Haier AD142XLERA Instructions to installation, Pipe and insulation material, Hose, Requirement

Page 21
Pipe and insulation material

Hose Instructions to installation

 

Pipe and insulation material

 

 

Pipe

Rigid PVC pipe VP31.5mm (internal diameter)

 

 

Insulation

Foamed PE with thickness above 7mm

 

 

 

 

 

Hose

Drain pipe size: ÿ19.05mm2 (3/4") PVC pipe.

The hose is used for adjusting the off-center and angle of the rigid PVC pipe.

Directly stretch the hose to install without making any deformation.

The soft end of the hose must be fastened with a hose clamp.

 

Please apply the hose on horizontal part

Hose

 

Insulation treatment:

Wrap the hose and its clamp until to the indoor unit without any clearance with insulating material, as shown in the figure.

Subsidiary insulation

Hose clamp

Insulation

Rigid PVC pipe

Drain confirmation

During trial run, check that there is no leakage at the pipe connection part during water draining even in winter.

Allowable pipe length and drop

These parameters differ according to the outdoor unit. See the instruction manual attached with the outdoor unit for details.

Supplementary refrigerant

The refrigerant supplementation shall be as specified in the installation instructions attached with the outdoor unit. The added refrigerant shall be R22.

The adding procedure shall be aided with a measuring meter for a specified amount of supplemented refrigerant

Requirement

Overfilling or underfilling of refrigerant will cause compressor fault. The amount of the added refrigerant shall be as specified in the instructions.

Pipe cutting and expanding

If the pipe is too long or the flare is damaged, it needs to be cut or expanded.

1. Pipe cutting

2. Removing burrs

3.Insertion nut

4. Pipe expansion

19

Image 21
Contents No.0010577705 AD092XLERA AD122XLERA AD142XLERA AD182XLERAR410A MULTI SPLIT SERIES ROOM AIR CONDITIONER Safety precautions ContentsNotes for safety Trouble shootingSafety Instructions and Warnings CautionsDisposal of the old air conditioner Cautions SpecificationsSafety precautions Safety precautions CAUTIONSSafety precautions CAUTIONS ON INSTALLATIONWiring LocationNotes for safety INDOOR UNIT Parts and FunctionsThe followings are not malfuncition Trouble shootingTrouble shooting Unit fails to startCustomer Need-to-know Using DirectionsCooled air blown out when heating When trouble happensInsufficient cooling or heating Insufficient cooling1. Safety precautions Instructions to installationPRECAUTION 2. Preparation for installationInstructions to installation 4. Choose the installation place 3. Accessories for installation5.Installation procedure Instructions to installationa h g Instructions to installationInstallation for air duct of indoor unit 1. Installation of air discharge ductInstructions to installation 3. Air duct insulation 2. Installation of air return ductInstructions to installation Installing the suspension screwInstructions to installation RequirementsOriginal concrete slab Steel reinforcement structurePipe and insulation material Instructions to installationHose Insulation treatmentPipe expansion dimensions as follows Instructions to installationConnecting pipe Installing torque2.Installation check and trial operation 1. Indoor unit communication addresses setting3.Installation check Instructions to installationWiring methods 4.Trial operationInstructions to installation Instructions to installation Failure code4 Wiring of indoor unit Communication cable Shield wire H05RN-F2X1.5 mm2Failure code 3.Failrue codes maked with * are resumable Failure codeHAIER GROUP