Lincoln Electric Complete Guide to Lincoln Invertec V160-S Operation and DIP Switch Configuration

Page 16

B-4

OPERATION

B-4

 

 

 

DIP SWITCH FUNCTIONS

This section has 8 DIP switch functions of the V160-

S.Read and understand the functions before making any changes because abnormal operation can occur with the wrong settings. The machine must be turned OFF when the DIP Switches are changed.

WARNING

ELECTRIC SHOCK CAN KILL:

Be sure that all installation, opera- tion, maintenance and repair proce- dures are performed only by qualified individuals. Lincoln Electric is not responsible for damages caused by

improper installation, improper care or abnormal operation.

Before opening the machine to make changes to the DIP Switches it must first be turned OFF and disconnected from the input source. Do not open the machine or change the DIP Switches with power applied to the machine. Only Lincoln trained service technicians are authorized to per- form these modifications.

------------------------------------------------------------------------

The DIP switches are numbered from 1 to 8 shown in Figure B.3. Switch 1 is on the bottom and switch 8 is on the top. When a switch is pushed to the right (or to the back of the machine) it is ON; when it is pushed to the left (or to the front of the machine) it is OFF.

The standard production settings for the V160-S are shown with in bold letters ON Table B.1. If a switch setting has bold letters ON, do not make any changes; abnormal operation could occur.

TABLE B.1

 

DIP

V160-S

V160-S

 

Switch

CE

USA

 

 

 

1

ON

ON

 

2

OFF

OFF

 

 

3

OFF

ON

 

 

4

ON

OFF

 

 

5

OFF

OFF

 

 

6

OFF

ON

 

 

7

OFF

OFF

 

 

8

OFF

OFF

 

 

 

 

 

 

DIP Switch 1: Machine Type

This controls the output of the V160-S and some welding waveform functions. It configures the V160-S to automatically turn ON depending on the position of the Welding Mode switch. Refer to DIP Switch 6 for more information.

DIP Switch 2 thru 5 non-functional for the V160-S.

FIGURE B.3

Front of machine

DIP

Switch 8

DIP

Switch 1

V160-S

Image 16
Contents Invertec V160-S Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a LʼArcThank You Table of Contents Installation Technical Specification V160-SOperating Temperature Range Storage Temperature RangeSafety Precautions Input ConnectionsSelect Suitable Location Ground ConnectionArfu AUTO-RESTORE Fuse 230V Input115V Input Attachment PlugOutput and GAS Connection for TIG Welding Figure A.1 Output Connection for Stick Welding Figure A.2Quick Disconnect Plug for Stick ELEC- Trode Cable Remote Control ConnectionOutput Connection for TIG Welding Safety Instructions OperationGeneral Description Welding CapabilityPower Switch Fan V160-S Controls and Settings See Figure B.2Rear Control Panel Mode Switch Power LEDArc Control Thermal LEDDIP Switch Functions DIP Switch 1 Machine TypeDIP Switch 2 thru 5 non-functional for the V160-S Electric Shock can KillDIP Switch 6 European/USA Machine Configuration DIP Switch 1 = onDIP Switch 7 thru 8 non-functional for the V160-S START/CRATER Current AdjustmentAccessories Optional AccessoriesCompatible Equipment Cable PlugsMaintenance Safety PrecautionsInput Filter Capacitor Discharge Procedure Routine MaintenanceTroubleshooting HOW to USE Troubleshooting GuideTroubleshooting Troubleshooting Troubleshooting Diagrams Wiring Diagram CodeV160-S Wiring Diagram Wiring Diagram CodeV160-S Precaucion Warnung