OPERATION |
WELDER OPERATION
DUTY CYCLE
Duty Cycle is the percentage of time the load is being applied in a 10 minute period. For example a 60% duty cycle, represents 6 minutes of load and 4 minutes of no load in a 10 minute period.
ELECTRODE INFORMATION
The BIG RED™ 600 is designed for horizontal, ver- tical up, and overhead welding with all types of DC stick electrodes.
For any electrode the procedures should be kept within the rating of the machine. For information on electrodes and their proper application see (www.lincolnelectric.com) or the appropriate Lincoln publication.
WELDING MODE
Set the Welding mode switch for the desired process, either Stick / Gouging or TIG.
CONSTANT CURRENT STICK WELDING
CAUTION
DO NOT TURN THE “OUTPUT RANGE SELEC- TOR” WHILE WELDING because the current may arc between the contacts and damage the switch.
The “Output Range Selector” provides five overlap- ping current ranges. The “Output Current Adjustment” adjusts the current from minimum to maximum within each range. Open circuit voltage is also controlled by the “Output Current Adjustment” permitting control of the arc characteristics.
A high open circuit voltage setting provides the soft “buttering” arc with best resistance to
For example: to obtain 175 amps and a soft arc, set the “Output Range Selector” to the
When a forceful “digging” arc is required, usually for vertical and overhead welding, use a higher “Output Range Selector” setting and lower open circuit volt- age.
For example: to obtain 175 amps and a forceful arc, set the “Output Range Selector” to the
Some arc instability may be experienced with EXX10 electrodes when trying to operate with long arc techniques at settings at the lower end of the open circuit voltage range.
CAUTION
DO NOT attempt to set the “Current Range Selector” between the five points designated on the nameplate.
ARC GOUGING
Using the “Output Range Selector” and “Output Control Adjustment” set the output to the desired level for the gouging electrode being used see table B.2.
TABLE B.2
Carbon Diameter | Current Range (DC, elec- | |
|
| trode positive) |
|
|
|
| 1/8"(3.2mm) | |
|
|
|
| 5/32"(4.0mm) | |
|
|
|
| 3/16"9(4.8mm) | |
|
|
|
| 1/4"(6.4mm) | |
|
|
|
| 5/16"(8.0mm) | |
|
|
|
| 3/8"(9.5mm) | |
|
|
|
BIG RED™ 600