Lincoln Electric D1.8 manual Regarding Structural Details, Regarding the Protected Zone

Page 19

D1.8 Seismic Supplement Welding Manual

19

Regarding Structural Details

Ensure that weld access holes are properly prepared. See D1.8, clause 6.9.

Ensure that weld tabs and backing have been removed, when required. See D1.8, clause 6.7, 6.10.

Regarding the Protected Zone

Ensure that no unauthorized welds or attachments have been added. See D1.8, clause 6.15. Ensure that no unacceptable notches or gouges are in the protected zone. See D1.8, clause 6.15.

Ensure that repairs in the protected zone are properly made and inspected, as necessary. See D1.8, clause 6.15.

References

1.Federal Emergency Management Agency, July 2000, Recommended Specifications and Quality Assurance Guidelines for Steel Moment - Frame Construction for Seismic Applications (FEMA 353),

FEMA, Washington, D.C.

2.American Welding Society, 2005, Structural Welding Code-Seismic Supplement (AWS D1.8/D1.8M:2009), AWS, Miami, FL.

3.American Institute of Steel Construction, 2005, Specifications for Structural Steel Buildings (AISC 360-05),AISC, Chicago, IL.

4.American Institute of Steel Construction, 2005, Seismic Provisions for Structural Steel Buildings (AISC 341-05),AISC, Chicago, IL.

5.American Institute of Steel Construction, 2005, Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications (AISC 358-05),AISC, Chicago, IL.

6.American Welding Society, 2010, Structural Welding Code-Steel (AWS D1.1/D1.1M:2010), AWS, Miami, FL.

7.American Welding Society, 1999, Structural Welding Code-Stainless Steel (AWS D1.6/D1.6M:1999), AWS, Miami, FL.

8.American Welding Society, 2005, Specification for Carbon Steel Electrodes for Flux Cored Arc Welding (AWS A5.20/A5.20M:2005), AWS, Miami, FL.

References

Consumable AWS Certificates:

http://www.lincolnelectric.com/products/certificates/

Safety References

Material Safety Data Sheets (MSDS):

http://www.lincolnelectric.com/product/msds/

ANSI Z49.1:

http://www.lincolnelectric.com/community/safety/

E205 Safety Booklet, and other Arc Welding Safety Materials: http://www.lincolnelectric.com/community/safety/

Safe Practices Article: http://www.lincolnelectric.com/knowledge/articles/content/lenstaybl.asp

Note

A FEMA 353 Welding Manual was prepared and is still available for download at http://content.lincolnelectric.com/pdfs/products/literature/c160.pdf. Also, FEMA 353 is available for download at http://www.fema.gov/plan/prevent/earthquake/pdf/fema-353.pdf.

www.lincolnelectric.com

Image 19
Contents D1.8 Seismic Supplement Welding Manual Introduction Table of ContentsCustomer Assistance Policy Document UpdatesBackground D1.8 Seismic Supplement Welding Manual Purpose and Use of This Manual SpecificationsAWS D1.8 and Other Specifications AWS D1.8 and Aisc SpecificationsAWS D1.8 and Contract Documents AWS D1.8 and Other AWS StandardsAWS D1.8 and Fema Overview of D1.8 ContentNew Terminology Three Kinds of Welds See D1.8, clauseDifferences between AWS D1.8/D1.8M2005 and AWS D1.8/D1.8M Differences between Fema 353 and AWS D1.8Engineers User’s Guide to AWS D1.8Fabricators and Erectors Structural DetailersWelder Qualification D1.8 Seismic Supplement Welding Manual Filler Metals General Welding Procedure Specifications WPSsFiller Metals Demand Critical Welds Filler Metals All D1.8 WeldsSee D1.8, clause Techniques Regarding Production Welding InspectorsRegarding Welder Qualification Regarding Filler MetalsRegarding the Protected Zone Regarding Structural DetailsLincoln Electric Products D1.8 Seismic Supplement Welding Manual Heat Input Limits for Demand Critical Welds Exposure TestingHeat Input Limits for Demand Critical Welds cont’d Appendices Smaw and Gmaw Certificates of Conformance Additional Certificates Available OnlineMetal-Cored Wire Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Meets ALL Requirements of AWS D1.82009 Appendix B Intermix Testing D1.8 Seismic Supplement Welding Manual Appendix C Alternative To Production Lot Testing D1.8 Seismic Supplement Welding Manual D1.8 Seismic Supplement Welding Manual D1.8 Seismic Supplement Welding Manual District Sales Offices Automation Division