TYPICAL SCR GATE VOLTAGE WAVEFORM
SCOPE SETTINGS
| This is a typical SCR gate pulse voltage | 
 | 
 | 
| waveform. The machine was in an open cir- | Volts/Div | . .2 V/Div. | 
| cuit condition (no load) and operating prop- | 
 | 
 | 
| erly. Note that each vertical division repre- | Horizontal Sweep | .5 ms/Div. | 
| sents 2 volts and each horizontal division | 
 | 
 | 
| represents 5 milliseconds in time. | Coupling | . . . . .DC. | 
| Note: Scope probes connected at Plug J3 | Trigger | . .Internal. | 
| on the control board. The (+) probe to lead | 
 | 
 | 
| G2, and the  | 
 | 
 | 
| 
 | 
 | 
 |