Dell SCv2080 manual Back-End Cabling, Interconnecting Two Storage Controllers

Page 15

Figure 6. Storage System Connected to a Management Network

1.

Management network switch

2.

SCv2080 storage system

3.

Storage controller 1

4.

Storage controller 2

Back-End Cabling

An SCv2080 storage system may be installed with or without an expansion enclosure.

If you are installing an SCv2080 storage system with an expansion enclosure, you must connect the expansion enclosure to the back-end SAS ports on the storage system.

If you are installing an SCv2080 storage system without an expansion enclosure, you must interconnect back-end SAS ports on the storage system.

NOTE: A storage system with only one storage controller does not support back-end cabling.

Interconnecting Two Storage Controllers

When an SCv2080 with two storage controllers is deployed without expansion enclosures, the storage controllers must be interconnected using SAS cables.

NOTE: The left storage controller is storage controller 1 and the right storage controller is storage controller 2.

1.Connect a SAS cable between storage controller 1: port A and storage controller 2: port B.

2.Connect a SAS cable between storage controller 1: port B and storage controller 2: port A.

15

Image 15
Contents Dell Storage Center Page Before You Begin Safety WarningsPage ISCSI Fault Domain Information Worksheet to Record System InformationStorage Center Information Fibre Channel Zoning Information Additional Storage Center InformationOther Information You May Need Locating Your Service TagUnpacking Storage Center Equipment Installation and ConfigurationSafety Precautions Installation Safety PrecautionsSCv2080 Storage System Components Installing the Storage System in a RackMount the SCv2080 Storage System Chassis Installing the Hard DrivesDdic Cabling SAN-Attached Host Servers Front-End CablingCabling Direct-Attached Host Servers Storage System Connected to Switches and Host ServersStorage System Connected Directly to Host Servers Cabling the Ethernet Management NetworkBack-End Cabling Interconnecting Two Storage ControllersInterconnected Storage Controllers Cabling an Expansion Enclosure to a Storage SystemConnecting the Power Cables Turning on the Storage System Power CablesTechnical Specifications Installing and Using the Dell Storage ClientNOM Information Mexico Only Page Ddic