CAUTIONS ON INSTALLATION

[Location] Safety precautions

CAUTIONS ON INSTALLATION

Please ask the dealer or specialist to install, never try by the users themselves. After the installation please be sure of the following conditions.

[Wiring] Please call dealer to install the air-conditioner.

Incorrect installation may cause water leaking, shock and fire hazard.

CAUTION !

[Operating noise] Air-conditioner can't be installed in the envi-ronment with inflammable gases because the inflammable gases near to air-conditioner may cause fire hazard.

Manual background Connect earthing wire.

Earthing wire should not be con- nected to the gas pipe, water

pipe, lightning rod or phone line,

Earthing

Manual background Installed electrical-leaking circuit breaker.

It easily cause electrical shock without circuit breaker.

[Location]

Manual background Air-conditioner should be located in well-vented and easily-accessible place.

Manual background Air-conditioner should not be located in the following places:

(a)Places with machine oils or other oil vapours.

(b)Seaside with high salt content in the air.

(c)Near to hot spring with high content of sulfide gases.

(d)Area with frequent fluctuation of voltage e.g. factory, etc.

(e)In vehicles or ships.

(f)Kitchen with heavy oil vapour or humidity.

(g)Near to the machine emitting electric- magnetic waves.

(h)Places with acid, alkali vapuor.

Manual background TV, radio, acoustic appliances etc are at least 1 m far away to the indoor unit, outdoor unit, power supply wire, connecting wire, pipes, otherwise images may be disturbed or noises be created.

in-correct earthing may cause shock.

Manual background Use discharge pipe correctly to ensure efficient discharge.

Incorrect pipe use may cause water leaking.

Manual background As required, take measures against heavy snow.

[Wiring]

Manual background Air-conditioner should be equipped with special power supply wire.

[Operating noise]

Manual background Chose the following locations:

(a)Capable of supporting air-conditioner weight, don't increase operating noise and vibration.

(b)Hot vapour from outdoor unit outlet and operating noise don't disturb neighbour.

Manual background No obstacles around the outdoor unit outlet.

5

Image 7
Contents AD092XLERA AD122XLERA AD142XLERA AD182XLERA No.0010577705R410A MULTI SPLIT SERIES ROOM AIR CONDITIONER Trouble shooting ContentsSafety precautions Notes for safetyCautions Safety Instructions and WarningsDisposal of the old air conditioner Cautions SpecificationsSafety precautions Safety precautions CAUTIONSLocation CAUTIONS ON INSTALLATIONSafety precautions WiringNotes for safety INDOOR UNIT Parts and FunctionsThe followings are not malfuncition Trouble shootingTrouble shooting Unit fails to startCustomer Need-to-know Using DirectionsInsufficient cooling When trouble happensCooled air blown out when heating Insufficient cooling or heating1. Safety precautions Instructions to installation2. Preparation for installation PRECAUTIONInstructions to installation Instructions to installation 3. Accessories for installation4. Choose the installation place 5.Installation procedurea h g Instructions to installation1. Installation of air discharge duct Installation for air duct of indoor unitInstructions to installation Installing the suspension screw 2. Installation of air return duct3. Air duct insulation Instructions to installationSteel reinforcement structure RequirementsInstructions to installation Original concrete slabInsulation treatment Instructions to installationPipe and insulation material HoseInstalling torque Instructions to installationPipe expansion dimensions as follows Connecting pipeInstructions to installation 1. Indoor unit communication addresses setting2.Installation check and trial operation 3.Installation check4.Trial operation Wiring methodsInstructions to installation Communication cable Shield wire H05RN-F2X1.5 mm2 Failure codeInstructions to installation 4 Wiring of indoor unitFailure code 3.Failrue codes maked with * are resumable Failure codeHAIER GROUP