Operating Instructions

Heating Operation(Heat pump model only)

1

Press the Start/Stop button.

The unit will respond with

beep sound.

ON

2

Open the door on the Remote Controller. To select Heating

Operation, press the Operation Mode Selection button.

Each time the button is pressed, the operation mode is shifted in the direction of the arrow.

Cooling

Auto

Healthy

Heating

 

 

Dehumidification (Heat pump model only)

3

Set the temperature higher than the room temperature.

The temperature can be set within a range

 

of16°C~30°C(60°F~86°F) in 1°C(2°F).

 

To raise the temperature

 

To lower the temperature

4 Set the fan speed again. You can select the fan speed in four steps–low, medium, high, or CHAOS. Each time the button is pressed, the fan speed mode is shifted.

NATURAL WIND BY THE CHAOS LOGIC

For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic.

Owner's Manual 15

Image 15
Contents Important Information Heat CONTROLLER, INCTable of Contents Safety Precautions Do not allow water to run into electric part Do not handle the pipe by yourselfCostomerThere could result in personal injury and product damage There is risk of electrical shockThere is risk of fire or electrical ShockEnsure that water is drained Always check for Install the drain hose toInstallation or repair Away properly Product Do not install the productThey may burn or explode There is risk of personal injuryThere is risk of personal injury and failure of product Be careful and avoid personal injuryPrior to operation Remote Controller Storage and Tips For Using the Remote ControllerOperating Instructions Signal Receptor Remote Control Operation Signal transmitterNd F Button Cooling Operation Set the temperature lower than the room temperatureAuto Operation Temperature and fan speed are automatically set byFan speed mode is shifted Healthy Dehumidification OperationSound Of16C~30C60F~86F in 1C2F Temperature can be set within a rangeHeating OperationHeat pump model only Beep soundUnit will operate in high fan speed in cooling/heating mode Jet CoolOr or 2nd F Operation Delay Start/Pre-Set Stop Additional featuresSleep Mode Setting the TimeVertical Airflow Direction Control Air Circulation ModeAuto clean Forced OperationHeat pump Model Quickly Auto restartVolatile substances Maintenance and ServiceIndoor Unit DiscolorationClosed Uniform When the air conditioner is to be used againClean the air filter regularly Do not overcool the room Keep blinds or curtainsCase Explanation See TroubleshootingHeat CONTROLLER, INC