Heat Controller A-MMC36FA-1, B-MMH12FA-1, B-MMC12FA-1 manual Remote Control Preparationoptional

Page 29

Flaring Work and Connection of Piping

REMOTE CONTROL PREPARATION(OPTIONAL)

HOW TO MOUNT ONTO A WALL

HOW TO INSERT BATTERIES

Remove the battery cover from the remote con- troller.

• Slide the cover according to the arrow direction.

Insert the two batteries.(AAA, 1.5V)

Be sure that the (+) and (-) directions are correct.

Be sure that both batteries are new.

Re-attach the cover.

• Slide it back into position.

Do not use rechargeable batteries, such batteries differ from standard dry cells in shape, dimensions, and per- formance.

Romove the batteries from the remote controller if the air conditioner is not going to be used for a long length of time.

- 29 -

Service Manual

Image 29
Contents Heat CONTROLLER, INC Table of Contents KBtu/h 3 rooms Symbols Used in this ManualKBtu/h 2 rooms Installation Safety PrecautionsBe sure not to do Be sure to follow the instruction Control box securely Cuit and breakerDo not install the product on a Do not install, remove, or reDefective installation stand Do not allow water to run into electric partsFlooded or submerged, contact When the product is soaked Be cautious that water canNever enter the product Use two or more people to lift and transport the product Install the drain hose to ensure that Keep level even whenInstalling the product Operational Do not use the remote is the batteries have leaked Selecting the locationOutdoor Unit Seaside applications and installationSplit Type Indoor DimensionsIndoor Unit 18kBtu/h Outdoor Unit24kBtu/h 36kBtu/h UE2Indoor Unit Type Wall Mounted Model Product SpecificationsMMC18FA-1 MMH18FA-1 Outdoor Unit Multiple piping modelsMMC24FA-1 MMH24FA-1 MMC36FA-1 MMH36FA-1 Installation Tools InstallationInstallation Parts Selecting the best location 18 / 24 kBtu/h KBtu/h Piping length and elevationMulti Piping Type Drilling the hole in the wall Installing Installation PlateStandard TypeFlaring work Flaring Work and Connection of PipingIndoor Connecting the PipingCheck Wrap the insulation material around the all connections Indoor unit installationFor left rear piping Wrap the insulation material around the connecting por- tion Bad case Good caseRemote Control Preparationoptional Outdoor unit 36 kBtu/h OutdoorOutdoor unit 18/24 kBtu/h Tions ETL recognized and CSA certified Connect the cable to the Indoor unitOutdoor unit Connect the cable to the Outdoor unitHow to connect wiring to the terminals Methods of connecting the cableModel Drain piping Checking the drainageTo check the drainage Insulating the Pipe and Special Piping Applications Secure the taped piping along the exterior wall usingLeak checking Air Purging and EvacuationPreparation Leakage testFinishing the job Repeat evacuation procedure for each indoor unitEvacuation Additional ChargingSplit Type Test RunningSoft Dry Operation Mode Cooling Mode OperationHeating Mode Operation OperationFuzzy Operation for Cooling Defrost ControlHeatingFuzzy Operation Off-Timer Operation On-Timer OperationAirflow Speed Selection Fuzzy Operation for DehumidificationSleep Timer Operation Off-Timer = On-Timer OperationChaos Swing Mode Chaos Natural Wind ModeBuzzer Sound Forced OperationSplit Type Indoor Unit Function of Indoor UnitFunction of Outdoor Unit Cooling Model , Heat Pump Model Remote Control OperationTime Setting Buttons Used to adjust the time To remove the Grille from the Chassis DisassemblyTo remove the Control Box To remove the Motor Cover Indoor Unit Schematic DiagramElectronic Control Device TMP87CM41F Outdoor UnitRY-4WAY RY-LIQ RY-GAS RY-FANL RY-FANH Indoor Unit Outdoor Unit Wiring DiagramMMC24FA-1 Bottom View Component LocationsDisplay Assembly Split Type 6871A20680 Component side Solder side Refrigeration Cycle Diagram Troubleshooting GuideMMC18FA-1 MMH18FA-1MMH24FA-1 MMH36FA-1 MMC36FA-1Outdoor Error Indoor ErrorError Indicator Self-diagnosis FunctionTrouble analysis Cycle Troubleshooting GuideProcedure Specification Remedy Electronic Parts Troubleshooting GuideProduct doesnt operate with the remote controller Check Point Comp. on Comp. OFF Compressor/Outdoor Fan dont operateNector Trouble 4 When indoor Fan does not operateRY-COMP-B Voltage of Connectors according to Indoor Fan SpeedWhen Vertical Louver does not operate Check Point Error CodeIndoor air sensor Indoor inlet pipe sensorCommunication line is shorted at GND Description Cause of error Check point & Normal conditionPower input AC 230V.Outdoor, Indoor Comp OFF Pipe sensor Outdoor air sensorCondensor pipe sensor Way Valve Liguid Side Way, 3-way ValvePumping down ProcedureAll the refrigerant leaked Replace the valve and service port capsEvacuation Gas Charging Replace the valve stem nuts and the service port nutAfter Evacuation Connect the gauge to the charging cylinderModel B-MMC09FA-1, B-MMH09FA-1, B-MMC12FA-1, B-MMH12FA-1 Exploded ViewModel A-MMC18FA-1, A-MMH18FA-1 Model A-MMC24FA-1, A-MMH24FA-1 Model A-MMC36FA-1, A-MMH36FA-1 08/06/2008 Heat CONTROLLER, INC