Maintenance and Service

Auto restart

In case the power comes on again after a power failure, the unit operates automatically to the previous operating conditions.

So there is no need of activating this function by pressing any key or button.

In the initial mode, the fan operates at a low speed and the compressor starts about 3 minutes later. As the compressor starts, the fan speed also resumes its previous setting mode.

In case of absence for a long time while power failure, turn off main power to avoid undersired Auto restart.

NOTICE

This feature is enabled by factory default setting, but you can disable it by pressing the ON/OFF button for 6 seconds. The unit will beep twice and the indicator lamp(2) will blink 4 times.

To enable it, press the button again for 6 seconds. The unit will beep twice and the indicator lamp(1) will blink 4 times.

ON/OFF

button

Helpful information

Fan speed and cooling capacity.

The cooling/heating capacity indicated in the specification is the value

when the fan speed is set to high, and the capacity will be lower at

low or medium fan speed.

High

High fan speed is recommended when you wish to cool/heat the room

Speed

quickly.

 

Owner's Manual 21

Image 21
Contents Important Information Heat CONTROLLER, INCTable of Contents Safety Precautions Do not allow water to run into electric part Do not handle the pipe by yourselfCostomerThere is risk of fire or electrical There is risk of electrical shockShock There could result in personal injury and product damageInstallation or repair Away properly Product Always check for Install the drain hose toDo not install the product Ensure that water is drainedThere is risk of personal injury and failure of product There is risk of personal injuryBe careful and avoid personal injury They may burn or explodePrior to operation Remote Controller Storage and Tips For Using the Remote ControllerOperating Instructions Signal Receptor Remote Control Operation Signal transmitterNd F Button Cooling Operation Set the temperature lower than the room temperatureAuto Operation Temperature and fan speed are automatically set byFan speed mode is shifted Healthy Dehumidification OperationSound Heating OperationHeat pump model only Temperature can be set within a rangeBeep sound Of16C~30C60F~86F in 1C2FUnit will operate in high fan speed in cooling/heating mode Jet CoolOr or 2nd F Operation Sleep Mode Additional featuresSetting the Time Delay Start/Pre-Set StopVertical Airflow Direction Control Air Circulation ModeAuto clean Forced OperationHeat pump Model Quickly Auto restartIndoor Unit Maintenance and ServiceDiscoloration Volatile substancesClean the air filter regularly When the air conditioner is to be used againDo not overcool the room Keep blinds or curtains Closed UniformCase Explanation See TroubleshootingHeat CONTROLLER, INC