Heat Controller A-MMH36FA-1 manual Product Specifications, Indoor Unit Type Wall Mounted Model

Page 15

Product Specifications

Product Specifications

Indoor Unit

Indoor Unit Type

 

 

Wall Mounted

 

 

Model

 

B-MMC09FA-1

B-MMH09FA-1

B-MMC12FA-1

B-MMH12FA-1

 

 

 

 

 

 

Nominal Cooling Capacity

kcal/h(W)

2,267(2,637)

2,267(2,637)

3,023(3,516)

3,023(3,516)

 

 

 

 

 

 

 

 

 

Btu/h

9,000

9,000

12,000

12,000

 

 

 

 

 

 

 

Nominal Heating Capacity

kcal/h(W)

-

2,267(2,637)

-

3,023(3,516)

 

 

 

 

 

 

 

 

 

Btu/h

-

9,000

-

12,000

 

 

 

 

 

 

 

Air Circulation

 

CFM(CMM)

289(8.2)

289(8.2)

332(9.4)

332(9.4)

 

 

 

 

 

 

 

Setting temperature range(cool/heat)

°C

18~30

18~30

18~30

18~30

 

 

 

 

 

 

 

Fan motor

Output

W

15

15

15

15

 

 

 

 

 

 

 

 

Model

 

DL-88430LGIF

DL-88430LGIF

DL-88430LGIF

DL-88430LGIF

 

 

 

 

 

 

 

 

Input

V

DC36

DC36

DC36

DC36

 

 

 

 

 

 

 

 

Running Current

A

0.15

0.15

0.15

0.15

 

 

 

 

 

 

 

Fan

Type

 

Cross Flow Fan

Cross Flow Fan

Cross Flow Fan

Cross Flow Fan

 

 

 

 

 

 

 

 

No. Used / Diameter

EA/inch(mm)

1/3.74(95)

1/3.74(95)

1/3.74(95)

1/3.74(95)

 

 

 

 

 

 

 

Noise Level (Sound Press,1m) H/M/L

dBA

31 / 29 / 22

31 / 29 / 22

36 / 32 / 29

36 / 32 / 29

 

 

 

 

 

 

 

Temperature controller

 

Thermistor

Thermistor

Thermistor

Thermistor

 

 

 

 

 

 

 

Coil

Tube Size (OD)

inch(mm)

0.197(5.0)

0.197(5.0)

0.197(5.0)

0.197(5.0)

 

 

 

 

 

 

 

 

Fins per inch

 

20

20

18

18

 

 

 

 

 

 

 

 

No. of Rows & Column

 

2R,15C

2R,15C

2R,15C

2R,15C

 

 

 

 

 

 

 

Dehumidification Rate

pints/day

-

12.4

-

13.5

 

 

 

 

 

 

 

Dimensions (W*H*D)

inch(mm)

33.0*10.6*6.0(840*270*153)

33.0*10.6*6.0(840*270*153)

35.2*11.1*6.5(895*282*165)

35.2*11.1*6.5(895*282*165)

 

 

 

 

 

 

 

Net Weight

 

lbs(kg)

15.4(7)

15.4(7)

20.9(9.5)

20.9(9.5)

 

 

 

 

 

 

 

Piping Connection

Liquid

inch(mm)

1/4 (6.35)

1/4 (6.35)

1/4 (6.35)

1/4 (6.35)

 

 

 

 

 

 

 

 

Gas

inch(mm)

3/8 (9.52)

3/8 (9.52)

3/8 (9.52)

3/8 (9.52)

 

 

 

 

 

 

 

 

Drain hose (ID Ø)

inch(mm)

0.79(20)

0.79(20)

0.79(20)

0.79(20)

 

 

 

 

 

 

 

Packing Dimension (W*H*D)

inch(mm)

35.7*13.1*8.8(906*332*223)

35.7*13.1*8.8(906*332*223)

38.3*9.1*14.6(973*231*372)

38.3*9.1*14.6(973*231*372)

 

 

 

 

 

 

 

Stuffing Quantity

With(Without) S/Parts

20/40ft(hi-c)

440/910 (1091)

440/910 (1091)

353/719 (792)

353/719 (792)

 

 

 

 

 

 

 

Note : 1. Due to our policy of innovation some specifications may be changed without notification.

