APPENDIX A BLOWER PERFORMANCE TABLES

DIRECT DRIVE

CPG060 HORIZONTAL

CPG060 DIRECT DRIVE HORIZONTAL

SPEED

EXTERNAL STATIC

STANDARD

 

 

 

PRESSURE (ESP)

AMPS

WATTS

RPM

TAP

CFM

in w.c.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.10

1416

1.63

176

588

 

0.20

1295

1.61

174

621

T1

0.30

1200

1.68

186

660

 

0.40

1133

1.79

196

704

 

0.50

1045

1.90

208

753

 

0.10

1543

2.00

220

627

 

0.20

1485

2.12

236

671

T2

0.30

1425

2.20

250

698

 

0.40

1352

2.26

258

748

 

0.50

1304

2.39

274

786

 

0.10

2107

4.02

502

797

 

0.20

2031

4.13

518

819

 

0.30

1980

4.27

536

858

T3

0.40

1954

4.37

554

880

 

0.50

1887

4.48

572

913

 

0.60

1839

4.58

582

940

 

0.70

1782

4.72

602

968

 

0.10

2224

4.73

592

832

 

0.20

2165

4.79

612

860

 

0.30

2123

4.91

630

891

T4

0.40

2079

5.01

642

913

0.50

2029

5.14

666

946

 

0.60

1978

5.26

676

969

 

0.70

1926

5.38

698

1001

 

0.80

1872

5.48

712

1028

 

0.90

1817

5.58

722

1056

 

0.10

2318

5.42

700

874

 

0.20

2296

5.55

720

903

 

0.30

2228

5.66

734

929

 

0.40

2193

5.76

748

950

T5

0.50

2145

5.90

766

979

 

0.60

2097

5.99

784

1012

 

0.70

2054

6.10

798

1034

 

0.80

1991

6.15

810

1050

 

0.90

1952

6.26

826

1079

NOTES:

Tables represent dry coil without filter, to compensate for filter add 0.08" to measured E.S.P. SCFM correction for wet coil = 4 %. 5 Ton models are shipped from the factory with speed tap set on T4.

28

Image 28
Contents CPG Series Replacement Parts Safety InstructionsGeneral Information High VoltageUnit Location Clearances Roof Curb POST-INSTALLATION Checks Roof TOP Duct ConnectionsRigging Details Weights shown are belt drive with no accessories Electrical Wiring Power and Low Voltage Block ConnectionsGAS Supply Piping Areas Without Convenience OutletInlet GAS Pressure Propane GAS Installations GAS Piping ChecksCirculating AIR and Filters Venting Condensate Drain ConnectionSTARTUP, ADJUSTMENTS, and Checks PRE-STARTUP InstructionsThree Phase Models Only Percent voltage unbalance Must not exceed 2%Rollout Protection Control Manifold Pressure Check PSC Motor Normal Sequence of Operation Flame Sensor and Ignition Electrode LocationTroubleshooting Check rollout limitInput Rating AdjustmentInput Btu/Hr = AIR Flow Adjustments Motor Sheave AdjustmentsMaintenance PSC MotorCabinet Finish Maintenance Burner Flame CPG036 Direct Drive Down Shot CPG036 Direct Drive HorizontalCPG048 Direct Drive Down Shot CPG048 Direct Drive HorizontalCPG060 Direct Drive Down Shot CPG060 Direct Drive Horizontal CPG036 Standard Belt Drive Horizontal CPG048 Standard Belt Drive HorizontalCPG060 Standard Belt Drive Horizontal CPG072 Standard Belt Drive Horizontal806 744 CPG036 High Static Belt Drive Down Shot CPG048 High Static Belt Drive Down ShotCPG060 High Static Belt Drive Down Shot CPG072 High Static Belt Drive Down ShotCPG036 High Static Belt Drive Horizontal CPG048 High Static Belt Drive HorizontalCPG060 High Static Belt Drive Horizontal CPG072 High Static Belt Drive HorizontalAppendix B Electrical Data Appendix C Unit Dimensions Appendix D Wiring Diagrams CPG036480451D Single Phase 240V/60HZ Direct Drive IICINSTALLER/SERVICEMAN 208-240/1/60 0140L00510 REV aCPG0360480901D Single Phase 240V/60HZ Direct Drive 208-240/1/60 0140L00506 REV a CPG0060*1D Single Phase 240V/60HZ Direct Drive YL/PK240/1/60 0140L00429 REV B YL PK CPG060*3D Three Phase 208-230V/60HZ DirectS1 TB1 CPG060*3D Three Phase 208-230V/60HZ Direct Drive CPG036048*3D Three Phase 208-230V/60HZ Direct Drive Motor Wires208-240/3/60 0140L00512 REV B CPG036048*3D Three Phase 230V/60HZ Direct Drive 208-240/3/60 0140L00507 REV B 460-575/3/60 0140L00870 REV B 460-575/3/60 0140L00870 REV B Y1 C LPS HPS PLF High Voltage CPG0360480454B Three Phase 575V/60HZ Belt Drive VMR IGNCPG0360480453B Three Phase 240V/60HZ Belt Drive 208-240/3/60 0140L00979 REV B Goodman Manufacturing Company, L.P