MZ10 F: Bringing the specimen into focus and observing it

Observe the safety directions on page 4 and the recom- mendations on page 5 regarding the use of the mercu- ry-vapour lamp.

Changing filters

In the rapid filter changer, all four positions must be occupied, either with filter sets or with dummy filter carriers (see page 16).. The active filter set is always the one with its inscription on the left..

Turn the sets of filters until the inscription on the one required is visible on the left..

Dioptric correction

We recommend you to carry out the dioptric correction either in transmitted light or in incident light:

If the fluorescence illumi- nator is switched on, use the light stop to block the light (page 16)..

Swing the dummy filter carrier into the beam path (page 16)..

Illuminate a flat test object with transmitted light or with oblique incident light..

Carry out the dioptric correction as directed in the user manual for the stereomicroscope..

Observing fluorescence

Make sure that the UV protection screen is positioned correctly (page 11).

Turn the required filter set into the beam path (page 16)..

Switch on the supply unit (pages 14) and wait for two or three minutes..

Pull out the light stop (page 16)..

Using the lowest magnification, observe the object..

This will give you a better overall view and you will be able to locate features of interest more easily..

Refocus slightly if necessary..

Observe the details at higher magnification..

Reflexes (hot-spots)

When the 1..6planapochromatic objective is used at zoom positions between 0..8 and 1..6, a slight reflex (hot-spot) occurs in the lower part of the field of view; it disappears at higher zoom positions.. This reflex does not arise in conjunction with the 1..0and 0..5planapochromatic objectives or the achromatic objectives..

17

Image 17
Contents Leica Stereo Fluorescence Systems Page Leica stereo-fluorescence module Contents Leica MZ10 F Fluorescence stereomicroscopeDescription Safety conceptLight source Safety regulations Natural science Application Fluorescence filter set ApplicationsIndustry Application Fluorescence filter set 3c 4a OverviewLeica MZ10 F Its components and controls Barrier filter Filter sets for Leica MZ10 FFilter sets Designation Assembly Additional components Video-/phototube Leica MZ10 FDouble-iris diaphragm UV protection screen microscope carrierFitting and changing the mercury-vapour burner AssemblyObserve the safety regulations­ on Stray-light protection Lamp housing assembleRemoving the collector and the heat-protection filter Replacing the collectorFuses Observe the safety regulations onFigs.. a Bringing the discharge arc into focus Adjusting the mercury vapour lampFluoiii filter system Reflexes hot-spots UseDioptric correction 5a, 5b 4a 4b, 4c, 4d Outfit with stereo-fluorescence module ComponentsFilter sets for stereo-fluorescence module 13,14 Fluorescence module stereomicroscope Stereo-fluorescence module Focusing drive base of standVideo-/phototubes Changing the filter setFilterholder fluorescence module Additional assembly instructionsUV-light excluder side-faced column Focusing Transmitted light Stereo-fluorescence module Focusing and observingWith the fluorescence illumination ObservationLeica Microsystems the brand for outstanding products