- 15 -

Service Manual

Image 15
Contents Heat CONTROLLER, INC Table of Contents Symbols Used in this Manual KBtu/h 2 roomsKBtu/h 3 rooms Control box securely Cuit and breaker Safety PrecautionsInstallation Be sure not to do Be sure to follow the instructionDo not allow water to run into electric parts Do not install, remove, or reDo not install the product on a Defective installation standWhen the product is soaked Be cautious that water can Never enter the productFlooded or submerged, contact Install the drain hose to ensure that Keep level even when Installing the productUse two or more people to lift and transport the product Operational Do not use the remote is the batteries have leaked Selecting the locationOutdoor Unit Seaside applications and installationDimensions Indoor UnitSplit Type Indoor 18kBtu/h Outdoor Unit24kBtu/h 36kBtu/h UE2Indoor Unit Type Wall Mounted Model Product SpecificationsMMC18FA-1 MMH18FA-1 Outdoor Unit Multiple piping modelsMMC24FA-1 MMH24FA-1 MMC36FA-1 MMH36FA-1 Installation Installation PartsInstallation Tools Selecting the best location Piping length and elevation Multi Piping Type18 / 24 kBtu/h KBtu/h Drilling the hole in the wall Installing Installation PlateStandard TypeFlaring work Flaring Work and Connection of PipingConnecting the Piping CheckIndoor Wrap the insulation material around the all connections Indoor unit installationFor left rear piping Wrap the insulation material around the connecting por- tion Bad case Good caseRemote Control Preparationoptional Outdoor Outdoor unit 18/24 kBtu/hOutdoor unit 36 kBtu/h Tions ETL recognized and CSA certified Connect the cable to the Indoor unitOutdoor unit Connect the cable to the Outdoor unitHow to connect wiring to the terminals Methods of connecting the cableModel Checking the drainage To check the drainageDrain piping Insulating the Pipe and Special Piping Applications Secure the taped piping along the exterior wall usingLeakage test Air Purging and EvacuationLeak checking PreparationRepeat evacuation procedure for each indoor unit EvacuationFinishing the job Additional ChargingSplit Type Test RunningOperation Cooling Mode OperationSoft Dry Operation Mode Heating Mode OperationDefrost ControlHeating Fuzzy OperationFuzzy Operation for Cooling Fuzzy Operation for Dehumidification On-Timer OperationOff-Timer Operation Airflow Speed SelectionChaos Natural Wind Mode Off-Timer = On-Timer OperationSleep Timer Operation Chaos Swing ModeBuzzer Sound Forced OperationSplit Type Indoor Unit Function of Indoor UnitFunction of Outdoor Unit Remote Control Operation Time Setting Buttons Used to adjust the timeCooling Model , Heat Pump Model To remove the Grille from the Chassis DisassemblyTo remove the Control Box To remove the Motor Cover Schematic Diagram Electronic Control DeviceIndoor Unit TMP87CM41F Outdoor UnitRY-4WAY RY-LIQ RY-GAS RY-FANL RY-FANH Indoor Unit Outdoor Unit Wiring DiagramMMC24FA-1 Bottom View Component LocationsDisplay Assembly Split Type 6871A20680 Component side Solder side MMH18FA-1 Troubleshooting GuideRefrigeration Cycle Diagram MMC18FA-1MMH24FA-1 MMH36FA-1 MMC36FA-1Self-diagnosis Function Indoor ErrorOutdoor Error Error IndicatorTrouble analysis Cycle Troubleshooting GuideProcedure Specification Remedy Electronic Parts Troubleshooting GuideProduct doesnt operate with the remote controller Check Point Comp. on Comp. OFF Compressor/Outdoor Fan dont operateNector Trouble 4 When indoor Fan does not operateRY-COMP-B Voltage of Connectors according to Indoor Fan SpeedWhen Vertical Louver does not operate Indoor inlet pipe sensor Error CodeCheck Point Indoor air sensorDescription Cause of error Check point & Normal condition Power input AC 230V.Outdoor, IndoorCommunication line is shorted at GND Comp OFF Outdoor air sensor Condensor pipe sensorPipe sensor Way Valve Liguid Side Way, 3-way ValvePumping down ProcedureReplace the valve and service port caps EvacuationAll the refrigerant leaked Connect the gauge to the charging cylinder Replace the valve stem nuts and the service port nutGas Charging After EvacuationModel B-MMC09FA-1, B-MMH09FA-1, B-MMC12FA-1, B-MMH12FA-1 Exploded ViewModel A-MMC18FA-1, A-MMH18FA-1 Model A-MMC24FA-1, A-MMH24FA-1 Model A-MMC36FA-1, A-MMH36FA-1 08/06/2008 Heat CONTROLLER, INC