Uniden BCD436HP, BCD536HP owner manual On or Off

Page 48

Edit Fleet Map (Motorola Type I/lli systems Only) – This allows you to program a fleet map for Motorola Type I Systems. You must program a system fleet map in order for the scanner to properly track and display talk group IDs.

Block 0 Scroll to the size code (0-14) and press E/yes.

The next available block is prompted to select the next size code (0-14).

Repeat for each block as needed (0-7).

Note: If you select size code 12, 13, or 14, these restrictions apply:

12 can only be assigned to Blocks 0, 2, 4 or 6. 13 can only be assigned to Blocks 0 and 4.

14 can only be assigned to Block 0.

Since these size codes require multiple blocks, you will be prompted for the next available block. Example: If you assign Block 0 as 12, the scanner prompts you for block 2, the next block available, instead of block 1.

Priority ID Scan (no P25 One Freq) – This allows you to use Priority Scan with IDs in the System. The default setting is Off.

On or Off

Set Status Bit (Motorola Only) – This sets how your scanner works with Status Bits (also called S-bits), letting you control how the scanner interprets and displays Motorola talk group IDs. The default setting is Ignore.

Yes. The scanner treats all received IDs as unique IDs.

Ignore. The scanner rounds all received IDs down to the next interval of 16.

Set End Code (Motorola Only) – This sets how the scanner handles the transmission end code sent by most Motorola Systems.

The default setting is Analog.

Analog. The scanner recognizes only analog end transmission codes. Analog+Digital. The scanner recognizes both analog and digital end codes. Ignore. The scanner waits for the carrier to drop before leaving a channel.

Emergency Alert (Motorola/EDACS Only) – This sets how your scanner alerts you to IDs that have the emergency flag set. The default setting is Off.

Set Alert Tone

Alert 1-9 or Off.

Set Level

Level 1-15 or Auto (the master volume level).

Set Alert Light

Set Color

Off, Blue, Red, Magenta, Green, Cyan, Yellow, or White.

Set Pattern

On, Slow Blink, or Fast Blink.

Review ID Avoids – This allows you to review Avoided IDs in the System. Temporary Avoids

appear reversed in the display: .

Stop Avoiding?. Scroll to ID and press E/yes to Stop Avoiding. Nothing Avoided appears if nothing is Avoided.

Clear All ID Avoids – This allows you to Stop Avoiding all Avoided IDs in the System.

