Heat Controller A-MMC18FA-1, B-MMH12FA-1, B-MMC12FA-1, B-MMC09FA-1, B-MMH09FA-1 MMC36FA-1 MMH36FA-1

Page 18

Product Specifications

 

Model

 

A-MMC36FA-1

A-MMH36FA-1

 

 

 

 

 

 

Cooling Capacity

 

 

Btu/hr

36,000

36,000

 

 

 

W

10,550

10,500

 

 

 

kcal/hr

9,071

9,071

 

 

 

 

 

 

Heating Capacity

 

 

Btu/hr

-

36,000

 

 

 

 

 

 

 

 

 

W

-

10,500

 

 

 

kcal/hr

-

9,071

Input

Cooling

 

W

4,045

4,045

 

 

 

 

 

 

 

Heating

 

W

-

3340

Running Current(208/230V)

Cooling

 

A

18.2

18.2

 

Heating

 

A

-

17.9

Power Supply

 

 

Ø,V,Hz

1,208/230,60

1,208/230,60

 

 

 

 

 

 

Max. Number of Connectable Indoor Units

 

3

3

Compressor

Type

 

Rotary

Rotary

(Constant)

Model

 

GK141K

GK141K

 

Motor Type

 

 

2 Pole Induction(PSC)

2 Pole Induction(PSC)

 

 

 

 

 

 

 

Quantity

 

Ea

1

1

 

Motor Input

 

W

1430

1430

 

Oil Charge

cc

350Å}10

350Å}10

 

 

 

 

 

 

 

Oil Type

 

FVC68D

FVC68D

 

 

 

 

 

 

 

Capacitor

 

µF/Vac

35 / 370

35 / 370

 

O.L.P Type(model name)

 

External Type

External Type

Compressor

Type

 

Rotary

Rotary

 

 

 

 

 

 

(Constant)

Model

 

GJ230K

GJ230K

 

Motor Type

 

2 Pole Induction(PSC)

2 Pole Induction(PSC)

 

Quantity

 

Ea

1

1

 

Motor Input

 

W

2370

2370

 

 

 

 

 

 

 

Oil Charge

 

cc

700±10

7000±10

 

Oil Type

 

FVC68D

FVC68D

 

Capacitor

 

µF/Vac

50 / 400

50 / 400

 

 

 

 

 

 

 

O.L.P Type(model name)

 

Internal Type

Internal Type

 

 

 

 

 

 

Refrigerant charge

Charge

 

oz(g)

84.7(2400)

84.7(2400)

 

Type

 

R410A

R410A

 

Control

 

EEV

EEV

 

 

 

 

 

 

Coil

Tube Size (OD)

 

inch(mm)

0.276(7.0)

0.276(7.0)

 

 

 

 

 

 

 

Fins per inch

 

18

18

 

No. of Rows & Column/No.

 

2R,48C

2R,48C

Fan motor

Model

 

ARC286B01 * 2

ARC286B01 * 2

 

Output

 

W

102

102

 

Capacitor

 

µF/Vac

2/370

2/370

Fan

Type

 

Propeller

Propeller

 

No. Used / Diameter

 

EA/inch(mm)

2 / 15.7(400)

2 / 15.7(400)

 

 

 

 

 

 

 

Discharge

 

Side / Top

Side

Side

Air Circulation

Outdoor

 

CFM(CMM)

2225(63)

2225(63)

Noise Level(H/L) at 230V

Sound Press,1m

 

dB(A) 1

51

51

 

 

 

 

 

 

SVC Valve

Liquid

 

inch(mm)

1/4 (6..35) * 3EA

1/4 (6..35) * 3EA

 

 

 

 

 

 

 

Gas

 

 

3/8 (9.52) * 3EA

3/8 (9.52) * 3EA

Dimensions

W*H*D

 

inch(mm)

34.3*40.7*12.6 (870*1038*320)

34.3*40.7*12.6 (870*1038*320)

Net Weight

Outdoor

 

lbs(kg)

185.2(84)

185.2(84)

 

 

 

 

 

 

Max. Interunit Piping Length

Total of Each Room

 

ft(m)

147.6(45)

147.6(45)

 

 

 

 

 

 

 

For One Room

 

ft(m)

49.2(15)

49.2(15)

Max. Installation

Indoor Unit~Outdoor Unit

 

ft(m)

24.6(7.5)

24.6(7.5)

Height Difference

Indoor Unit~Indoor Unit

 

ft(m)

24.6(7.5)

24.6(7.5)

 

 

 

 

 

 

Packing Dimension

W*H*D

 

inch(mm)

41.3*44.9*17.3 (1048*1140*439)

41.3*44.9*17.3 (1048*1140*439)

Stuffing Quantity

 

 

20/40ft

53/111

53/111

SEER

 

 

 

13.0

13.0

HSPF

 

 

 

-

7.7

Note:

1. Capacities are based on the following conditions:

Cooling:

- Indoor Temperature 26.7˚C(80˚F) DB/19.4˚C(67˚F) WB

 

- Outdoor Temperature 35˚C(95˚F) DB/23.9˚C(75˚F) WB

Heating:

- Indoor Temperature 21.1˚C(70˚F) DB/15.6˚C(60˚F) WB

 

- Outdoor Temperature 8.3˚C(47˚F) DB/6.1˚C(43˚F) WB

Piping Length

- Interconnecting Piping Length 24.6 ft(7.5m)

 

- Level Difference of Zero

2.Wiring cable size must comply with the applicable local and national code.

