Heat Controller A-MMC24FA-1, B-MMH12FA-1, B-MMC12FA-1, B-MMC09FA-1, B-MMH09FA-1 MMC24FA-1 MMH24FA-1

Page 17

Product Specifications

 

Model

 

A-MMC24FA-1

A-MMH24FA-1

 

 

 

 

 

 

Cooling Capacity

 

 

Btu/hr

24,000

24,000

 

 

 

 

 

 

 

 

 

W

7,033

7,033

 

 

 

kcal/hr

6,037

6,037

 

 

 

 

 

 

Heating Capacity

 

 

Btu/hr

-

24,000

 

 

 

W

-

7,033

 

 

 

 

 

 

 

 

 

kcal/hr

-

6,037

Input

Cooling

 

W

2,526

2,526

 

 

 

 

 

 

 

Heating

 

W

-

2440

Running Current(208/230V)

Cooling

 

A

11.4

11.4

 

 

 

 

 

 

 

Heating

 

A

-

11.1

Power Supply

 

 

Ø,V,Hz

1,208/230,60

1,208/230,60

 

 

 

 

 

 

Max. Number of Connectable Indoor Units

 

2

2

Compressor

Type

 

Rotary

Rotary

 

 

 

 

 

 

(Constant)

Model

 

GK094K

GK094K

 

Motor Type

 

Hermetic

Hermetic

 

 

 

 

 

 

 

Quantity

 

Ea

1

1

 

Motor Input

 

W

955

955

 

 

 

 

 

 

 

Oil Charge

 

cc

330±10

330±10

 

Oil Type

 

FVC68D

FVC68D

 

 

 

 

 

 

 

Capacitor

 

µF/Vac

30 / 370

30 / 370

 

O.L.P Type(model name)

 

External Type(MRA98996-12026)

External Type(MRA98996-12026)

 

 

 

 

 

 

Compressor

Type

 

Rotary

Rotary

(Constant)

Model

 

GK141K

GK141K

 

 

 

 

 

 

 

Motor Type

 

Hermetic

Hermetic

 

Quantity

 

Ea

1

1

 

 

 

 

 

 

 

Motor Input

 

W

1430

1,430

 

Oil Charge

 

cc

350±10

350±10

 

 

 

 

 

 

 

Oil Type

 

FVE

FVE

 

Capacitor

 

µF/Vac

35 / 370

35 / 370

 

O.L.P Type(model name)

 

External Type(MRA12105-12026)

External Type(MRA12105-12026)

Refrigerant charge

Charge

 

oz(g)

56.4(1,600)

56.4(1,600)

 

 

 

 

 

 

 

Type

 

R410A

R410A

 

Control

 

EEV

EEV

 

 

 

 

 

 

Coil

Tube Size (OD)

 

inch(mm)

0.276(7.0)

0.276(7.0)

 

Fins per inch

 

18

18

 

 

 

 

 

 

 

No. of Rows & Column/No.

 

2R,36C

2R,36C

Fan motor

Model

 

IC-1640LG GE

IC-1640LG GE

 

 

 

 

 

 

 

Output

 

W

90

90

 

Capacitor

 

µF/Vac

6/370

6/370

 

 

 

 

 

 

Fan

Type

 

Propeller

Propeller

 

No. Used / Diameter

 

CFM(CMM)

1 / 460

1 / 460

 

 

 

 

 

 

 

Discharge

 

Side / Top

Side

Side

Air Circulation

Outdoor

 

CMM(CFM)

1872(53)

1872(53)

Noise Level(H/L) at 230V

Sound Press,1m

 

dB(A) 1

54

54

Defrosting

 

 

 

-

Invertion Cycle

 

 

 

 

 

 

SVC Valve

Liquid

 

inch(mm)

1/4 (6.35) * 2EA

1/4 (6.35) * 2EA

 

 

 

 

3/8 (9.52) * 2EA

3/8 (9.52) * 2EA

 

Gas

 

 

Dimensions

W*H*D

 

inch(mm)

34.3*31.8*12.6 (870*808*320)

34.3*31.8*12.6 (870*808*320)

Net Weight

Outdoor

 

lbs(kg)

141.1(64)

141.1(64)

 

 

 

 

 

 

Max. Interunit Piping Length

Total of Each Room

 

ft(m)

98.4(30)

98.4(30)

 

For One Room

 

ft(m)

49.2(15)

49.2(15)

 

 

 

 

 

 

Max. Installation

Indoor Unit~Outdoor Unit

 

ft(m)

24.6(7.5)

24.6(7.5)

Height Difference

Indoor Unit~Indoor Unit

 

ft(m)

24.6(7.5)

24.6(7.5)

 

 

 

 

 

 

Packing Dimension

W*H*D

 

inch(mm)

40.2*34.3*17.2 (1022*870*437)

40.2*34.3*17.2 (1022*870*437)

Stuffing Quantity

 

 

20/40ft

54/114

54/114

SEER

 

 

 

13.0

13.0

HSPF

 

 

 

-

7.7

Note:

1. Capacities are based on the following conditions:

Cooling:

- Indoor Temperature 26.7˚C(80˚F) DB/19.4˚C(67˚F) WB

 

- Outdoor Temperature 35˚C(95˚F) DB/23.9˚C(75˚F) WB

Heating:

- Indoor Temperature 21.1˚C(70˚F) DB/15.6˚C(60˚F) WB

 

- Outdoor Temperature 8.3˚C(47˚F) DB/6.1˚C(43˚F) WB

Piping Length

- Interconnecting Piping Length 24.6 ft(7.5m)

 

- Level Difference of Zero

2.Wiring cable size must comply with the applicable local and national code.

