Dell SCv2080 manual

Page 22

I/O Card Power (per Slot)

Minimum available

1 W at +5 V (standby)

power

 

 

 

Physical

 

 

 

Height

22.23 cm (8.75 inches)

Width

48.26 cm (19 inches)

Depth

96 cm (38 inches)

Weight (maximum

130 kg (287 lb)

configuration)

 

Weight without drives

62 kg (137 lb)

Environmental

For additional information about environmental measurements for specific storage system configurations, see dell.com/environmental_datasheets.

Temperature

 

Operating

5° to 35°C (41° to 95°F) with a maximum temperature gradation of 10°C per

 

hour

 

NOTE: Maximum 35°C up to 2134 m (7000 ft), derate to 30°C for 2134 m

 

to 3000 m (7000 ft to 10,000 ft)

Storage

–40° to 70°C (–40° to 158°F) with a maximum temperature gradation of 20°C

 

per hour

Relative humidity

 

Operating

20% to 80% (noncondensing) with a maximum humidity gradation of 10% per

 

hour

Storage

5% to 100% (noncondensing)

Maximum vibration

 

Operating

0.21 G at 5–500 Hz for 15 min

Storage

1.04 G at 2–200 Hz for 15 min

Maximum shock

 

Operating

Half-sine shock 5 G +/- 5% with a pulse duration of 10 ms +/- 10% in

 

operational orientations only

Storage

Z-axis: 30 g 10 ms half sine

 

• X- and Y-axes: 20 g 10 ms half sine

Altitude

Operating

–30.5 to 3000 m (–100 to 10,000 ft)

22

Image 22
Contents Dell Storage Center Page Safety Warnings Before You BeginPage Worksheet to Record System Information ISCSI Fault Domain InformationStorage Center Information Additional Storage Center Information Fibre Channel Zoning InformationLocating Your Service Tag Other Information You May NeedInstallation Safety Precautions Installation and ConfigurationSafety Precautions Unpacking Storage Center EquipmentInstalling the Storage System in a Rack SCv2080 Storage System ComponentsInstalling the Hard Drives Mount the SCv2080 Storage System ChassisDdic Front-End Cabling Cabling SAN-Attached Host ServersStorage System Connected to Switches and Host Servers Cabling Direct-Attached Host ServersCabling the Ethernet Management Network Storage System Connected Directly to Host ServersInterconnecting Two Storage Controllers Back-End CablingCabling an Expansion Enclosure to a Storage System Interconnected Storage ControllersConnecting the Power Cables Power Cables Turning on the Storage SystemInstalling and Using the Dell Storage Client Technical SpecificationsNOM Information Mexico Only Page Ddic