Lincoln Electric V160-S manual Quick Disconnect Plug for Stick ELEC- Trode Cable

Page 12

A-5

INSTALLATION

A-5

 

 

 

QUICK DISCONNECT PLUG (FOR STICK ELEC- TRODE CABLE)

A quick disconnect system is used for the welding cable connections. The stick electrode cable will need to have a plug attached.

1.Cut off welding cable lug, if present.

2.Remove .75 in. (19mm) of welding cable insulation.

3.Slide rubber boot onto cable end. The boot end may be trimmed to match the cable diameter. Use soap or other nonpetroleum-based lubricant to help slide the boot over the cable, if needed.

BOOT

WELDING CABLE

.75 in.

19 mm

TRIM, IF REQ'D

TO FIT OVER CABLE

4. Cut 45-50% of the copper strands back 1/4” (6 mm).

WELDING CABLE

.25 in. 6 mm

5.Fold copper strands over cut strands and insert into ferrule.

COPPER FERRULE

WELDING CABLE

.50 in. max 12 mm max.

6. Slide the copper ferrule into the brass plug.

SET SCREW

BRASS PLUG

COPPER TUBE

7.Tighten set screw to collapse copper tube. Screw must apply pressure against welding cable. The top of the set screw will be well below the surface of the brass plug after tightening.

OUTPUT CONNECTION FOR TIG WELDING

A one piece Gas Valve Tig Torch is recommended for use with the V160-S. A K960-1 Tig Torch adapter is required. See accessories section.

REMOTE CONTROL CONNECTION

A remote control receptacle is provided on the lower center case front of the welder for connecting a remote control to the machine. The V160-S will auto- matically sense if a remote control connection is made. In Lift TIG mode (GTAW), WITHOUT a remote control device connected to the V160-S, the output will come on automatically. WITH a remote control device connected to the unit, the output will need to be triggered, i.e. a Foot Amptrol. Refer to the Optional Accessories section of this manual for available remote controls.

The following items can be connected to the 6 pin socket on the front panel:

Remote control potentiometer (K857) for Stick welding.

Remote Foot Amptrol (K870), Hand Amptrol (K963-3).

V160-S

Image 12
Contents Invertec V160-S Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a LʼArcThank You Table of Contents Installation Technical Specification V160-SOperating Temperature Range Storage Temperature RangeSafety Precautions Input ConnectionsSelect Suitable Location Ground ConnectionArfu AUTO-RESTORE Fuse 230V Input115V Input Attachment PlugOutput and GAS Connection for TIG Welding Figure A.1 Output Connection for Stick Welding Figure A.2Remote Control Connection Quick Disconnect Plug for Stick ELEC- Trode CableOutput Connection for TIG Welding Safety Instructions OperationGeneral Description Welding CapabilityControls and Settings See Figure B.2 Power Switch Fan V160-SRear Control Panel Mode Switch Power LEDArc Control Thermal LEDDIP Switch Functions DIP Switch 1 Machine TypeDIP Switch 2 thru 5 non-functional for the V160-S Electric Shock can KillDIP Switch 6 European/USA Machine Configuration DIP Switch 1 = onDIP Switch 7 thru 8 non-functional for the V160-S START/CRATER Current AdjustmentAccessories Optional AccessoriesCompatible Equipment Cable PlugsMaintenance Safety PrecautionsInput Filter Capacitor Discharge Procedure Routine MaintenanceTroubleshooting HOW to USE Troubleshooting GuideTroubleshooting Troubleshooting Troubleshooting Diagrams Wiring Diagram CodeV160-S Wiring Diagram Wiring Diagram CodeV160-S Precaucion Warnung