TROUBLESHOOTING & REPAIR | ||||
|
|
| ||
| EXPLANATION OF PROMPTING AND ERROR MESSAGES |
| ||
ON SCREEN ERROR MESSAGE | MESSAGE EXPLANATION |
| ||
PROCESS MUST |
| Reminder that in Auto mode the process entered with the Process key must | ||
MATCH WIRE & GAS |
| match the process installed in the machine . |
| |
|
|
|
| |
ONLY SET UP FOR |
| Unit is only programmed for .035” (0.9mm) diameter in stainless steel wire. | ||
.035 STAINLESS |
| Other wire diameters can be accommodated by using the Manual mode. | ||
|
|
|
| |
ONLY ARGON USED |
| Unit is programmed to use only argon gas with aluminum electrodes. Other | ||
WITH ALUMINUM |
| gases can be accommodated by using the manual mode. |
| |
|
|
|
| |
ONLY SET UP FOR |
| Unit is only programmed for .045” (1.1mm) diameter in Outershield® elec- | ||
. 045 OUTERSHIELD |
| trode wire. Other wire diameters within the | ||
|
|
| modated by using the Manual mode. |
|
|
|
|
| |
NO GAS REQUIRED |
| Innershield® electrode wire does not require a shielding gas. In the Auto | ||
WITH INNERSHIELD |
| mode, the | ||
|
|
| when the trigger is closed. |
|
|
|
|
| |
MEMORY 1 NOW |
| Verifies that the setup was saved to memory number 1. The actual memo- | ||
CONTAINS SETUP |
| ry number is determined by the memory number key that was pressed fol- | ||
|
|
| lowing Save. |
|
|
|
|
| |
MEMORY 2 |
| An attempt was made to recall a setup from a memory that does not con- | ||
IS EMPTY |
| tain one. The actual memory number is determined by the memory num- | ||
|
|
| ber key that was just pressed. |
|
|
|
|
| |
MEMORY 4 DOESN’T |
| An attempt was made to enter Toggle mode and the process of the Auto | ||
MATCH WIRE & GAS |
| setup in memory 4 does not match the process in the machine. Press | ||
|
|
| memory 4 to find out what process is required. The memory number indi- | |
|
|
| cates which memory, 4 or 5, does not match. |
|
|
|
|
| |
REQ'S: STAINLESS |
| An attempt was made to recall from memory an Auto setup whose process | ||
WIRE .035 Ar/O2 |
| does not match the process in the machine. This message indicates the | ||
|
|
| process required and alternates with the second message until the Process | |
PRESS PROCESS |
| key is pressed. |
| |
|
|
| ||
WHEN INSTALLED |
|
|
| |
|
|
|
|
|