Uniden BCD436HP, BCD536HP owner manual 999, Blank No number tag, On or Off

Page 56

Set Number Tag – This allows you to number a Channel so you can access it quickly from scan hold mode.

The default setting is no number tag. See also Using Number Tags.

0-999, Blank (No number tag)

Set Modulation (Conventional Only) – This setting selects the modulation used for the channel. The default setting is Auto.

Auto, AM, FM, NFM, WFM, or FMB (FM Broadcast) See also Scan Modulation.

Set Attenuator (Conventional Only) – This setting controls whether the scanner attenuates signals on the Channel by about 20 dB.

The default setting is Off.

On or Off

See also Scan Attenuation.

Set Service Type – This sets the Service Type for The Channel.

The Appendix has a list of Service Types and their general descriptions. Default is Custom 1.

Scroll to the Service Type and press E/yes.

Set Delay Time – This sets (in seconds) the amount of time the scanner stays on a channel after the transmission has ended before moving to the next channel. A negative delay will force a resume after that number of seconds.

The default setting is 2 seconds.

-10, -5, 0, 1, 2, 3, 4, 5, 10, or 30 sec.

Set Priority – This sets the channel as a priority channel while scanning. The default setting is Off.

Note: To use Priority ID Scan you must also enable Priority ID Scan for each System. See also Priority Scanning.

On or Off

Set Alert – This setting controls when and how the scanner alerts you if the channel becomes active. The default setting is Off.

Set Alert Tone

Alert 1-9 or Off.

Set Level

Level 1-15 or Auto (the master volume level).

Set Alert Light

Set Color

Off, Blue, Red, Magenta, Green, Cyan, Yellow, or White.

Set Pattern

On, Slow Blink, or Fast Blink.

Set Avoid – This determines whether a channel will be scanned or not. Temporary Avoids cancel you cycle power. The default setting is Stop Avoiding.

Stop Avoiding, Temporary Avoid, or Permanent Avoid

See also Scan Avoids.

Volume Offset – This sets the Volume Offset for the Channel.

