Dell SCv2080 manual Front-End Cabling, Cabling SAN-Attached Host Servers

Page 12

Front-End Cabling

Front-end cabling refers to the connections between the storage system and host servers. Frontend connections can be made using Fibre Channel, iSCSI, or SAS interfaces.

The storage system connects to switches or connects directly to a host server, depending on the type of front-end ports.

A storage system with Fibre Channel front-end ports connects to one or more FC switches, which connect to one or more host servers.

A storage system with iSCSI front-end ports connects to one or more Ethernet switches, which connect to one or more host servers.

A storage system with a SAS front-end interface connects directly to one or more host servers.

In addition, the MGMT port on each storage controller connects to an Ethernet switch on the management network. This connection to the management network allows configuration, administration, and management of the Storage Center.

For more information, see the Dell Storage Center SCv2080 Storage System Deployment Guide.

Cabling SAN-Attached Host Servers

An SCv2080 storage system with Fibre Channel or iSCSI front-end ports connects to host servers through Fibre Channel or Ethernet switches.

NOTE: The left storage controller is storage controller 1 and the front-end ports are numbered left to right. The right storage controller is storage controller 2 and the front-end ports are numbered left to right.

1.Connect each host server to the switches.

2.Connect fault domain 1 to switch 1.

a.Connect a cable from storage controller 1: port 1 to switch 1.

b.Connect a cable from storage controller 2: port 1 to switch 1.

c.(Four port I/O card only) Connect a cable from storage controller 1: port 3 to switch 1.

d.(Four port I/O card only) Connect a cable from storage controller 2: port 3 to switch 1.

3.Connect fault domain 2 to switch 2.

a.Connect a cable from storage controller 1: port 2 to switch 2.

b.Connect a cable from storage controller 2: port 2 to switch 2.

c.(Four-port I/O card only) Connect a cable from storage controller 1: port 4 to switch 2.

d.(Four-port I/O card only) Connect a cable from storage controller 2: port 4 to switch 2.

12

Image 12
Contents Dell Storage Center Page Safety Warnings Before You BeginPage ISCSI Fault Domain Information Worksheet to Record System InformationStorage Center Information Additional Storage Center Information Fibre Channel Zoning InformationLocating Your Service Tag Other Information You May NeedInstallation and Configuration Safety PrecautionsInstallation Safety Precautions Unpacking Storage Center EquipmentInstalling the Storage System in a Rack SCv2080 Storage System ComponentsInstalling the Hard Drives Mount the SCv2080 Storage System ChassisDdic Front-End Cabling Cabling SAN-Attached Host ServersStorage System Connected to Switches and Host Servers Cabling Direct-Attached Host ServersCabling the Ethernet Management Network Storage System Connected Directly to Host ServersInterconnecting Two Storage Controllers Back-End CablingCabling an Expansion Enclosure to a Storage System Interconnected Storage ControllersConnecting the Power Cables Power Cables Turning on the Storage SystemTechnical Specifications Installing and Using the Dell Storage ClientNOM Information Mexico Only Page Ddic