Lincoln Electric IM10020 manual Cutting Process, Figure B.3

Page 15

B-5

OPERATION

B-5

 

 

 

5.Air Pressure Gauge and Regulator Knob: Allows regulation and monitoring of the air pressure.

Items 6 thru 9 on the back of the TOMAHAWK™ 625 (See Figure B.3)

6.Fan: Provides machine cooling. When the machine is switched ON, the fan runs continuously.

7.Power Switch: Turns ON / OFF the input power to the machine.

8.Input cable: Connects unit to the input power.

9.Air Inlet: External Air operating mode only. Compressed Air Connection.

WARNING

Clean, dry air must be supplied to the machine. A pressure setting above 110 PSI (7.5 bar) could damage the torch. Failure to observe these pre- cautions could result in excessive operating tem- peratures or damage to the torch.

------------------------------------------------------------------------

CUTTING PROCESS

When preparing to cut, position the machine as close to the work as possible. Make sure to have all materi- als needed to complete the job and have taken all safety precautions. It is important to follow these oper- ating steps each time the machine is used.

FIGURE B.3

7

6

9

8

Turn the machine's ON/OFF POWER SWITCH to the OFF position.

Connect the air supply to the machine.

Turn the main power on and the machine power switch to the ON position.

-The fan will start.

-The pre-charge circuit will operate for 3 seconds, then the green "Power" LED will illuminate.

Attach the work lead clamp to the workpiece before cutting.

Set the output current control knob to maximum position for higher cutting speed and less dross for- mation. Reduce the current, if desired to reduce the kerf (cut) width, heat affected zone, or travel speed as required.

Note: If the circuit breaker trips while cutting at high- er amperages - reduce the cutting amperage on the unit, or provide an input circuit with higher current capacity.

Rotate the output knob into the purge zone to check or set the gas pressure. Pull the pressure regulator cap out and turn it to set the pressure.

-Adjust the gas regulator for 75-80 PSI (0.50-0.55 MPa).

-Turn the output knob out of the purge zone.

-The gas will immediately turn off. The pressure gage may show an increase in pressure after the air turns off but this is normal. Do NOT reset the pressure while the air is NOT flowing.

TOMAHAWK™ 625

Image 15
Contents Tomahawk Safety Depends on YouPLASMA CUTTING or Gouging can be hazardous SafetyElectric and Magnetic Fields Cylinder may explode if damagedPage Sûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Range Voltage InstallationTechnical Specifications -TOMAHAWK CurrentInput Electrical Connections Safety Precautions Electric Shock can KillSelect Proper Location High Frequency Interference ProtectionOutput Connections GAS Input ConnectionsDescription Safety PrecautionsPreheat Temperature for Plasma Cutting OperationUser Responsibility Design Features AdvantagesConsumable Life Cutting CapabilityLimitations Controls and SettingsFigure B.3 Cutting ProcessElectric Shock can Kill TorchProcedure Recommendations Pilot ARC DiscussionTorch Standoff Suggestions for Extra Utility from the Tomahawk 625 System Torch Part Configurations Standard Cutting SetupContact Cutting Setup Gouging Setup Expendable Parts AccessoriesGeneral Options /ACCESSORIES TorchesThermal Protection MaintenanceROUTINE MAINTENANCE PERIODIC MAINTENANCEHOW to USE Troubleshooting Guide TroubleshootingTroubleshooting Tomahawk 625 powers up 1. Turn the output knob to purge Your local Lincoln Authorized Field Service FacilityDry. Remove any scale, rust Symptom Check Enhanced Diagram DiagramsWarnung Keep your head out of fumes