Lincoln Electric Installation, Technical Specification V160-S, Operating Temperature Range

Page 8

 

A-1

 

 

 

 

 

 

 

 

INSTALLATION

 

 

 

 

 

 

A-1

 

TECHNICAL SPECIFICATION V160-S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT - SINGLE PHASE ONLY

 

 

 

 

Input Voltages / 50 /60 Hz.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. Input Current at rated Output

 

 

 

 

115 V (20 A Plug and branch)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20 A

 

 

 

 

 

 

 

115 V (30 A branch)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25 A

 

 

 

 

 

 

230 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34 A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED

OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output Amps

 

 

 

Output Volts

 

 

 

 

 

 

Input Circuit

 

 

 

 

Duty Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60 (Stick)

 

 

 

22.4

 

 

 

 

 

 

115V (20A Plug and Branch)

 

 

 

 

 

 

 

 

 

 

 

 

90 (TIG)

 

 

 

13.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80 (Stick)

 

 

 

23.2

 

 

 

 

 

 

115V (30A Branch)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

110 (TIG)

 

 

 

14.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

35%

 

 

 

 

160 (Stick)

 

 

 

26.4

 

 

 

 

 

 

230V (30A Branch)

 

 

 

 

 

 

 

 

 

 

160 (TIG)

 

 

 

16.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100%

 

 

 

 

130 (Stick)

 

 

 

25.2

 

 

 

 

 

 

230V (30A Branch)

 

 

 

 

 

 

 

 

 

 

130 (TIG)

 

 

 

15.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

Output Current Range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Open Circuit Voltage

 

 

 

 

 

 

Type of Output

 

 

 

5-160 Amps

 

 

 

 

 

 

 

48 Volts

Max.

 

 

 

 

 

 

DC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECOMMENDED

 

 

INPUT WIRE AND FUSE SIZES FOR

MAXIMUM RATED OUTPUT

 

 

 

INPUT VOLTAGE /

 

TYPE S, SO ST, STO, OR EXTRA

 

 

 

MAXIMUM TIME-DELAY CIRCUIT

 

 

 

FREQUENCY (HZ)

 

HARD USAGE INPUT CORD AWG

 

BREAKER OR FUSE SIZE (AMPS)

 

 

 

 

230/50/60

 

 

 

 

 

 

 

#12

 

 

 

 

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

 

 

 

 

 

 

 

 

 

 

 

 

Height

 

Width

 

 

 

Depth

 

Weight

 

 

12.6 in.

 

7.9 in.

 

 

 

16.9 in.

 

Approx. 24.2lbs.

 

 

320 mm

 

200 mm

 

 

 

430 mm

 

11 kgs.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE RANGES

OPERATING TEMPERATURE RANGE

-20°C to +40°C

STORAGE TEMPERATURE RANGE

-50°C to +85°C

V160-S

Image 8
Contents Invertec V160-S Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a LʼArcThank You Table of Contents Installation Technical Specification V160-SOperating Temperature Range Storage Temperature RangeSafety Precautions Input ConnectionsSelect Suitable Location Ground ConnectionArfu AUTO-RESTORE Fuse 230V Input115V Input Attachment PlugOutput and GAS Connection for TIG Welding Figure A.1 Output Connection for Stick Welding Figure A.2Output Connection for TIG Welding Remote Control ConnectionQuick Disconnect Plug for Stick ELEC- Trode Cable Safety Instructions OperationGeneral Description Welding CapabilityRear Control Panel Controls and Settings See Figure B.2Power Switch Fan V160-S Mode Switch Power LEDArc Control Thermal LEDDIP Switch Functions DIP Switch 1 Machine TypeDIP Switch 2 thru 5 non-functional for the V160-S Electric Shock can KillDIP Switch 6 European/USA Machine Configuration DIP Switch 1 = onDIP Switch 7 thru 8 non-functional for the V160-S START/CRATER Current AdjustmentAccessories Optional AccessoriesCompatible Equipment Cable PlugsMaintenance Safety PrecautionsInput Filter Capacitor Discharge Procedure Routine MaintenanceTroubleshooting HOW to USE Troubleshooting GuideTroubleshooting Troubleshooting Troubleshooting Diagrams Wiring Diagram CodeV160-S Wiring Diagram Wiring Diagram CodeV160-S Precaucion Warnung