Lincoln Electric R350 manual Weld and Arc Quality Problems

Page 33

E-6

TROUBLESHOOTING

E-6

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Basic Machine Problems (Continued)

 

Thermal LED is ON

1.

Improper fan operation.

1. Check for proper fan operation.

 

 

 

 

 

 

Fan should run in a low speed

 

 

 

 

 

 

setting when the machine is idle

 

 

 

 

 

 

and in a high speed when the

 

 

 

 

 

 

output is triggered. Check for

 

 

 

 

 

 

material blocking intake or

 

 

 

 

 

 

exhaust louvers, or for excessive

 

 

 

 

 

 

dirt clogging cooling channels in

 

 

 

 

 

 

machine.

 

 

 

 

 

 

 

 

 

 

 

2.

Open thermostat circuit.

2. Check for broken wires, open

 

 

 

 

 

 

connections or faulty thermostats

 

 

 

 

 

 

in the thermostat circuit.

 

 

 

 

 

 

 

 

 

“Real Time Clock” no longer func-

1.

Control PC Board Battery.

1. Replace the battery (Type:

 

 

tioning

 

 

BS2032)

 

 

 

 

 

 

 

 

 

 

Weld and Arc Quality Problems

 

 

 

General degradation of weld perfor-

1.

Wire feed problem.

1. Check for feeding problems. Make

 

 

mance

 

 

sure proper gear ratio has been

 

 

 

 

 

 

selected.

 

 

 

 

 

 

 

 

 

 

 

2.

Cabling problems.

2. Check for bad connections,

 

 

 

 

 

 

excessive loops in cable, etc.

 

 

 

 

 

 

NOTE: The presence of heat in the

 

 

 

 

 

 

external welding circuit indicates

 

 

 

 

 

 

poor connections or undersized

 

 

 

 

 

 

cables.

 

 

 

 

 

 

 

 

 

 

 

3.

Loss of, or improper Shielding

3. Verify gas flow and type are cor-

 

 

 

 

 

Gas.

rect.

 

 

 

 

 

 

 

 

 

 

 

4.

Verify weld mode is correct for

4.Select the correct weld mode for

 

 

 

 

 

process.

the application.

 

 

 

 

 

 

 

 

 

 

 

5.

Machine calibration.

5. The power source may require

 

 

 

 

 

 

calibration. (current, voltage,

 

 

 

 

 

 

WFS).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

POWER WAVE® R350

Image 33
Contents Safety Depends on You Power Wave R350California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a LʼArc Précautions DE SûretéThank You Table of Contents Technical Specifications Power Wave R350 InstallationOperating Temperature Range Model Height Width Depth WeightStorage Temperature Range Process Output Range AmperesEquipment can Cause injury FallingPower Cord Replacement Input Fuse and Supply Wire ConsiderationsInput Connection Input Voltage SelectionGmaw MIG Welding Connection DiagramOutput Cable Guidelines Table A.1 Recommended Work Cable Sizes for ARC WeldingCable Inductance and ITS Effects on Welding Remote Sense Lead SpecificationsTable A.2 WaveWork Voltage Sensing Electrode Voltage SensingIf Sense Leads are not Used Voltage Sensing Considerations for Multiple ARC SystemsFigure A.8 Product specific Installation Instructions Connection Between Power Source and Ethernet NetworksControl Cable Connections Safety Precautions OperationElectric Shock can Kill Product Description Recommended Processes and EquipmentProduct Summary Case Front Controls Design FeaturesNegative Output Terminal Positive Output Terminal Optional VOLTS/AMPS DisplayOptional Devicenet Connector 5 PIN Sealed Mini Style SYNC-TANDEM Connector 4 PIN MS StyleCase Back Controls Arclink Receptacle and Circuit Breaker 2 10 AMPMaking a Weld Common Welding ProceduresNON-SYNERGIC Welding Modes Synergic Welding ModesGtaw TIG Welding Constant Voltage WeldingPulse Welding Figure B.4 Accessories KITS, Options and AccessoriesGeneral Options Routine Maintenance MaintenancePeriodic Maintenance Calibration SpecificationHOW to USE Troubleshooting Guide TroubleshootingTable E.1 Using the Status LED to Troubleshoot System ProblemsMain Control Board Status Light Error Code # IndicationInput Control Board Basic Machine Problems Weld and Arc Quality Problems Troubleshooting Ethernet Diagrams Dimension Print Power Wave R350 Power Wave R350 Precaucion Warnung