Fluke ESA612 specifications Electrical Safety Analyzer

Page 41

Electrical Safety Analyzer

Performing Electrical Safety Tests

IEC60601-1 specifies that the applied parts should be connected for this measurement. Enable this measurement by pressing Eor Fwhich grounds and ungrounds all applied parts connection posts.

27

Image 41 Fluke ESA612 specifications Electrical Safety Analyzer
Contents ESA612 Warranty and Product Support Contents Standard Terms and Conditions Certification Restrictions and Liabilities Table of Contents ESA612 Iii ESA612 List of Tables ESA612 List of Figures Viii Introduction Electrical Safety AnalyzerSymbol Description Safety InformationIntended Use Electrical Safety AnalyzerInstrument Familiarization Unpacking the AnalyzerInstrument Familiarization Side and Top-Panel Connections Side and Top-Panel Connections Name Connecting a DUT to the Analyzer Connecting to Line Power Turning the Analyzer OnTurning the Analyzer On Leakage Current Menu Accessing the Analyzer’s FunctionsSetting the Display Contrast Setting Up the AnalyzerSetting Polarity Switching Delay Setting the Gfci Limit Performing Electrical Safety TestsSetting up the Beeper Viewing MemoryPerforming a Ground Wire Protective Earth Resistance Test Setting the Test StandardPerforming Mains Voltage Testing DUT is powered off for this test Electrical Safety Analyzer Fis112.eps Schematic Abbreviations Device Under Test Insulation Resistance Measurement Performing an Insulation Resistance TestFaw17.eps Applied Parts to Protective-Earth Insulation Test Schematic Mains to Applied Parts Insulation Test Schematic Mains to Non-Earth Accessible Conductive Points Schematic Applied Parts to Non-Earth Conductive Points Schematic Performing Leakage Current Tests Performing a Current Consumption TestMeasuring Earth Leakage Current Electrical Safety Analyzer Earth Leakage Current Test Schematic Performing a Chassis Enclosure Leakage Test Enclosure Leakage Current Test Schematic Performing a Lead-to-Ground Patient Leakage Lead-to-Ground Patient Leakage Current Test Schematic Tests Electrical Safety AnalyzerFaw30.eps Electrical Safety Analyzer Lead Isolation Mains On Applied Parts Leakage Test Schematic Performing an Alternative Equipment Leakage Performing Electrical Safety TestsTest Performing an Alternative Applied Part Leakage TestAlternative Equipment Leakage Current Test Schematic Performing a Direct Equipment Leakage Test Alternative Applied Part Leakage Test Schematic Performing a Direct Applied Part Leakage Test When the EN62353 standard is selectedDirect Equipment Leakage Test Schematic Direct Applied Parts Leakage Current Test Schematic Performing a Differential Leakage Current Test Differential Leakage Current Test Schematic Using the 1210 Adapter Using the 1210 Adapter ESA612 EGC Lead Connection with 1210 Adapter Measuring Voltage Making Point-To-Point MeasurementsMeasuring Resistance Measuring Current Simulating ECG WaveformsESA612 ECG Monitor Connections Storing Data into Memory Using MemoryDeleting Data from Memory Controlling the Analyzer RemotelyViewing Memory Data Testing and Replacing the Fuses MaintenanceCleaning the Analyzer Cleaning the AnalyzerReplaceable Parts Fluke Biomedical Part Number Replaceable PartsReplaceable Parts Accessories Temperature SpecificationsVoltage Detailed SpecificationsDetailed Specifications ECG Performance Waveforms