tite Latch Engagement Pin Roller When the Unfold switch is When the Fold switch is pressed Fully-Folded Fully-Unfolded Fully-Vertical GLIÀFXOW\XVLQJVWHSV Lift PassengersOperation Notes and Details Operation Notes and Details Wheelchair-Equipped Occupant Seat Belts Operation Procedure ReviewPreventive Maintenance Lift Operating Instructions Open Doors and Secure To Unfold Platform Lift Operating Instructions To Load Passenger To Fold Platform 9HULÀHG Nhtsa Operations ChecklistManual Operating Instructions Release Valve Down To Lower To Unfold Platform OutTo Fold Platform Up To RaiseTo Store Pump Handle To Install Pump Cover Lift is only as safe as Decals and Antiskid30787 22249 Available AntiskidMaintenance and Lubrication DE Door-Ease Lubrication Diagram 750 Cycles Maintenance and Lubrication Schedule750 Perform all procedures listed in previous section also Maintenance and Lubrication Schedule 4500 Cycles Consecutive 750Cycle Intervals Providing Access to the World Public Use Wheelchair Lifts