Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800—833-9353 (WELD).

DESCRIPTION

The following procedure will aid the technician in removing the stator and/or rotor for maintenance or replace- ment of either component.

MATERIALS NEEDED

Lincoln Electric Rotor Removal Kit (S20925) - FOR ROTOR REMOVAL ONLY

5/16” nut driver 1/2” socket wrench 6” socket extension Slot head screw driver 5/8” socket wrench 7/16” socket wrench

7/16” open or box end wrench 3/4” socket or box end wrench 1/2” socket or box end wrench Needle nose pliers Diagonal cutters

Torque wrench (ft lbs)

Babbitt, leather, or wooden mallet Volt/ohmmeter

12” (long) feeler gauge (.010)

INSTRUCTIONS

For stator removal only, follow steps 1 -17 under STATOR REMOVAL PROCEDURE. For reassembly of stator, go to REASSEMBLY PROCEDURE steps 3 - 18.

For rotor removal, follow the STATOR REMOVAL PROCEDURE, ROTOR REMOVAL PROCEDURE, and

REASSEMBLY PROCEDURE.

This procedure takes approximately 3 hours to perform.

POWER-ARC 4000

Image 78
Contents POWER-ARC Safety Depends on YouSafety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion Précautions DE Sûreté Master Table of Contents for ALL Sections Table of Contents Installation Section Installation Technical Specifications POWER-ARCSafety Precautions Location and VentilationStoring PRE-OPERATION Engine Service Spark Arrester Cert. Kool BoreCable Size for Electrical Output ConnectionsWelding Cable Connections 125 ampAuxiliary Power Receptacles Machine GroundingPlugs and HAND-HELD Equipment Premises Wiring Circuit BreakersThese Devices Without POWER-ARC Table of Contents Operation Section Operating Instructions Safety InstructionsOperation General DescriptionRecommended Applications Operational Features and ControlsDesign Features Advantages Welding CapabilityControls and Settings GENERATOR/WELDER ControlsGasoline Engine Controls 20 AMP, 120 Volt Duplex ReceptacleEngine Operation Before Starting the EngineStarting the Engine For a HOT Engine To USE the Generator AS AN Auxiliary Power Supply Generator OperationGeneral Information Table B.1 Generator Power Applications Suggested Power Applications Running Watts Start-up WattsWelding Operation Welding Guidelines Table B.2 Welding APPLICATIONS/ELECTRODE Selection GuideOperation What Happens in the Arc? Correct Welding Position Correct Arc Length Do the following PracticeUse the following Butt WeldsFillet Welds PenetrationVertical-Up Welding Vertical-Down WeldingOverhead Welding Hardfacing To Reduce WearWelding Sheet Metal Welding Cast Iron Cast Iron Plate PreparationHigh-Speed Group AWS E6013 Out-of-Position Group AWS E6011Low Hydrogen Group Stable-Arc E7018 Table of Contents Accessories Section Accessories OPTIONS/ACCESSORIESLincoln Electric Accessories Table of Contents Maintenance Section Engine Maintenance MaintenanceRoutine and Periodic Maintenance Engine AdjustmentsFigure D.2 Clean Rotating SCREEN/FINGER GUARD/DEBRIS Guard Table D.1 Engine Maintenance Schedule GENERATOR/WELDER Maintenance Do not attempt to polish slip rings while engine is runningFigure D.6. Major Component Locations Table of Contents Theory of Operation Section Theory of Operation ENGINE, EXCITATION, Rotor and StatorRotor Field Feedback and Auxiliary Power Figure E.3 Field Excitation and Auxiliary PowerAuxiliary Power Overcurrent Protection Weld Winding and ReactorTable of Contents Troubleshooting & Repair Section Troubleshooting & Repair HOW to USE Troubleshooting GuideTroubleshooting Output ProblemsOr contact your local Lincoln Electric Authorized Field SerVice Facility Field Service Facility Local Lincoln Electric AuthorizedTroubleshooting Rotor Resistance Test Engine Problems Troubleshooting Engine Throttle Adjustment Test Description This procedure takes approximately 15 minutes to performRotor Voltage Test Materials NeededTest Procedure Rotor Voltage TestThis procedure takes approximately 25 minutes to perform Rotor Resistance TestRotor Resistance Test Figure F.3 Brushes Retained with Cable TIE Engine Throttle Adjustment Test This procedure takes approximately 20 minutes to performStrobe-tach Method Frequency Counter MethodOscilloscope Method Wing NUT High Speed Stop Screw Scope Settings Normal Open Circuit Weld Voltage WaveformHigh Idle no Load Normal Open Circuit Voltage Waveform 115 VAC Supply Typical Weld Output Waveform Machine LoadedMachine Loaded to 125 Amps AT 23 VAC Brush Removal and Replacement DescriptionBrush Removal and Replacement ProcedureProcedure Rheostat Removal and Replacement Figure F.7 Rheostat Removal Capacitor AND/OR Diode Bridge Removal and Replacement This procedure takes approximately 35 minutes to performProcedure Capacitor Removal and REPLACE- Ment Figure F.8 Location and Discharging the Field CapacitorProcedure Field Diode Bridge Removal and Replacement Figure F.8A Field Diode Bridge LocationSTATOR/ROTOR Removal and Replacement This procedure takes approximately 3 hours to performInstructions STATOR/ROTOR Removal and Replacement Troubleshooting & Repair Rotor Removal Procedure Figure F.12 Checking ROTOR-STATOR AIR GAP Engine Output Auxiliary Power Receptacle OUTPUT1Retest After Repair WELDER/GENERATOR OUTPUT1Return to Section TOC Table of Contents Diagrams Section Diagrams Wiring Diagram Power ARCDIAGRAMSG-3 DIAGRAMSG-4 Dimension Print Power ARC Return to Section TOC SVM Error Reporting Form