Uniden BCD436HP, BCD536HP owner manual Favorites List Quick Keys, Wi-Fi Options

Page 42

Access Point Mode is able to connect with up to 5 clients.

Setting parameters are as follows: SSID, Security type, and Password.

Wi-Fi OPTIONS

Make sure the Wi-Fi dongle is connected to the USB port behind the scanner. Press Menu then scroll to Wi-Fi Setup and press E/yes.

Show Wi-Fi Information

Shows the IP address, MAC number, and version when connected.

Shows Wi-Fi not connected’ when the WiFi dongle is not connected.

Set Connection

Off. Not connected.

Infrastructure Mode. Routers etc.

Select AP. Select the access point with the encryption type.

Input Password. Input password to connect.

Access Point Mode. Laptops, Smart devices etc.

Input SSID

Enter (or use default) name of connection. See Data Naming.

Select Security

Open, WPA/WPA2

Input Password. Enter the password for connection.

Reset to Factory

Initialize information for WiFi Setup.

KEY CONCEPTS

Quick Keys

Organizing your Quick Keys will be part of the planning. You will have to figure out which quick keys to assign to your Favorites Lists and Systems so you can scan them without a table of contents and with some sort of logic you can remember. Remember, enabling/disabling quick keys is not the same thing as Avoiding or Unavoiding Systems and Monitor On/Off Favorites Lists.

Favorites List Quick Keys

Favorites Lists Quick Keys are used to enable or disable Favorites Lists for scanning. They are just the number keys on the scanner but once assigned to a Favorites List they become the Quick Keys. Your Favorites Lists hold your Systems that also may have System quick keys assigned to those Systems. You cannot assign a Quick Key in one Favorites List to another Favorites List. Selecting a Favorites List will enable all (Unavoided) Systems in that list for scanning. There

are 100 Quick Keys (0-99) to use for your Favorites Lists. Favorites List Quick Keys can only be assigned once to any one Favorites List, If you don’t assign a Quick Key to a list, it will always be enabled.

34

Image 42
Contents BCD436HP BCD536HP Page Contents Set Your Location and Range Programming Departments Search/Close Call Options Page Fire Tone-Out Modification Notice Important InformationFCC Wants You to Know Part 15 InformationScanning Legally General PrecautionsPower Disconnection Caution Earphone WarningAvis D’INDUSTRIE Canada What You Hear IntroductionHow Does the Home Patrol Work? Create Favorites ListsMain Features Replay TransmissionsRecord Transmissions Page Page Included With Your Scanner BCD436HP BCD536HPConnecting an Optional Antenna Installing Your ScannerPower Related Issues Connecting an Extension SpeakerBase Station Vehicle Installation Mounting Using the BracketMounting Using the DIN-E Sleeve Removing the Scanner from the DIN-E Sleeve Using Internal Batteries BCD436HP Only Mounting Using ISO TechniqueConnecting DC Cable with Orange Wire Using Rechargeable Batteries Understanding the MemoryFavorites Lists Sentinel Software Updating Firmware Manage Firmware UpdatesHow to Install Sentinel Software Updating the DatabaseSetting UP Your Scanner For Model Number ProcedureKeypad and Knob Controls Key OperationBCD436HP Turn to scroll Channel or Frequency in Hold mode Common Controls BCD436HP and BCD536HP No/PRI YesSet Range Set Your Location and RangeSet Location Understanding RangeNew Location or Edit Location Selecting Service TypesEdit Location Set Location Information. See Set Manual LocationData Naming Set Mode SquelchNavigating the Menus Display MenuContrast On or Off Selecting 3-Line Display ModeSet Dimmer BCD436HP Only High, Middle, or Low On or OffView the Battery Level BCD436HP Only SearchingLook at the Display Volume and Squelch IFX Tgid Settings Menu Replay Options Wi-Fi Setup BCD536HP OnlyRestore Options See Scanner InformationWi-Fi Options Quick KeysFavorites List Quick Keys Managing Favorites Lists Review/Edit System At Confirm? Press E/yes or ./noManaging Favorites Lists New System/System SettingsProgramming Systems Understanding Location ControlSystem Settings System Options On or Off Programming Sites New Site/Site OptionsAt Confirm?, press E/yes or ./no Motorola Systems 800/900 Standard or 800 Splinter Edit Name Set ModulationSet Site Type Set Attenuator Band PlanDelete Frequency At Confirm Delete?, press E/yes or ./no Set Base FreqSet Offset Auto, NFM, or FMProgramming Departments New Department/Department OptionsEdit Channel Set Avoid Department OptionsEdit Name Set Location Information Edit ChannelNew Channel/Channel Options Programming Frequencies/TGIDsQuickly Storing a Frequency/TGID Channel OptionsSet Modulation New Channel Edit Name Set Audio Type Set Delay TimeSet Number Tag Set Priority Edit Frequency or Tgid999, Blank No number tag Favorites Quick Key Set Scan SelectionManaging Full Database System Quick KeyTo Use a Startup Key Using Startup KeysPriority Scanning Priority Scan OptionsScanning by Assigning Quick Keys 10 sec100 Scanning Checklist Change Direction or Resume Scan Turn the Scroll ControlSelecting Quick Keys Toggle Display ModesLine Display O Holding Select Service TypesLine Display On Toggle ID Scan or ID Search Replay the Last TransmissionsStore a Search Frequency Search with Scan Start/Stop RecordingAdvanced Channel Menu AttenuationRepeater Frequency Conventional Channel Channel Volume OffsetIntermediate Frequency Exchange Avoiding Channels, Departments, Sites, and SystemsClose Call Modes Using Number TagsDirect Frequency/TGID Entry View Number TagsClose Call Only Priority ModesCustom Search by Search Key Weather ScanQuick Search Using a GPSP25 Adjustment Mode Location-Based ScanningDiscovery Mode New SessionSession Options Set Logging Set DelaySet Time-Out Timer Set Compare to DatabaseReview Discovery Search/Close Call OptionsProgram Band At Confirm? Press E/yes or ./no Rvw Search AvoidSet Each Band 10, -5, 0, 1, 2, 3, 4, 5, 10, or 30 secSearch Options Edit CustomSet Search Key Search with ScanSet System Avoid Custom Search Frequency Intermediate Exchange Weather Alert Priority ModeDirect Frequency Entry Repeater FrequencyClose Call Only Close CallClose Call Options Hits with ScanSet CC Bands Set CC ModeClose Call Only Mode Set CC AlertHolding on a Hit Cancel a HitToggle Close Call Bands View Last HitIntermediate Frequency Exchange Weather OperationWeather Options StoringSet Audio AGC Set Delay TimeSet Attenuator Program SameChange Channel Weather AlertWeather Scan Quick SearchTone-Out Setup Fire Tone-OutReview WX Alerts Set Tone Edit NameSet Frequency Set AlertListen to Tone-Out Frequency Fire Tone-Out Standby/SearchSelect a Different Tone-Out Scroll to Tone-Out Standby and press E/yesScan Mode, Nothing to Scan TroubleshootingAppendix Scanning InterruptedDefault Band Coverage Frequency Range Mode Step Band Lower Upper KHzService Types Service Type DescriptionReformatting the microSD Card Removing the microSD CardEntering IDs System Type Tgid FormatType II Special Status Bits TT ID + # UsageWeather Channels Event Code Watch Advisory Definition?NIC Ctcss Frequencies DCS Codes Reverse ListBase Frequency Offset MHz Repeater Frequency List Technical Specifications BCD436HP VHF High 1 Band Technical Specifications BCD536HP 138..150 MHz 48dB Warranty Information Page