Lincoln Electric manual Differences between Fema 353 and AWS D1.8

Page 10

10

D1.8 Seismic Supplement Welding Manual

Differences between FEMA 353 and AWS D1.8

As was previously mentioned, much of D1.8 was based upon recommendations contained within FEMA 353. However, differences between the two documents exist. In many cases, FEMA 353 recommendations are not contained in D1.8, but rather reside in the applicable AISC specification. In some situations, the AWS consensus committee made deliberate decisions to approach the issue in a different manner.

Contained below is a partial listing of some of the significant differences:

The complicated and complex “weld categories” as contained in FEMA 353 have been replaced with the three broader and simpler categories as outlined previously in Table 1.

Details of the WPS Heat Input Envelope Testing have been modified. In D1.8, the root pass can be made in a single pass (versus a split pass, as required in FEMA 353), and the position of welding is no longer an essential variable for this test. See D1.8, Annex A.

The Supplemental Welder Qualification test was expanded to include a testing procedure to address welder qualification when steel backing is not used, including where copper or ceramic backing is used, as well as when open root joints are used. See D1.8, Annex D.

Testing of the Supplemental Welder Qualification for Restricted Access Welding may be accomplished by either radiographic testing (RT), ultrasonic testing (UT) or by mechanical testing (FEMA 353 permitted only mechanical testing or RT). Additionally, the typographical error as contained in FEMA 353 that called for 3/4 in. bend tests has been corrected in D1.8 to call for the intended 3/8 in. thick bend specimens. See D1.8, Annex D.

D1.8 contains more definitive alternatives to lot tested filler metals. See D1.8, clause 6.3.8.

D1.8 specifically exempts the high/low heat envelope testing for the welding consumables when SMAW is used with specific filler metals, and when GMAW is performed with solid electrodes. See D1.8, clause 6.3.5.

D1.8 has extended the standard exposure period for FCAW electrodes from 24 to 72 hours. See D1.8, clause 6.4.3.

A variety of other changes have been made, and a careful review of the two documents must be made if the user is interested in a comprehensive comparison.

Differences between AWS D1.8/D1.8M:2005 and AWS D1.8/D1.8M: 2009

The second edition of the AWS D1.8/D1.8M, Structural Welding Code – Seismic Supplement features editorial and technical revisions from the previous edition. These revisions are primarily refinements or clarifications of information presented in the 2005 edition.

www.lincolnelectric.com

Image 10
Contents D1.8 Seismic Supplement Welding Manual Table of Contents IntroductionDocument Updates Customer Assistance PolicyBackground D1.8 Seismic Supplement Welding Manual AWS D1.8 and Aisc Specifications SpecificationsAWS D1.8 and Other Specifications Purpose and Use of This ManualAWS D1.8 and Contract Documents AWS D1.8 and Other AWS StandardsAWS D1.8 and Fema Overview of D1.8 ContentNew Terminology See D1.8, clause Three Kinds of WeldsDifferences between Fema 353 and AWS D1.8 Differences between AWS D1.8/D1.8M2005 and AWS D1.8/D1.8MUser’s Guide to AWS D1.8 EngineersFabricators and Erectors Structural DetailersWelder Qualification D1.8 Seismic Supplement Welding Manual Welding Procedure Specifications WPSs Filler Metals GeneralFiller Metals All D1.8 Welds Filler Metals Demand Critical WeldsSee D1.8, clause Techniques Regarding Filler Metals InspectorsRegarding Welder Qualification Regarding Production WeldingRegarding Structural Details Regarding the Protected ZoneLincoln Electric Products D1.8 Seismic Supplement Welding Manual Exposure Testing Heat Input Limits for Demand Critical WeldsHeat Input Limits for Demand Critical Welds cont’d Appendices Additional Certificates Available Online Smaw and Gmaw Certificates of ConformanceMetal-Cored Wire Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Appendix B Intermix Testing D1.8 Seismic Supplement Welding Manual Appendix C Alternative To Production Lot Testing D1.8 Seismic Supplement Welding Manual D1.8 Seismic Supplement Welding Manual D1.8 Seismic Supplement Welding Manual District Sales Offices Automation Division