3.Capacities are Net Capacities.

4.The specification may be subject to change without prior notice for purpose of improvement.

Wall Mounted Multi-Zone Split System Air Conditioner

- 18 -

Image 18
Contents Heat CONTROLLER, INC Table of Contents Symbols Used in this Manual KBtu/h 2 roomsKBtu/h 3 rooms Be sure not to do Be sure to follow the instruction Safety PrecautionsInstallation Control box securely Cuit and breakerDefective installation stand Do not install, remove, or reDo not install the product on a Do not allow water to run into electric partsWhen the product is soaked Be cautious that water can Never enter the productFlooded or submerged, contact Install the drain hose to ensure that Keep level even when Installing the productUse two or more people to lift and transport the product Operational Do not use the remote is the batteries have leaked Seaside applications and installation Selecting the locationOutdoor UnitDimensions Indoor UnitSplit Type Indoor Outdoor Unit 18kBtu/h24kBtu/h UE2 36kBtu/hProduct Specifications Indoor Unit Type Wall Mounted ModelOutdoor Unit Multiple piping models MMC18FA-1 MMH18FA-1MMC24FA-1 MMH24FA-1 MMC36FA-1 MMH36FA-1 Installation Installation PartsInstallation Tools Selecting the best location Piping length and elevation Multi Piping Type18 / 24 kBtu/h KBtu/h Installing Installation PlateStandard Type Drilling the hole in the wallFlaring Work and Connection of Piping Flaring workConnecting the Piping CheckIndoor Indoor unit installation Wrap the insulation material around the all connectionsFor left rear piping Wrap the insulation material around the connecting por- tion Good case Bad caseRemote Control Preparationoptional Outdoor Outdoor unit 18/24 kBtu/hOutdoor unit 36 kBtu/h Connect the cable to the Indoor unit Tions ETL recognized and CSA certifiedConnect the cable to the Outdoor unit Outdoor unitMethods of connecting the cable How to connect wiring to the terminalsModel Checking the drainage To check the drainageDrain piping Secure the taped piping along the exterior wall using Insulating the Pipe and Special Piping ApplicationsPreparation Air Purging and EvacuationLeak checking Leakage testRepeat evacuation procedure for each indoor unit EvacuationFinishing the job Charging AdditionalTest Running Split TypeHeating Mode Operation Cooling Mode OperationSoft Dry Operation Mode OperationDefrost ControlHeating Fuzzy OperationFuzzy Operation for Cooling Airflow Speed Selection On-Timer OperationOff-Timer Operation Fuzzy Operation for DehumidificationChaos Swing Mode Off-Timer = On-Timer OperationSleep Timer Operation Chaos Natural Wind ModeForced Operation Buzzer SoundFunction of Indoor Unit Split Type Indoor UnitFunction of Outdoor Unit Remote Control Operation Time Setting Buttons Used to adjust the timeCooling Model , Heat Pump Model Disassembly To remove the Grille from the ChassisTo remove the Control Box To remove the Motor Cover Schematic Diagram Electronic Control DeviceIndoor Unit Outdoor Unit TMP87CM41FRY-4WAY RY-LIQ RY-GAS RY-FANL RY-FANH Wiring Diagram Indoor Unit Outdoor UnitMMC24FA-1 Component Locations Bottom ViewDisplay Assembly Split Type 6871A20680 Component side Solder side MMC18FA-1 Troubleshooting GuideRefrigeration Cycle Diagram MMH18FA-1MMH24FA-1 MMC36FA-1 MMH36FA-1Error Indicator Indoor ErrorOutdoor Error Self-diagnosis FunctionCycle Troubleshooting Guide Trouble analysisElectronic Parts Troubleshooting Guide Procedure Specification RemedyProduct doesnt operate with the remote controller Compressor/Outdoor Fan dont operate Check Point Comp. on Comp. OFFTrouble 4 When indoor Fan does not operate NectorVoltage of Connectors according to Indoor Fan Speed RY-COMP-BWhen Vertical Louver does not operate Indoor air sensor Error CodeCheck Point Indoor inlet pipe sensorDescription Cause of error Check point & Normal condition Power input AC 230V.Outdoor, IndoorCommunication line is shorted at GND Comp OFF Outdoor air sensor Condensor pipe sensorPipe sensor Way, 3-way Valve Way Valve Liguid SideProcedure Pumping downReplace the valve and service port caps EvacuationAll the refrigerant leaked After Evacuation Replace the valve stem nuts and the service port nutGas Charging Connect the gauge to the charging cylinderExploded View Model B-MMC09FA-1, B-MMH09FA-1, B-MMC12FA-1, B-MMH12FA-1Model A-MMC18FA-1, A-MMH18FA-1 Model A-MMC24FA-1, A-MMH24FA-1 Model A-MMC36FA-1, A-MMH36FA-1 Heat CONTROLLER, INC 08/06/2008