3.Capacities are Net Capacities.

4.The specification may be subject to change without prior notice for purpose of improvement.

- 17 -

Service Manual

Image 17
Contents Heat CONTROLLER, INC Table of Contents KBtu/h 3 rooms Symbols Used in this ManualKBtu/h 2 rooms Installation Safety PrecautionsBe sure not to do Be sure to follow the instruction Control box securely Cuit and breakerDo not install the product on a Do not install, remove, or reDefective installation stand Do not allow water to run into electric partsFlooded or submerged, contact When the product is soaked Be cautious that water canNever enter the product Use two or more people to lift and transport the product Install the drain hose to ensure that Keep level even whenInstalling the product Operational Do not use the remote is the batteries have leaked Selecting the locationOutdoor Unit Seaside applications and installationSplit Type Indoor DimensionsIndoor Unit 18kBtu/h Outdoor Unit24kBtu/h 36kBtu/h UE2Indoor Unit Type Wall Mounted Model Product SpecificationsMMC18FA-1 MMH18FA-1 Outdoor Unit Multiple piping modelsMMC24FA-1 MMH24FA-1 MMC36FA-1 MMH36FA-1 Installation Tools InstallationInstallation Parts Selecting the best location 18 / 24 kBtu/h KBtu/h Piping length and elevationMulti Piping Type Drilling the hole in the wall Installing Installation PlateStandard TypeFlaring work Flaring Work and Connection of PipingIndoor Connecting the PipingCheck Wrap the insulation material around the all connections Indoor unit installationFor left rear piping Wrap the insulation material around the connecting por- tion Bad case Good caseRemote Control Preparationoptional Outdoor unit 36 kBtu/h OutdoorOutdoor unit 18/24 kBtu/h Tions ETL recognized and CSA certified Connect the cable to the Indoor unitOutdoor unit Connect the cable to the Outdoor unitHow to connect wiring to the terminals Methods of connecting the cableModel Drain piping Checking the drainageTo check the drainage Insulating the Pipe and Special Piping Applications Secure the taped piping along the exterior wall usingLeak checking Air Purging and EvacuationPreparation Leakage testFinishing the job Repeat evacuation procedure for each indoor unitEvacuation Additional ChargingSplit Type Test RunningSoft Dry Operation Mode Cooling Mode OperationHeating Mode Operation OperationFuzzy Operation for Cooling Defrost ControlHeatingFuzzy Operation Off-Timer Operation On-Timer OperationAirflow Speed Selection Fuzzy Operation for DehumidificationSleep Timer Operation Off-Timer = On-Timer OperationChaos Swing Mode Chaos Natural Wind ModeBuzzer Sound Forced OperationSplit Type Indoor Unit Function of Indoor UnitFunction of Outdoor Unit Cooling Model , Heat Pump Model Remote Control OperationTime Setting Buttons Used to adjust the time To remove the Grille from the Chassis DisassemblyTo remove the Control Box To remove the Motor Cover Indoor Unit Schematic DiagramElectronic Control Device TMP87CM41F Outdoor UnitRY-4WAY RY-LIQ RY-GAS RY-FANL RY-FANH Indoor Unit Outdoor Unit Wiring DiagramMMC24FA-1 Bottom View Component LocationsDisplay Assembly Split Type 6871A20680 Component side Solder side Refrigeration Cycle Diagram Troubleshooting GuideMMC18FA-1 MMH18FA-1MMH24FA-1 MMH36FA-1 MMC36FA-1Outdoor Error Indoor ErrorError Indicator Self-diagnosis FunctionTrouble analysis Cycle Troubleshooting GuideProcedure Specification Remedy Electronic Parts Troubleshooting GuideProduct doesnt operate with the remote controller Check Point Comp. on Comp. OFF Compressor/Outdoor Fan dont operateNector Trouble 4 When indoor Fan does not operateRY-COMP-B Voltage of Connectors according to Indoor Fan SpeedWhen Vertical Louver does not operate Check Point Error CodeIndoor air sensor Indoor inlet pipe sensorCommunication line is shorted at GND Description Cause of error Check point & Normal conditionPower input AC 230V.Outdoor, Indoor Comp OFF Pipe sensor Outdoor air sensorCondensor pipe sensor Way Valve Liguid Side Way, 3-way ValvePumping down ProcedureAll the refrigerant leaked Replace the valve and service port capsEvacuation Gas Charging Replace the valve stem nuts and the service port nutAfter Evacuation Connect the gauge to the charging cylinderModel B-MMC09FA-1, B-MMH09FA-1, B-MMC12FA-1, B-MMH12FA-1 Exploded ViewModel A-MMC18FA-1, A-MMH18FA-1 Model A-MMC24FA-1, A-MMH24FA-1 Model A-MMC36FA-1, A-MMH36FA-1 08/06/2008 Heat CONTROLLER, INC