Fluke ESA612 specifications Replaceable Parts Fluke Biomedical Part Number

Page 72

ESA612

Users Manual

Replaceable Parts

Table 6 lists the replaceable parts for the Analyzer.

 

Table 6. Replaceable Parts

 

 

Item

Fluke Biomedical Part Number

 

 

 

ESA612 Getting Started Manual

3334511

 

 

 

ESA612 Users Manual CD

3334509

 

 

 

 

USA

2238680

 

 

 

 

UK

2238596

 

 

 

 

Australia

2238603

 

 

 

Power Cord

Europe

2238615

 

 

France/Belgium

2238615

 

 

 

 

 

Thailand

2238644

 

 

 

 

Israel

2434122

 

 

 

 

Switzerland

3379149

 

 

 

Null Post Adapter

3326842

 

 

Ansur, CD with demo version

2795488

 

 

5-to-5 Banana jack to ECG (BJ2ECG) adapter

3359538

 

 

 

58

Image 72
Contents ESA612 Warranty and Product Support Contents Standard Terms and Conditions Certification Restrictions and Liabilities Table of Contents ESA612 Iii ESA612 List of Tables ESA612 List of Figures Viii Electrical Safety Analyzer IntroductionSafety Information Symbol DescriptionElectrical Safety Analyzer Intended UseUnpacking the Analyzer Instrument FamiliarizationInstrument Familiarization Side and Top-Panel Connections Side and Top-Panel Connections Name Connecting to Line Power Turning the Analyzer On Connecting a DUT to the AnalyzerTurning the Analyzer On Accessing the Analyzer’s Functions Leakage Current MenuSetting Up the Analyzer Setting Polarity Switching DelaySetting the Display Contrast Performing Electrical Safety Tests Setting the Gfci LimitSetting up the Beeper Viewing MemorySetting the Test Standard Performing Mains Voltage TestingPerforming a Ground Wire Protective Earth Resistance Test DUT is powered off for this test Electrical Safety Analyzer Fis112.eps Schematic Abbreviations Device Under Test Performing an Insulation Resistance Test Insulation Resistance MeasurementFaw17.eps Applied Parts to Protective-Earth Insulation Test Schematic Mains to Applied Parts Insulation Test Schematic Mains to Non-Earth Accessible Conductive Points Schematic Applied Parts to Non-Earth Conductive Points Schematic Performing a Current Consumption Test Performing Leakage Current TestsMeasuring Earth Leakage Current Electrical Safety Analyzer Earth Leakage Current Test Schematic Performing a Chassis Enclosure Leakage Test Enclosure Leakage Current Test Schematic Performing a Lead-to-Ground Patient Leakage Lead-to-Ground Patient Leakage Current Test Schematic Electrical Safety Analyzer TestsFaw30.eps Electrical Safety Analyzer Lead Isolation Mains On Applied Parts Leakage Test Schematic Performing Electrical Safety Tests Performing an Alternative Equipment LeakageTest Performing an Alternative Applied Part Leakage TestAlternative Equipment Leakage Current Test Schematic Performing a Direct Equipment Leakage Test Alternative Applied Part Leakage Test Schematic When the EN62353 standard is selected Performing a Direct Applied Part Leakage TestDirect Equipment Leakage Test Schematic Direct Applied Parts Leakage Current Test Schematic Performing a Differential Leakage Current Test Differential Leakage Current Test Schematic Using the 1210 Adapter Using the 1210 Adapter ESA612 EGC Lead Connection with 1210 Adapter Making Point-To-Point Measurements Measuring ResistanceMeasuring Voltage Simulating ECG Waveforms Measuring CurrentESA612 ECG Monitor Connections Using Memory Storing Data into MemoryControlling the Analyzer Remotely Viewing Memory DataDeleting Data from Memory Maintenance Testing and Replacing the FusesCleaning the Analyzer Cleaning the AnalyzerReplaceable Parts Replaceable Parts Fluke Biomedical Part NumberReplaceable Parts Accessories Specifications TemperatureDetailed Specifications VoltageDetailed Specifications ECG Performance Waveforms