Lincoln Electric SP-250 Fuse and Wire Sizes, Input Power Connections Ground Connections

Page 10

A-3

INSTALLATION

A-3

 

 

Return to Section TOC

Section TOC

FUSE AND WIRE SIZES

Protect the input circuit with the super lag fuses or delay type circuit breakers listed on the Specifications page of this manual for the machine being used. The tripping action of delay type circuit breakers decreases as the magnitude of the current increases. They are also called inverse time or thermal/magnetic circuit breakers.

DO NOT use fuses or circuit breakers with a lower amp rating than recommended. This can result in "nui- sance" tripping caused by inrush current even when machine is not being used for welding at high output currents.

Use input and grounding wire sizes that meet local electrical codes or see the Specifications page in this manual.

proper grounding of the welder frame when the welder plug is inserted into the receptacle.

4.Use proper wire sizes. See the Specification table for proper wire sizes. For cable lengths over 100 feet, larger copper wires should be used.

Return to

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

INPUT POWER CONNECTIONS AND

GROUND CONNECTIONS

FIGURE A.2. - Ground Connections.

 

Have a qualified electrician connect the receptacle or cable to the input power lines and the system ground according to the U.S. National Electrical Code and any applicable local codes.

1.Follow the Input Supply Connection Diagram on the inside of the Reconnect Panel Access Door.

2.Use a single-phase line or one phase of a three- phase line.

For the 208V/230V/ 60 HZ model SP 250 shipped with a 10 ft. input cord and plug connected to the welder, mount the matching receptacle supplied with the machine.

1.Mount the receptacle in a suitable location using the screws provided.

2.Locate the receptacle within reach of the 10 ft. input cord attached to the welder.

3.Mount the receptacle with the grounding terminal at the top. This allows the power cable to hang down without bending. See Figure A.2.

a.The center terminal in the receptacle is for the grounding connection.

b.Fuse the two hot lines of the receptacle with super lag type fuses as shown in Figure A.2. A green wire in the input cord connects this ter- minal to the frame of the welder. This ensures

