Return to Master TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
| TROUBLESHOOTING & REPAIR | ||
| 
 | 
 | 
ABNORMAL OPEN CIRCUIT VOLTAGE
OUTPUT CAPACITOR BANK NOT FUNCTIONING
SCOPE SETTINGS
| This is NOT the typical DC output voltage | 
 | 
 | 
| waveform. The output capacitors are not | Volts/Div | .20 V/Div. | 
| functioning. Note the lack of “filtering” in the | 
 | 
 | 
| output waveform. The output capacitor | Horizontal Sweep | .5 ms/Div. | 
| bank was disconnected. Each vertical divi- | 
 | 
 | 
| sion represents 20 volts and each horizontal | Coupling | . . . . .DC. | 
| division represents 5 milliseconds in time. | 
 | 
 | 
| Note: Scope probes connected at machine | Trigger | . .Internal. | 
| 
 | 
 | |
| output terminals: (+) probe to electrode,  | 
 | 
 | 
| probe to work. | 
 | 
 | 
| 
 | 
 | 
 |