TROUBLESHOOTING & REPAIR | ||
|
|
TYPICAL OUTPUT VOLTAGE WAVEFORM - MACHINE LOADED
MACHINE LOADED TO 250 AMPS AT 26 VDC
SCOPE SETTINGS
This is a typical DC output voltage wave- |
|
|
form generated from a properly operating | Volts/Div | .20 V/Div. |
machine. Note that each vertical division |
|
|
represents 20 volts and that each horizontal | Horizontal Sweep | .5 ms/Div. |
division represents 5 milliseconds in time. |
|
|
The machine was loaded with a resistance | Coupling | . . . . .DC. |
grid bank. |
|
|
Note: Scope probes connected at machine | Trigger | . .Internal. |
|
| |
output terminals: (+) probe to electrode, |
|
|
probe to work. |
|
|
|
|
|