48

Image 56
Contents BCD436HP BCD536HP Page Contents Set Your Location and Range Programming Departments Search/Close Call Options Page Fire Tone-Out Important Information FCC Wants You to KnowModification Notice Part 15 InformationGeneral Precautions Power Disconnection CautionScanning Legally Earphone WarningAvis D’INDUSTRIE Canada Introduction How Does the Home Patrol Work?What You Hear Create Favorites ListsRecord Transmissions Main FeaturesReplay Transmissions Page Page Included With Your Scanner BCD436HP BCD536HPInstalling Your Scanner Power Related IssuesConnecting an Optional Antenna Connecting an Extension SpeakerBase Station Vehicle Installation Mounting Using the BracketMounting Using the DIN-E Sleeve Removing the Scanner from the DIN-E Sleeve Connecting DC Cable with Orange Wire Using Internal Batteries BCD436HP OnlyMounting Using ISO Technique Favorites Lists Using Rechargeable BatteriesUnderstanding the Memory Sentinel Software Manage Firmware Updates How to Install Sentinel SoftwareUpdating Firmware Updating the DatabaseSetting UP Your Scanner For Model Number ProcedureKeypad and Knob Controls Key OperationBCD436HP Turn to scroll Channel or Frequency in Hold mode Common Controls BCD436HP and BCD536HP No/PRI YesSet Your Location and Range Set LocationSet Range Understanding RangeSelecting Service Types Edit LocationNew Location or Edit Location Set Location Information. See Set Manual LocationSet Mode Squelch Navigating the MenusData Naming Display MenuOn or Off Selecting 3-Line Display Mode Set Dimmer BCD436HP Only High, Middle, or LowContrast On or OffLook at the Display View the Battery Level BCD436HP OnlySearching Volume and Squelch IFX Tgid Settings Menu Wi-Fi Setup BCD536HP Only Restore OptionsReplay Options See Scanner InformationFavorites List Quick Keys Wi-Fi OptionsQuick Keys Managing Favorites Lists Review/Edit System At Confirm? Press E/yes or ./noNew System/System Settings Programming SystemsManaging Favorites Lists Understanding Location ControlSystem Settings System Options On or Off At Confirm?, press E/yes or ./no Programming SitesNew Site/Site Options Edit Name Set Modulation Set Site Type Set AttenuatorMotorola Systems 800/900 Standard or 800 Splinter Band PlanSet Base Freq Set OffsetDelete Frequency At Confirm Delete?, press E/yes or ./no Auto, NFM, or FMProgramming Departments New Department/Department OptionsDepartment Options Edit Name Set Location InformationEdit Channel Set Avoid Edit ChannelProgramming Frequencies/TGIDs Quickly Storing a Frequency/TGIDNew Channel/Channel Options Channel OptionsSet Audio Type Set Delay Time Set Number Tag Set PrioritySet Modulation New Channel Edit Name Edit Frequency or Tgid999, Blank No number tag Set Scan Selection Managing Full DatabaseFavorites Quick Key System Quick KeyUsing Startup Keys Priority ScanningTo Use a Startup Key Priority Scan Options100 Scanning by Assigning Quick Keys10 sec Scanning Checklist Change Direction or Resume Scan Turn the Scroll ControlLine Display O Selecting Quick KeysToggle Display Modes Select Service Types Line Display On Toggle ID Scan or ID SearchHolding Replay the Last TransmissionsStart/Stop Recording Advanced Channel MenuStore a Search Frequency Search with Scan AttenuationChannel Volume Offset Intermediate Frequency ExchangeRepeater Frequency Conventional Channel Avoiding Channels, Departments, Sites, and SystemsUsing Number Tags Direct Frequency/TGID EntryClose Call Modes View Number TagsPriority Modes Custom Search by Search KeyClose Call Only Weather ScanUsing a GPS P25 Adjustment ModeQuick Search Location-Based ScanningDiscovery Mode New SessionSession Options Set Delay Set Time-Out TimerSet Logging Set Compare to DatabaseReview Discovery Search/Close Call OptionsAt Confirm? Press E/yes or ./no Rvw Search Avoid Set Each BandProgram Band 10, -5, 0, 1, 2, 3, 4, 5, 10, or 30 secSearch Options Edit CustomSet System Avoid Set Search KeySearch with Scan Custom Search Weather Alert Priority Mode Direct Frequency EntryFrequency Intermediate Exchange Repeater FrequencyClose Call Close Call OptionsClose Call Only Hits with ScanSet CC Mode Close Call Only ModeSet CC Bands Set CC AlertCancel a Hit Toggle Close Call BandsHolding on a Hit View Last HitWeather Operation Weather OptionsIntermediate Frequency Exchange StoringSet Delay Time Set AttenuatorSet Audio AGC Program SameWeather Alert Weather ScanChange Channel Quick SearchReview WX Alerts Tone-Out SetupFire Tone-Out Edit Name Set FrequencySet Tone Set AlertFire Tone-Out Standby/Search Select a Different Tone-OutListen to Tone-Out Frequency Scroll to Tone-Out Standby and press E/yesTroubleshooting AppendixScan Mode, Nothing to Scan Scanning InterruptedDefault Band Coverage Frequency Range Mode Step Band Lower Upper KHzService Types Service Type DescriptionRemoving the microSD Card Entering IDsReformatting the microSD Card System Type Tgid FormatType II Special Status Bits TT ID + # UsageWeather Channels Event Code Watch Advisory Definition?NIC Ctcss Frequencies Base Frequency Offset MHz DCS CodesReverse List Repeater Frequency List Technical Specifications BCD436HP VHF High 1 Band Technical Specifications BCD536HP 138..150 MHz 48dB Warranty Information Page