Lincoln Electric V160-S Mode Switch, Arc Control, Power LED, Thermal LED, Remote LED, Output LED

Page 15

B-3

OPERATION

B-3

 

 

 

7.Remote LED: This indicator will turn on when a remote control is connected to the machine via the remote control connector. Using a remote control will change the function of the output current con- trol, refer to the output current control section below.

8.Output LED: This indicator turns on when the out- put of the machine is on.

In stick welding mode, the output of the machine is automatically turned ON.

In Lift TIG welding mode without a remote control, the output of the machine is automatically turned ON. In this condition a triggering device is not needed.

In Lift TIG welding mode with a remote control, the output of the machine is turned ON and OFF by the remote device (i.e. hand or foot amptrol) connected to the remote connector on the front of the machine. Output must be triggered ON (output LED lit) to enable Lift TIG starting. After machine output is triggered ON, the arc must be started within 6.5 seconds or output will turn OFF and trigger sequence must be restarted. (Note: Any remote control device with trigger-only circuit, such as the K814 Arc Start Switch, will not be sensed by the V160-S remote control connection, and therefore will not allow control of the output).

9.Output Current Control: This controls the output or welding current of the machine.

The function of this control knob is changed if a remote control is connected. If the Remote LED is ON, this indicates that a remote control is connect- ed and the function of the output current control will be:

Stick Welding Mode: The remote control will adjust the output current of the machine from 5 to 160A. The output current control knob on the display panel is not used.

TIG Welding Modes: The maximum output current of the machine is set by the output current control knob. The remote control then adjusts the output current from the minimum output (5A) to the value set by the output current control knob. For example, if the output current control knob on the machine is set to 100A then the remote control will adjust the output current from a minimum of 5A to a maximum of 100A.

10.“Twist-Mate” Connection (Negative)

11.Remote Control Connector

12.“Twist-Mate” Connection (Positive)

FIGURE B.2

57

6

8

 

 

3. Mode Switch

3

 

4. Arc Control

 

9

5. Power LED

 

 

6. Thermal LED

4

 

7 Remote LED

 

 

8. Output LED

 

 

9. Output Current Control

 

 

10. Electrode Connection (Negative)

 

 

11. Remote Control Connector

 

 

12. Electrode Connection (Positive)

10

12

 

11

 

 

V160-S

Image 15
Contents Invertec V160-S California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a LʼArc Précautions DE SûretéThank You Table of Contents Storage Temperature Range InstallationTechnical Specification V160-S Operating Temperature RangeGround Connection Safety PrecautionsInput Connections Select Suitable LocationAttachment Plug Arfu AUTO-RESTORE Fuse230V Input 115V InputOutput Connection for Stick Welding Figure A.2 Output and GAS Connection for TIG Welding Figure A.1Remote Control Connection Quick Disconnect Plug for Stick ELEC- Trode CableOutput Connection for TIG Welding Welding Capability Safety InstructionsOperation General DescriptionControls and Settings See Figure B.2 Power Switch Fan V160-SRear Control Panel Thermal LED Mode SwitchPower LED Arc ControlElectric Shock can Kill DIP Switch FunctionsDIP Switch 1 Machine Type DIP Switch 2 thru 5 non-functional for the V160-SSTART/CRATER Current Adjustment DIP Switch 6 European/USA Machine ConfigurationDIP Switch 1 = on DIP Switch 7 thru 8 non-functional for the V160-SCable Plugs AccessoriesOptional Accessories Compatible EquipmentRoutine Maintenance MaintenanceSafety Precautions Input Filter Capacitor Discharge ProcedureHOW to USE Troubleshooting Guide TroubleshootingTroubleshooting Troubleshooting Troubleshooting Wiring Diagram Code DiagramsWiring Diagram Code V160-S Wiring DiagramV160-S Precaucion Warnung