Lincoln Electric V160-S manual DIP Switch 6 European/USA Machine Configuration, DIP Switch 1 = on

Page 17

B-5

OPERATION

B-5

 

 

 

DIP Switch 6: European/USA Machine

Configuration

This configures several functions of the V160-S as required by the European and USA markets. For the European market it is OFF and for the USA market it is ON.

Specifically, this configures the operation of the TIG slope timers, remote control, and trigger. However, this configuration also depends on the position of DIP Switch 1 which selects the machine type. This setting can be changed but only if the following functions are clearly understood.

(DIP Switch 1 = ON)

In TIG welding mode, the following conditions can exist.

No TIG slopes are available. If slopes are needed a foot pedal remote control can be used.

No remote control connected. With no remote con- trol connected, the output is ON and a trigger is not needed. Simple Lift TIG welding is possible.

Remote control connected. With a remote control connected, the output is OFF and a trigger is need- ed. Simple Lift-TIG welding is possible using a 2- step trigger sequence.

DIP Switch 7 thru 8 non-functional for the V160-S.

START/CRATER CURRENT ADJUSTMENT

It is not possible to change the start/crater current of a "S" type machine. The values set from the factory are:

European Machines: 20% (160A welding current = 32A start/crater current)

USA Machines: 10% (160A welding current = 16A start/crater current)

V160-S

Image 17
Contents Invertec V160-S California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a LʼArc Précautions DE SûretéThank You Table of Contents Technical Specification V160-S InstallationOperating Temperature Range Storage Temperature RangeInput Connections Safety PrecautionsSelect Suitable Location Ground Connection230V Input Arfu AUTO-RESTORE Fuse115V Input Attachment PlugOutput Connection for Stick Welding Figure A.2 Output and GAS Connection for TIG Welding Figure A.1Output Connection for TIG Welding Remote Control ConnectionQuick Disconnect Plug for Stick ELEC- Trode Cable Operation Safety InstructionsGeneral Description Welding CapabilityRear Control Panel Controls and Settings See Figure B.2Power Switch Fan V160-S Power LED Mode SwitchArc Control Thermal LEDDIP Switch 1 Machine Type DIP Switch FunctionsDIP Switch 2 thru 5 non-functional for the V160-S Electric Shock can KillDIP Switch 1 = on DIP Switch 6 European/USA Machine ConfigurationDIP Switch 7 thru 8 non-functional for the V160-S START/CRATER Current AdjustmentOptional Accessories AccessoriesCompatible Equipment Cable PlugsSafety Precautions MaintenanceInput Filter Capacitor Discharge Procedure Routine MaintenanceHOW to USE Troubleshooting Guide TroubleshootingTroubleshooting Troubleshooting Troubleshooting Wiring Diagram Code DiagramsWiring Diagram Code V160-S Wiring DiagramV160-S Precaucion Warnung