Dell SCv2080 manual Ddic

Page 21

LED Indicators

 

• One single-color LED indicator for drawer 2 fault status

Drawer

• One single-color LED indicator for sideplane card and power status

 

• One single-color LED indicator for drawer fault status

 

• One single-color LED indicator for logical fault status

 

• One single-color LED indicator for cable fault status

 

• Six single-color LED indicators for data transfer status

Disk Drive In Carrier

One single-color LED for drive fault status

(DDIC)

 

6 Gb SAS IO module

14 one-color LED status indicators, four each for the three SAS ports and two

 

for the module status

Cooling module

• One single-color LED indicator for module status

 

• One single-color LED indicator for battery fault status (not currently used)

 

• One single-color LED indicator for fan fault status

Power Supply Unit (PSU) • One single-color LED indicator for PSU fault status

One single-color LED indicator for AC power fault status

One single-color LED indicator for power status

Power Supplies

AC power supply (per power supply)

Wattage

2.8 kW

Voltage

200–240 VAC (16 A)

Heat dissipation

191-147 W

Input frequency

50/60 Hz

Max input power

1791 VA

Input current

7.4 A@241 VAC

Maximum inrush current

Under typical line conditions and over the entire system ambient operating

 

range, the inrush current may reach 55 A per power supply for 10 ms or less

 

Available Hard Drive Power (per Slot)

 

 

Supported hard drive

Up to 1.16 A at +5 V

power consumption

Up to 1.6 A at +12 V

(continuous)

 

 

 

I/O Card Power (per Slot)

 

 

 

Maximum power

11 W at +12 V

consumed by I/O Card

 

Maximum available

100 W at +12 V

power

 

21

Image 21
Contents Dell Storage Center Page Before You Begin Safety WarningsPage ISCSI Fault Domain Information Worksheet to Record System InformationStorage Center Information Fibre Channel Zoning Information Additional Storage Center InformationOther Information You May Need Locating Your Service TagSafety Precautions Installation and ConfigurationInstallation Safety Precautions Unpacking Storage Center EquipmentSCv2080 Storage System Components Installing the Storage System in a RackMount the SCv2080 Storage System Chassis Installing the Hard DrivesDdic Cabling SAN-Attached Host Servers Front-End CablingCabling Direct-Attached Host Servers Storage System Connected to Switches and Host ServersStorage System Connected Directly to Host Servers Cabling the Ethernet Management NetworkBack-End Cabling Interconnecting Two Storage ControllersInterconnected Storage Controllers Cabling an Expansion Enclosure to a Storage SystemConnecting the Power Cables Turning on the Storage System Power CablesTechnical Specifications Installing and Using the Dell Storage ClientNOM Information Mexico Only Page Ddic