Haier AD122XLERA, AD182XLERA, AD142XLERA, AD092XLERA installation manual Cautions, Safety precautions

Page 6
CAUTIONS!

Manual background Safety precautions

CAUTIONS!

Manual background Conditioner should not be used for any other purpose other than airconditioning.

Don't use air-conditioner for any other special purposes, e.g. the preservation and protection of food, animals, plants, pecision apparatus as well as work of art, otherwise the qualities of these stuffs may be damaged.

Manual background Don't dismantle the outlet of the outdoor unit.

The exposure of fan is very dangerous which may harm human be- ings.

Manual background When air-conditioner is co-used with other heat-radiator the frequent replacement of room atmosphere should be required.

Inefficient venti- lation may cause suffocation.

Manual background After a long time use of air-conditioner the base should be checked for any damages.

If the damaged base is not repaired, the unit may fall down and cause accidents.

Manual background No goods or nobody is permitted to placed on or stand on outdoor unit.

The falling of goods and people may cause acci- dents.

Manual background Pets and plants should not be blowed directly in the air flow.

Otherwise will suffer damage.

Manual background Don't operate the air-conditioner with damp hands.

Otherwise will be shocked.

Manual background Only use correctly-typed fuse.

May not use wire or any other materials replacing fuse, otherwise may cause faults or fire accidents.

Manual background Don't place any burning unit in the air flow of air-conditioner, which may cause incomplete combustion.

Manual background No inflammable spray fluid should be permitted to be placed or used near to airconditioner other wise may cause fire accidents.

Manual background Air-conditioner should be cleaned only after power supply is cut off to keep from shock or hurt.

Manual background Don't clean air-conditioner with water.

Otherwise may cause shock.

Manual background When use the fumigating insecticide don't open air-conditioner.

Otherwise the poisonous chemicals may settle in air-conditioner which harm the health of chemical-allergic people.

4

Image 6
Contents No.0010577705 AD092XLERA AD122XLERA AD142XLERA AD182XLERAR410A MULTI SPLIT SERIES ROOM AIR CONDITIONER Notes for safety ContentsSafety precautions Trouble shootingSafety Instructions and Warnings CautionsDisposal of the old air conditioner Specifications CautionsSafety precautions CAUTIONS Safety precautionsWiring CAUTIONS ON INSTALLATIONSafety precautions LocationNotes for safety Parts and Functions INDOOR UNITTrouble shooting The followings are not malfuncitionUnit fails to start Trouble shootingUsing Directions Customer Need-to-knowInsufficient cooling or heating When trouble happensCooled air blown out when heating Insufficient coolingInstructions to installation 1. Safety precautionsPRECAUTION 2. Preparation for installationInstructions to installation 5.Installation procedure 3. Accessories for installation4. Choose the installation place Instructions to installationInstructions to installation a h gInstallation for air duct of indoor unit 1. Installation of air discharge ductInstructions to installation Instructions to installation 2. Installation of air return duct3. Air duct insulation Installing the suspension screwOriginal concrete slab RequirementsInstructions to installation Steel reinforcement structureHose Instructions to installationPipe and insulation material Insulation treatmentConnecting pipe Instructions to installationPipe expansion dimensions as follows Installing torque3.Installation check 1. Indoor unit communication addresses setting2.Installation check and trial operation Instructions to installationWiring methods 4.Trial operationInstructions to installation 4 Wiring of indoor unit Failure codeInstructions to installation Communication cable Shield wire H05RN-F2X1.5 mm2Failure code Failure code 3.Failrue codes maked with * are resumableHAIER GROUP