IDEALARC SP-250

Image 10
Contents Safety Depends on You Idealarc SP-250ARC Welding can be hazardous Idealarc SP-250Cylinder may explode if damaged Electric and MAG- Netic Fields IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcTable of Contents Installation Height Depth Weight GUNStorage Operating Input Connections Safety PrecautionsSelect Proper Location StackingFuse and Wire Sizes Input Power Connections Ground ConnectionsConnect Shielding GAS Figure A.3 Ground Connection For 230/460/575 Volt ModelsReconnect Procedure SideReturn to Section TOC Connect Output Components GUN Liner & Contact TIP InstallationInstall the Work Clamp Output Polarity ConnectionGUN & Cable Installation Figure A.9 European Style ConnectorOperation General Description Safety InstructionsAdditional Safety Precautions Electric Shock can killControls System includes the following featuresOperational Recommended ProcessesWire Feeder Features Design FeaturesUnit Features Power Source FeaturesLimitations Machine CapabilityDuty Amps Volts Cycle Controls and Settings Figure B.1 SP-250 Control Panel KeysArrow KEY Operation When Used with Process WIRE/GAS KEYArrow KEY Operation When Used with Auto KEY Arrow KEY Operation When Used with Manual KEYLeft arrow keys Do not function Arrow KEY Operation When Used with Spot KEYArrow KEY Operation When Used with Stitch KEY Right arrow keys Do not functionFigure B.5 Using the Toggle Function Step Trigger Interlock KeysMaking a Weld in Auto Mode RUN-IN ModeChanging RUN-IN Mode Codes 10001 and Above Operating StepsMaking a Spot Weld in Auto Mode Using the 4-STEP Interlock Function in Auto ModeTo make an arc spot plug weld Making a Stitch Weld in Auto Mode Using the GUN Thumb Switch Magnum SP-250 onlyUsing the Wire Drive Roll Using the GUN Trigger SwitchLoading the Wire Reel To mount 10 to 30 lb. spools 8 and 12 diameterSetting Idle Roll Pressure Feeding ElectrodeAccessories Spool GUN Adapter KIT Installation Options / AccessoriesSpool GUN Module Board Installation Figure C.2 Spool Gun Module Board Installation Installation Spool GUN Connection BOXSpool GUN Connection Figure C.5 Spool Gun ConnectSpool GUN Installation to OLD K531 KIT Figure C.6 Spool Gun ConnectionMaintenance Maintenance Routine and PeriodicControl Board Choke Fan Assembly Main Transformer Theory of Operation Input Line Voltage and Main Trans Power Supply OperationFormer Output Rectification and Feed Back ControlConstant Voltage Output Figure E.4 Constant Voltage OutputWire Drive Motor and Feedback Figure E.5 Wire Drive Motor and FeedbackThermal Protection SCR Operation Figure E.6 SCR OperationTroubleshooting & Repair HOW to USE Troubleshooting Guide Recommended Course of ActionPC Board Troubleshooting Procedures Board can be dam- aged by static electricityOutput Problems Warn Troubleshooting & Repair Function Problems Troubleshooting & Repair Wire Feeding Problems Toxic. Avoid contact with any Liquid elecTrolyte in these capacitors is Portion of your bodyTroubleshooting & Repair Explanation of Prompting and Error Messages On Screen Error Message Message ExplanationOn Screen Error Message Explanation of Prompting and Error Messages CONT’DXxxx Current Overload Reduce Output Press ANY KEY to Stop Message Test Description Main Transformer TestMaterials Needed Main Transformer Test Test Procedure Lead Plug Location From Expected Lead Voltage#206 4J6 #208 16J6 #209 7J6 G1992 Code 9402 only Troubleshooting & Repair Static SCR Rectifier Assembly Test Leads Figure F.4 SCR 1 Test Points Active SCR Rectifier Assembly Test Leads Figure F.7 SCR Tester Circuit and SCR connections SP-250 Keypad Resistance Test 25F-25Figure F.8A Plug J2 Location on G2252 PC Control Board Figure F.9 Plug J2 Test Points27F-27 Test Points KEY Pressed Maximum AllowableTable F.1 SP-250 Keypad Resistance Tests Wire Drive Motor and Tachometer Feedback Test Wire Drive Motor and Tachometer Feedback Test Test Procedure Figure F.10A Plug J5 Location on G2252 PC Control Board#206B 4J6 #515B 1J6 #555 2J6 #541 6J6 #539 3J6 Pull the gun triggerTest for Supply Voltage to Tachometer Test for Feedback Voltage to the Control BoardScope Settings Normal Open Circuit Voltage WaveformMachine Loaded to 250 Amps AT 26 VDC Scope Settings Typical Output Voltage Waveform Machine LoadedMachine Loaded to 220 Amps AT 22 VDC Scope Settings Troubleshooting & Repair Typical SCR Gate Voltage Waveform Control PC Board Removal and Replacement Removal and Replacement Procedure Materials NeededTroubleshooting & Repair Keypad Removal and Replacement Keypad Removal and Replacement Procedure Wire Drive Assembly Removal and Replacement Wire Drive Assembly Removal and Replacement Procedure Figure F.13 Wire Drive Assembly RemovalSCR Output Rectifier Removal 43F-43Figure F.14 Heat Sink lead discon- nection Capacitor Bank Removal and Replacement Capacitor Bank Removal and Replacement Procedure Main Transformer Removal and Replacement Power Switch FAN Motor and FAN Removal and Replacement FAN Motor and FAN Removal and Replacement Procedure Figure F.18 Fan Motor and Fan Removal ComponentsTroubleshooting & Repair Input Volts/Hertz Wire Speed RangeOpen Circuit Voltage 230/60 375Table of Contents Electrical Diagrams G1992 Control PC Board Identification X9 . . . . . .IC-CMOS,UNDERVOLT-SENSING,RESET,MCU Idealarc SP-250 Electrical Diagrams G2252 Control PC Board TOC OCI2,OCI3 Optocoupler Triac Driver Idealarc SP-250 Electrical Diagrams Wiring Diagram for Code 9546 SP-250 230/460/575V Wiring DiagramWiring Diagram for Code 9723 Thumb SwitchImproper Lincoln Electric. This information