Fluke ESA612 Making Point-To-Point Measurements, Measuring Resistance, Measuring Voltage

Page 64

ESA612

Users Manual

Making Point-To-Point Measurements

3. Place the probe tips across the unknown voltage and

The Analyzer can make voltage, resistance, and low

read the measurement in the Analyzer’s display.

The Analyzer will measure up to 300 volts ac.

current measurements through its Point-to-Point function.

To access the Point-to-Point function menu shown in

Measuring Resistance

Figure 31, press R. Softkeys F1 through F3 are used

To make a resistance measurement:

to select the measurement function.

1. Press the softkey labeled Resistance from the

 

 

Point-To-Point menu.

 

2. Insert test leads in the RED (V/Ω/A ) and BLACK

 

jacks.

 

3. Null lead resistance by shorting the leads together

 

and pressing the softkey labeled Zero Leads.

 

4. Place the probes across the unknown resistance and

 

read the measurement in the Analyzer’s display.

 

The Analyzer will measure resistances up to 2.0 Ω.

fis108.jpg

 

Figure 31. Point-To-Point Function Menu

 

Measuring Voltage

 

To make a voltage measurement:

 

1. Press the softkey labeled Voltage from the

 

Point-To-Point menu.

 

2. Insert test leads in the RED (V/Ω/A ) and BLACK

 

jacks.

 

50

Image 64
Contents ESA612 Warranty and Product Support Contents Standard Terms and Conditions Certification Restrictions and Liabilities Table of Contents ESA612 Iii ESA612 List of Tables ESA612 List of Figures Viii Electrical Safety Analyzer IntroductionSafety Information Symbol DescriptionElectrical Safety Analyzer Intended UseUnpacking the Analyzer Instrument FamiliarizationInstrument Familiarization Side and Top-Panel Connections Side and Top-Panel Connections Name Connecting to Line Power Turning the Analyzer On Connecting a DUT to the AnalyzerTurning the Analyzer On Accessing the Analyzer’s Functions Leakage Current MenuSetting Polarity Switching Delay Setting Up the AnalyzerSetting the Display Contrast Performing Electrical Safety Tests Setting the Gfci LimitSetting up the Beeper Viewing MemoryPerforming Mains Voltage Testing Setting the Test StandardPerforming a Ground Wire Protective Earth Resistance Test DUT is powered off for this test Electrical Safety Analyzer Fis112.eps Schematic Abbreviations Device Under Test Performing an Insulation Resistance Test Insulation Resistance MeasurementFaw17.eps Applied Parts to Protective-Earth Insulation Test Schematic Mains to Applied Parts Insulation Test Schematic Mains to Non-Earth Accessible Conductive Points Schematic Applied Parts to Non-Earth Conductive Points Schematic Performing a Current Consumption Test Performing Leakage Current TestsMeasuring Earth Leakage Current Electrical Safety Analyzer Earth Leakage Current Test Schematic Performing a Chassis Enclosure Leakage Test Enclosure Leakage Current Test Schematic Performing a Lead-to-Ground Patient Leakage Lead-to-Ground Patient Leakage Current Test Schematic Electrical Safety Analyzer TestsFaw30.eps Electrical Safety Analyzer Lead Isolation Mains On Applied Parts Leakage Test Schematic Performing Electrical Safety Tests Performing an Alternative Equipment LeakageTest Performing an Alternative Applied Part Leakage TestAlternative Equipment Leakage Current Test Schematic Performing a Direct Equipment Leakage Test Alternative Applied Part Leakage Test Schematic When the EN62353 standard is selected Performing a Direct Applied Part Leakage TestDirect Equipment Leakage Test Schematic Direct Applied Parts Leakage Current Test Schematic Performing a Differential Leakage Current Test Differential Leakage Current Test Schematic Using the 1210 Adapter Using the 1210 Adapter ESA612 EGC Lead Connection with 1210 Adapter Measuring Resistance Making Point-To-Point MeasurementsMeasuring Voltage Simulating ECG Waveforms Measuring CurrentESA612 ECG Monitor Connections Using Memory Storing Data into MemoryViewing Memory Data Controlling the Analyzer RemotelyDeleting Data from Memory Maintenance Testing and Replacing the FusesCleaning the Analyzer Cleaning the AnalyzerReplaceable Parts Replaceable Parts Fluke Biomedical Part NumberReplaceable Parts Accessories Specifications TemperatureDetailed Specifications VoltageDetailed Specifications ECG Performance Waveforms