Operation
FunctionofIndoorUnit
Split Type Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
•Room temperature sensor. (THERMISTOR)
Room temperature control
•Maintains the room temperature in accordance with the set point Temp.
Starting Current Control
•Indoor fan is delayed for 5 seconds at the starting.
Time Delay Safety Control
•Restarting is delayed for approx. 3 minutes.
Indoor Fan Speed Control
•High, Med, Low, Chaos, Jet Cool
Operation indication Lamps (LED)
On/Off : Lights up during the system operation.
Sleep Mode : Lights up during Sleep Mode Auto operation.
Timer | : Lights up during Timer operation. |
Defrost Mode : Lights up during Defrost Mode or Hot Start operation (Heat pump model only)
Outdoor unit : Lights up during outdoor unit operation.(Cooling model only) operation
Desire temperature For cooling,dehumidification,heating modes it display Destired temperature
indicator | • Cooling | : 18°C~30°C(64°F~86°F) |
| • AI | : Auto Operation |
| |||||
| • Dehumidification | : 18°C~30°C(64°F~86°F) |
| • Po | : Jet Cool |
| • Heating | : 16~30°C(60°F~86°F) |
| • Lo | : Test Mode |
Soft Dry Operation Mode
•Intermittent operation of fan at low speed.
Sleep Mode Auto Control
•The fan is switched to low(Cooling), med(Heating) speed.
•The unit will be stopped after user selected1, 2, 3, 4, 5, 6, 7 hours.
Natural Air Control by CHAOS Logic
•The fan is switched to intermittent or irregular operation
•The fan speed is automatically switched from high to low speed.
* Airflow Direction Control
•The louver can be set at the desired position or swing up and down automatically.(Model base)
"Wall Mounted Type is standard"
* Functions is dependent on model type.
•Both the indoor and outdoor fans stop during
•Hot start after
Hot-start Control (Heating)
•The indoor fan stops until the
evaporator piping temperature reaches 27°C(80.6°F).
Wall Mounted | - 46 - |