Direct Frequency Entry

Press Channel to hold on any frequency. Enter the frequency and press Channel. Press Channel to release hold.

Frequency Intermediate Exchange

Press Channel to hold on any frequency. Press Func then 7(IFX) to toggle on or off.

Repeater Frequency

Press Channel to hold on any frequency.

Press Func then press and hold 8(REV).

Replay the Last Transmissions

While searching, press Replay.

Press Channel to pause/resume replay.

Turn the Scroll Control to select recordings.

Start/Stop Recording

While searching, press Func then Replay.

Note: Resets to Off when you turn off the scanner.

Storing Frequencies

Displayed Frequency into a Quick Save Department – Press E/yes. You will see Quick Frequency Save in the display then press E/yes.

The scanner stores the frequency into the Quick Save Department in the Quick Save System.

Displayed Frequency into an Existing Department Press E/yes.

You will see Saving to Quick Dept in the display then press ./no.

At Saving Channel to scroll to the Favorites List and press E/yes.

At Select System scroll to the System and press E/yes.

At Select Department scroll to the and press E/yes.

After storing the frequency, you will be at the Edit Channel menu to complete the settings for the new channel.

If you don’t want to edit the channel settings or are done editing the channel, press Avoid to return to searching.

Search Menu

Press Func then Menu.

Close Call Modes

To toggle CC Off, CC Pri, or CC DND: (BCD536HP) Press SQ( ).

(BCD436HP) Press Func then Avoid( ).

Weather Alert Priority Mode

Press Channel to hold on any channel.

Press Func then 6(WX) to toggle on or off.

68

Image 76
Contents BCD436HP BCD536HP Page Contents Set Your Location and Range Programming Departments Search/Close Call Options Page Fire Tone-Out Important Information FCC Wants You to KnowModification Notice Part 15 InformationGeneral Precautions Power Disconnection CautionScanning Legally Earphone WarningAvis D’INDUSTRIE Canada Introduction How Does the Home Patrol Work?What You Hear Create Favorites ListsReplay Transmissions Main FeaturesRecord Transmissions Page Page Included With Your Scanner BCD436HP BCD536HPInstalling Your Scanner Power Related IssuesConnecting an Optional Antenna Connecting an Extension SpeakerBase Station Vehicle Installation Mounting Using the BracketMounting Using the DIN-E Sleeve Removing the Scanner from the DIN-E Sleeve Mounting Using ISO Technique Using Internal Batteries BCD436HP OnlyConnecting DC Cable with Orange Wire Understanding the Memory Using Rechargeable BatteriesFavorites Lists Sentinel Software Manage Firmware Updates How to Install Sentinel SoftwareUpdating Firmware Updating the DatabaseSetting UP Your Scanner For Model Number ProcedureKeypad and Knob Controls Key OperationBCD436HP Turn to scroll Channel or Frequency in Hold mode Common Controls BCD436HP and BCD536HP No/PRI YesSet Your Location and Range Set LocationSet Range Understanding RangeSelecting Service Types Edit LocationNew Location or Edit Location Set Location Information. See Set Manual LocationSet Mode Squelch Navigating the MenusData Naming Display MenuOn or Off Selecting 3-Line Display Mode Set Dimmer BCD436HP Only High, Middle, or LowContrast On or OffSearching View the Battery Level BCD436HP OnlyLook at the Display Volume and Squelch IFX Tgid Settings Menu Wi-Fi Setup BCD536HP Only Restore OptionsReplay Options See Scanner InformationQuick Keys Wi-Fi OptionsFavorites List Quick Keys Managing Favorites Lists Review/Edit System At Confirm? Press E/yes or ./noNew System/System Settings Programming SystemsManaging Favorites Lists Understanding Location ControlSystem Settings System Options On or Off New Site/Site Options Programming SitesAt Confirm?, press E/yes or ./no Edit Name Set Modulation Set Site Type Set AttenuatorMotorola Systems 800/900 Standard or 800 Splinter Band PlanSet Base Freq Set OffsetDelete Frequency At Confirm Delete?, press E/yes or ./no Auto, NFM, or FMProgramming Departments New Department/Department OptionsDepartment Options Edit Name Set Location InformationEdit Channel Set Avoid Edit ChannelProgramming Frequencies/TGIDs Quickly Storing a Frequency/TGIDNew Channel/Channel Options Channel OptionsSet Audio Type Set Delay Time Set Number Tag Set PrioritySet Modulation New Channel Edit Name Edit Frequency or Tgid999, Blank No number tag Set Scan Selection Managing Full DatabaseFavorites Quick Key System Quick KeyUsing Startup Keys Priority ScanningTo Use a Startup Key Priority Scan Options10 sec Scanning by Assigning Quick Keys100 Scanning Checklist Change Direction or Resume Scan Turn the Scroll ControlToggle Display Modes Selecting Quick KeysLine Display O Select Service Types Line Display On Toggle ID Scan or ID SearchHolding Replay the Last TransmissionsStart/Stop Recording Advanced Channel MenuStore a Search Frequency Search with Scan AttenuationChannel Volume Offset Intermediate Frequency ExchangeRepeater Frequency Conventional Channel Avoiding Channels, Departments, Sites, and SystemsUsing Number Tags Direct Frequency/TGID EntryClose Call Modes View Number TagsPriority Modes Custom Search by Search KeyClose Call Only Weather ScanUsing a GPS P25 Adjustment ModeQuick Search Location-Based ScanningDiscovery Mode New SessionSession Options Set Delay Set Time-Out TimerSet Logging Set Compare to DatabaseReview Discovery Search/Close Call OptionsAt Confirm? Press E/yes or ./no Rvw Search Avoid Set Each BandProgram Band 10, -5, 0, 1, 2, 3, 4, 5, 10, or 30 secSearch Options Edit CustomSearch with Scan Set Search KeySet System Avoid Custom Search Weather Alert Priority Mode Direct Frequency EntryFrequency Intermediate Exchange Repeater FrequencyClose Call Close Call OptionsClose Call Only Hits with ScanSet CC Mode Close Call Only ModeSet CC Bands Set CC AlertCancel a Hit Toggle Close Call BandsHolding on a Hit View Last HitWeather Operation Weather OptionsIntermediate Frequency Exchange StoringSet Delay Time Set AttenuatorSet Audio AGC Program SameWeather Alert Weather ScanChange Channel Quick SearchFire Tone-Out Tone-Out SetupReview WX Alerts Edit Name Set FrequencySet Tone Set AlertFire Tone-Out Standby/Search Select a Different Tone-OutListen to Tone-Out Frequency Scroll to Tone-Out Standby and press E/yesTroubleshooting AppendixScan Mode, Nothing to Scan Scanning InterruptedDefault Band Coverage Frequency Range Mode Step Band Lower Upper KHzService Types Service Type DescriptionRemoving the microSD Card Entering IDsReformatting the microSD Card System Type Tgid FormatType II Special Status Bits TT ID + # UsageWeather Channels Event Code Watch Advisory Definition?NIC Ctcss Frequencies Reverse List DCS CodesBase Frequency Offset MHz Repeater Frequency List Technical Specifications BCD436HP VHF High 1 Band Technical Specifications BCD536HP 138..150 MHz 48dB Warranty Information Page