Fluke ESA612 specifications Standard Terms and Conditions

Page 4

Standard Terms and Conditions

Refunds and Credits

Please note that only serialized products and their accessory items (i.e., products and items bearing a distinct serial number tag) are eligible for partial refund and/or credit. Nonserialized parts and accessory items (e.g., cables, carrying cases, auxiliary modules, etc.) are not eligible for return or refund. Only products returned within 90 days from the date of original purchase are eligible for refund/credit. In order to receive a partial refund/credit of a product purchase price on a serialized product, the product must not have been damaged by the customer or by the carrier chosen by the customer to return the goods, and the product must be returned complete (meaning with all manuals, cables, accessories, etc.) and in “as new” and resalable condition. Products not returned within 90 days of purchase, or products which are not in “as new” and resalable condition, are not eligible for credit return and will be returned to the customer. The Return Procedure (see below) must be followed to assure prompt refund/credit.

Restocking Charges

Products returned within 30 days of original purchase are subject to a minimum restocking fee of 15 %. Products returned in excess of 30 days after purchase, but prior to 90 days, are subject to a minimum restocking fee of 20 %. Additional charges for damage and/or missing parts and accessories will be applied to all returns.

Return Procedure

All items being returned (including all warranty-claim shipments) must be sent freight-prepaid to our factory location. When you return an instrument to Fluke Biomedical, we recommend using United Parcel Service, Federal Express, or Air Parcel Post. We also recommend that you insure your shipment for its actual replacement cost. Fluke Biomedical will not be responsible for lost shipments or instruments that are received in damaged condition due to improper packaging or handling.

Use the original carton and packaging material for shipment. If they are not available, we recommend the following guide for repackaging:

ƒUse a double–walled carton of sufficient strength for the weight being shipped.

ƒUse heavy paper or cardboard to protect all instrument surfaces. Use nonabrasive material around all projecting parts.

ƒUse at least four inches of tightly packed, industry-approved, shock-absorbent material around the instrument.

Image 4
Contents ESA612 Warranty and Product Support Contents Standard Terms and Conditions Certification Restrictions and Liabilities Table of Contents ESA612 Iii ESA612 List of Tables ESA612 List of Figures Viii Electrical Safety Analyzer IntroductionSafety Information Symbol DescriptionElectrical Safety Analyzer Intended UseUnpacking the Analyzer Instrument FamiliarizationInstrument Familiarization Side and Top-Panel Connections Side and Top-Panel Connections Name Connecting to Line Power Turning the Analyzer On Connecting a DUT to the AnalyzerTurning the Analyzer On Accessing the Analyzer’s Functions Leakage Current MenuSetting Polarity Switching Delay Setting Up the AnalyzerSetting the Display Contrast Performing Electrical Safety Tests Setting the Gfci LimitSetting up the Beeper Viewing MemoryPerforming Mains Voltage Testing Setting the Test StandardPerforming a Ground Wire Protective Earth Resistance Test DUT is powered off for this test Electrical Safety Analyzer Fis112.eps Schematic Abbreviations Device Under Test Performing an Insulation Resistance Test Insulation Resistance MeasurementFaw17.eps Applied Parts to Protective-Earth Insulation Test Schematic Mains to Applied Parts Insulation Test Schematic Mains to Non-Earth Accessible Conductive Points Schematic Applied Parts to Non-Earth Conductive Points Schematic Performing a Current Consumption Test Performing Leakage Current TestsMeasuring Earth Leakage Current Electrical Safety Analyzer Earth Leakage Current Test Schematic Performing a Chassis Enclosure Leakage Test Enclosure Leakage Current Test Schematic Performing a Lead-to-Ground Patient Leakage Lead-to-Ground Patient Leakage Current Test Schematic Electrical Safety Analyzer TestsFaw30.eps Electrical Safety Analyzer Lead Isolation Mains On Applied Parts Leakage Test Schematic Performing Electrical Safety Tests Performing an Alternative Equipment LeakageTest Performing an Alternative Applied Part Leakage TestAlternative Equipment Leakage Current Test Schematic Performing a Direct Equipment Leakage Test Alternative Applied Part Leakage Test Schematic When the EN62353 standard is selected Performing a Direct Applied Part Leakage TestDirect Equipment Leakage Test Schematic Direct Applied Parts Leakage Current Test Schematic Performing a Differential Leakage Current Test Differential Leakage Current Test Schematic Using the 1210 Adapter Using the 1210 Adapter ESA612 EGC Lead Connection with 1210 Adapter Measuring Resistance Making Point-To-Point MeasurementsMeasuring Voltage Simulating ECG Waveforms Measuring CurrentESA612 ECG Monitor Connections Using Memory Storing Data into MemoryViewing Memory Data Controlling the Analyzer RemotelyDeleting Data from Memory Maintenance Testing and Replacing the FusesCleaning the Analyzer Cleaning the AnalyzerReplaceable Parts Replaceable Parts Fluke Biomedical Part NumberReplaceable Parts Accessories Specifications TemperatureDetailed Specifications VoltageDetailed Specifications ECG Performance Waveforms