40

Image 48
Contents BCD436HP BCD536HP Page Contents Set Your Location and Range Programming Departments Search/Close Call Options Page Fire Tone-Out Important Information FCC Wants You to KnowModification Notice Part 15 InformationGeneral Precautions Power Disconnection CautionScanning Legally Earphone WarningAvis D’INDUSTRIE Canada Introduction How Does the Home Patrol Work?What You Hear Create Favorites ListsMain Features Replay TransmissionsRecord Transmissions Page Page Included With Your Scanner BCD436HP BCD536HPInstalling Your Scanner Power Related IssuesConnecting an Optional Antenna Connecting an Extension SpeakerBase Station Vehicle Installation Mounting Using the BracketMounting Using the DIN-E Sleeve Removing the Scanner from the DIN-E Sleeve Using Internal Batteries BCD436HP Only Mounting Using ISO TechniqueConnecting DC Cable with Orange Wire Using Rechargeable Batteries Understanding the MemoryFavorites Lists Sentinel Software Manage Firmware Updates How to Install Sentinel SoftwareUpdating Firmware Updating the DatabaseSetting UP Your Scanner For Model Number ProcedureKeypad and Knob Controls Key OperationBCD436HP Turn to scroll Channel or Frequency in Hold mode Common Controls BCD436HP and BCD536HP No/PRI YesSet Your Location and Range Set LocationSet Range Understanding RangeSelecting Service Types Edit LocationNew Location or Edit Location Set Location Information. See Set Manual LocationSet Mode Squelch Navigating the MenusData Naming Display MenuOn or Off Selecting 3-Line Display Mode Set Dimmer BCD436HP Only High, Middle, or LowContrast On or OffView the Battery Level BCD436HP Only SearchingLook at the Display Volume and Squelch IFX Tgid Settings Menu Wi-Fi Setup BCD536HP Only Restore OptionsReplay Options See Scanner InformationWi-Fi Options Quick KeysFavorites List Quick Keys Managing Favorites Lists Review/Edit System At Confirm? Press E/yes or ./noNew System/System Settings Programming SystemsManaging Favorites Lists Understanding Location ControlSystem Settings System Options On or Off Programming Sites New Site/Site OptionsAt Confirm?, press E/yes or ./no Edit Name Set Modulation Set Site Type Set AttenuatorMotorola Systems 800/900 Standard or 800 Splinter Band PlanSet Base Freq Set OffsetDelete Frequency At Confirm Delete?, press E/yes or ./no Auto, NFM, or FMProgramming Departments New Department/Department OptionsDepartment Options Edit Name Set Location InformationEdit Channel Set Avoid Edit ChannelProgramming Frequencies/TGIDs Quickly Storing a Frequency/TGIDNew Channel/Channel Options Channel OptionsSet Audio Type Set Delay Time Set Number Tag Set PrioritySet Modulation New Channel Edit Name Edit Frequency or Tgid999, Blank No number tag Set Scan Selection Managing Full DatabaseFavorites Quick Key System Quick KeyUsing Startup Keys Priority ScanningTo Use a Startup Key Priority Scan OptionsScanning by Assigning Quick Keys 10 sec100 Scanning Checklist Change Direction or Resume Scan Turn the Scroll ControlSelecting Quick Keys Toggle Display ModesLine Display O Select Service Types Line Display On Toggle ID Scan or ID SearchHolding Replay the Last TransmissionsStart/Stop Recording Advanced Channel MenuStore a Search Frequency Search with Scan AttenuationChannel Volume Offset Intermediate Frequency ExchangeRepeater Frequency Conventional Channel Avoiding Channels, Departments, Sites, and SystemsUsing Number Tags Direct Frequency/TGID EntryClose Call Modes View Number TagsPriority Modes Custom Search by Search KeyClose Call Only Weather ScanUsing a GPS P25 Adjustment ModeQuick Search Location-Based ScanningDiscovery Mode New SessionSession Options Set Delay Set Time-Out TimerSet Logging Set Compare to DatabaseReview Discovery Search/Close Call OptionsAt Confirm? Press E/yes or ./no Rvw Search Avoid Set Each BandProgram Band 10, -5, 0, 1, 2, 3, 4, 5, 10, or 30 secSearch Options Edit CustomSet Search Key Search with ScanSet System Avoid Custom Search Weather Alert Priority Mode Direct Frequency EntryFrequency Intermediate Exchange Repeater FrequencyClose Call Close Call OptionsClose Call Only Hits with ScanSet CC Mode Close Call Only ModeSet CC Bands Set CC AlertCancel a Hit Toggle Close Call BandsHolding on a Hit View Last HitWeather Operation Weather OptionsIntermediate Frequency Exchange StoringSet Delay Time Set AttenuatorSet Audio AGC Program SameWeather Alert Weather ScanChange Channel Quick SearchTone-Out Setup Fire Tone-OutReview WX Alerts Edit Name Set FrequencySet Tone Set AlertFire Tone-Out Standby/Search Select a Different Tone-OutListen to Tone-Out Frequency Scroll to Tone-Out Standby and press E/yesTroubleshooting AppendixScan Mode, Nothing to Scan Scanning InterruptedDefault Band Coverage Frequency Range Mode Step Band Lower Upper KHzService Types Service Type DescriptionRemoving the microSD Card Entering IDsReformatting the microSD Card System Type Tgid FormatType II Special Status Bits TT ID + # UsageWeather Channels Event Code Watch Advisory Definition?NIC Ctcss Frequencies DCS Codes Reverse ListBase Frequency Offset MHz Repeater Frequency List Technical Specifications BCD436HP VHF High 1 Band Technical Specifications BCD536HP 138..150 MHz 48dB Warranty Information Page