Lincoln Electric IM810 manual Installation

Page 8

A-1

INSTALLATION

A-1

 

 

 

 

TECHNICAL SPECIFICATIONS – Pro-MIG 175

INPUT – SINGLE PHASE ONLY

Standard Voltage/Frequency

230V/60Hz

208V/60Hz

Input Current

20 Amps – Rated Output

22 Amps – Rated Output

Duty Cycle

30% Duty Cycle @ 230V/60Hz

25% Duty Cycle @ 208V/60Hz

Welding Current Range

Rated DC Output: 30 – 175 amps

RATED OUTPUT

Current

130Amps

130Amps

OUTPUT

Maximum Open Circuit Voltage

33V

Volts at Rated Amperes

20V

20V

Wire Speed Range

50-400IPM (1.3-10.2m/min)

RECOMMENDED INPUT CABLE AND FUSE SIZES

 

 

 

 

 

 

 

 

 

 

 

 

Fuse or

 

 

 

 

Output Mode

 

Input Voltage

Breaker Size

Input Amps

Power Cord

 

 

 

 

 

 

 

 

 

 

RATED

 

230V/60Hz

40 Super Lag

20/22

50 Amp, 250V,

 

 

 

 

208V/60Hz

 

 

Three-Prong Plug

 

 

 

 

 

 

 

(NEMA Type 6-50P)

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

 

 

 

Height

 

Width

Depth

Weight

 

 

12.0 in

 

9.75 in

16.5 in

57 Ibs

 

 

305 mm

 

248 mm

419 mm

25.9 kg

 

 

 

 

 

 

 

 

 

Pro-MIG 175

Image 8 Contents
Pro-MIG Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately On-Line Product RegistrationTable of Contents Installation Safety Precautions Identify and Locate ComponentsWork Clamp Installation Select Suitable LocationOutput Connections StackingConnecting Gun Cable to the Pro-MIG GUN InstallationWork Cable Installation Input Connections Figure A.5Volt Input Connection Line Cord ConnectionElectrical Input Connection for Rated Output Saftey Precautions Design Features AdvantagesOperation General DescriptionLimitations Controls and SettingsWelding Capability Wire Loading Friction Brake AdjustmentWelding Operations Sequence of OperationWire Threading Refer to Figure B.4 Over the drive roll 3, and into the outgoingMaking a Weld Cleaning Tip And NozzleProcess Guidelines Overload Protection Changing Machine Over to Feed Other Wire SizesWelding with Gmaw MIG Application Chart Accessories Optional AccessoriesK586-1 Deluxe Adjustable Gas Regulator & Hose Kit K549-1 .035 0.9 mm Innershield Welding KitInnershield Fcaw Conversion Replacement Parts025 .035 0.6 0.9mm wire Routine Maintenance MaintenanceMaintenance Safety Precautions GUN and Cable Maintenance Configuration of Components in Wire Feeding SystemFor Magnum 100L GUN Contact Tip Cable Liner Drive RollComponent Replacement Procedures Changing the Contact TIPLiner trim length Changing LinerGUN Handle Parts Troubleshooting HOW to USE Troubleshooting GuideProblems Possible Symptoms Cause Recommended Course of ActionGAS Flow Problems Welding Problems Pro-MIG 175 Wiring Diagram Page Page Precaucion Warnung