Lincoln Electric IM847-D manual Accessories, Optional Kits

Page 32

C-1

 

 

ACCESSORIES

 

 

C-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPTIONAL KITS:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Includes: 10k potentiometer,

 

 

 

 

 

 

 

 

 

K2329-1

 

Remote Voltage Control Kit.

 

harness, knob and decal with

 

 

 

 

 

 

 

 

 

 

 

 

 

 

a 0-10 scale and mounting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

hardware.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Includes: Panel and harness

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K2330-1

 

Timer Kit.

 

for adjusting burnback and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

postflow times.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Includes: Wire Reel Stand for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K2328-1

 

Standard Duty Wire Reel Stand.

 

up to 44 lbs (20 kg) spools,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Spindle and mounting hard-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ware.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K2331-1

 

Lift Bail Kit.

 

Includes: Insulated lift bail

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and hardware.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K2332-1

 

Swivel Kit.

 

Includes: Swivel adapter and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(for use with Standard Duty Bench

 

mounting hardware for attach-

 

 

 

 

 

 

 

 

 

 

 

 

Models)

 

ing to a power source lift bale.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Includes: Coaxial weld cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of length "xx". Ends of the

 

 

 

 

 

 

 

 

 

K1796-xx

 

Co-Axial Power Cable.

 

weld cable have lug connec-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tions. Use for Pulse or STT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

welding.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Includes: Twist-Mate to Lug

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2/0 cable 14' (1.2m) long with

 

 

 

 

 

 

 

 

 

K1803-1

 

Work and Feeder Cables Package.

 

Ground Clamp, and Twist-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mate to Lug 2/0 Cable 9'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(2.7m) long.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K1840-xx

 

Weld Power Cable, Twist-Mate to

 

Includes: Twist-Mate to Lug,

 

 

 

 

 

 

 

 

 

 

 

 

Lug.

 

1/0 cable of length "xx".

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Includes: Twist-Mate to Twist-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mate, 1/0 Cable for 25' (7.6m)

 

 

 

 

 

 

 

 

 

K1841-xx

 

Weld Power Cable,

 

cables.

 

 

 

 

 

 

 

 

 

 

 

 

Twist-Mate to Twist-Mate.

 

Includes: Twist-Mate to Twist-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mate, 2/0 Cable for 50'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(15.2m) cables.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Includes: Lug to Lug, 3/0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cable of length "xx" for lengths

 

 

 

 

 

 

 

 

 

K1842-xx

 

Weld Power Cable, Lug to Lug.

 

up to 60' (18.3m). Lug to Lug,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4/0 Cable of length "xx" for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

lengths greater than 60'

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(18.3m).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LF-72

Image 32
Contents LF-72 Wire Feeder Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcTable of Contents Thank YouSection C Section aSection B Section D Section ESection F P-622Installation Amp Rating Duty CycleMounting Safety PrecautionLocation Bench Mount Swivel MountBoom Mount SuspendedElectric Shock can Kill Weld Cable SizesCoaxial Weld Cables Weld Cable ConnectionControl Cable Connections 6INSTALLATIONA-6Analog Control Cable Pin Function Miller Power Source Lincoln Wire FeederAnalog Miller Control Cable Adapter K2335-1 Wire Drive Systems Welding GUN/WIRE Feeder Trigger ConnectorRemote Sense Lead Specifications High Frequency ProtectionWelding GUNS, Torches and ACCES- Sories Figure A.3Procedure for Changing Drive and Idle Roll Sets Wire Drive ConfigurationSet the pressure arm as follows See Figure A.6 Pressure ARM AdjustmentGun Receiver For use With Bushing Wire Reel Loading Spindle PlacementLoading 16 to 44 lb .3 20kg Spools See figure A.8 Loading 30 lb .6 kg Readi-Reels See Figure A.9Weld Wire Routing Figure A.9Shielding GAS Connection Installing Electrode Conduit Kits Figure A.10a For Codes 11209, 11210, 11211 and aboveAluminum Wire Preparations Figure A.12a For Codes 11209, 11210, 11211 and aboveBase Model Bench Model Standard Duty Bench Model Heavy Duty 15’, Magnum Pro Typical System Configurations15, Magnum Safety Precautions OperationCommon Welding Abbreviations Product DescriptionRecommended Processes Required Equipment Front Panel Controls and Connections Figure B.1 DescriptionBurnback and Postflow Timer KIT Cold FEED/GAS Purge SwitchStep Trigger Interlock Switch Remote Voltage Control KITWire Feed Speed Knob Trigger Connector 5-PIN AmphenolGUN Receiver Bushing K1500-2 Trigger InterlockAccessories Optional KitsOptional Kits Accessories Key Maintenance MaintenanceRoutine Maintenance Periodic MaintenanceFor Codes above 11290 use See Figure D.2For Codes below 11289 use 9 thru Troubleshooting HOW to USE Troubleshooting GuideOutput Problems Installed Wiring Diagram LF-72 Feeder 11075, 11076LF-72 Feeder for Codes 11209, 11210, 11211 L12146-1Diagrams Diagrams Dimension Prints Bench Model Bench Model Standard DutyBench Model Heavy Duty Precaucion Warnung